{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-6633"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-6633","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Experimental Design for Determining the Cyclic Behavior of Skewed Reduced Beam Section Moment Connections having Composite Slabs","abstract":"This paper details the experimental design for determining the cyclic behavior of skewed Reduced Beam Section (RBS) moment connections having composite slabs. The effects of composite concrete slabs on skewed RBS connections subjected to cyclic seismic prequalification loading are addressed in this test setup. Full-scale double-sided RBS SMF specimens representing both interior and exterior column connections are designed and fabricated in this work. Experimental test fixturing and a lateral load application setup within the existing Grady E. Harvell Civil Engineering Research and Education Center (CEREC) are designed. All cyclic loading protocols required for the prequalification testing are described herein. Prequalification of the skewed SMF specimens requires the application of a total story drift of 0.04 radian before a 20% reduction in plastic moment capacity (Mp).","abstract_html":"This paper details the experimental design for determining the cyclic behavior of skewed Reduced Beam Section (RBS) moment connections having composite slabs. The effects of composite concrete slabs on skewed RBS connections subjected to cyclic seismic prequalification loading are addressed in this test setup. Full-scale double-sided RBS SMF specimens representing both interior and exterior column connections are designed and fabricated in this work. Experimental test fixturing and a lateral load application setup within the existing Grady E. Harvell Civil Engineering Research and Education Center (CEREC) are designed. All cyclic loading protocols required for the prequalification testing are described herein. Prequalification of the skewed SMF specimens requires the application of a total story drift of 0.04 radian before a 20% reduction in plastic moment capacity (Mp).","abstract_has_math":false,"creators":["Chabaud, Paul"],"institution":null,"degree_name":"Master of Science in Civil Engineering (MSCE)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Civil Engineering","school":null,"contributors":["Hale, W. Micah","Selvam, R. Panneer"],"advisors":["Prinz, Gary S."],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-27T02:20:59Z","subjects":["Composite slabs","Cyclic loading protocol","Lateral bracing system","Reduced Beam Section","Skewed connections","Special Moment Frame","Civil Engineering","Structural Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/5080","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/5080","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-6633","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-6633","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hale, W. Micah","Selvam, R. Panneer"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Prinz, Gary S."]},{"key":"dc:creator","label":"Author","values":["Chabaud, Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-05-01T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-05-01T07:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Civil Engineering (MSCE)","M.S.C.E."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Composite slabs","Cyclic loading protocol","Lateral bracing system","Reduced Beam Section","Skewed connections","Special Moment Frame","Civil Engineering","Structural Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/5080"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This paper details the experimental design for determining the cyclic behavior of skewed Reduced Beam Section (RBS) moment connections having composite slabs. The effects of composite concrete slabs on skewed RBS connections subjected to cyclic seismic prequalification loading are addressed in this test setup. Full-scale double-sided RBS SMF specimens representing both interior and exterior column connections are designed and fabricated in this work. Experimental test fixturing and a lateral load application setup within the existing Grady E. Harvell Civil Engineering Research and Education Center (CEREC) are designed. All cyclic loading protocols required for the prequalification testing are described herein. Prequalification of the skewed SMF specimens requires the application of a total story drift of 0.04 radian before a 20% reduction in plastic moment capacity (Mp)."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["86"]},{"key":"dc:title","label":"Title","values":["Experimental Design for Determining the Cyclic Behavior of Skewed Reduced Beam Section Moment Connections having Composite Slabs"]}]}],"canonical_facts":{"dc:contributor":["Hale, W. Micah","Selvam, R. Panneer"],"dc:contributor.advisor":["Prinz, Gary S."],"dc:creator":["Chabaud, Paul"],"dc:date":["2023"],"dc:date.available":["2023-05-01T07:00:00Z"],"dc:date.created":["2023-05-01T07:00:00Z"],"dc:description.abstract":["This paper details the experimental design for determining the cyclic behavior of skewed Reduced Beam Section (RBS) moment connections having composite slabs. The effects of composite concrete slabs on skewed RBS connections subjected to cyclic seismic prequalification loading are addressed in this test setup. Full-scale double-sided RBS SMF specimens representing both interior and exterior column connections are designed and fabricated in this work. Experimental test fixturing and a lateral load application setup within the existing Grady E. Harvell Civil Engineering Research and Education Center (CEREC) are designed. All cyclic loading protocols required for the prequalification testing are described herein. Prequalification of the skewed SMF specimens requires the application of a total story drift of 0.04 radian before a 20% reduction in plastic moment capacity (Mp)."],"dc:format.extent":["86"],"dc:identifier":["https://scholarworks.uark.edu/etd/5080"],"dc:subject":["Composite slabs","Cyclic loading protocol","Lateral bracing system","Reduced Beam Section","Skewed connections","Special Moment Frame","Civil Engineering","Structural Engineering"],"dc:title":["Experimental Design for Determining the Cyclic Behavior of Skewed Reduced Beam Section Moment Connections having Composite Slabs"],"thesis:degree_department":["Civil Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Civil Engineering (MSCE)","M.S.C.E."]},"updated_at":"2026-11-27T02:20:59Z"}