{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-7300"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-7300","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Regulatory Compliance Standards and Power System Reliability: A Study on Inverter-Based Resources","abstract":"The increasing penetration of renewable energy, particularly inverter-based resources (IBRs), has reshaped the dynamics of modern power systems. This thesis investigates the impact of regulatory compliance, especially frequency ride-through requirements under NERC PRC-029-1, on the performance and reliability of interconnected multi-area systems. Using a MATLAB/Simulink-based state-space model built on the foundational structure proposed by Murty [31] and augmented with advanced control methods such as Linear Quadratic Regulator (LQR) control from Mackey and McCann [32] and further refined in the context of IBR damping by Alsarray and McCann [33], we explore three configurations of a three-area load frequency control (LFC) system. These include a baseline scenario with conventional synchronous generators, an IBR scenario without ride-through compliance, and a compliant IBR scenario implementing PRC-029-1 thresholds. Each configuration is tested using a step disturbance in Area 2 to evaluate frequency deviation, power exchange, mechanical output, and control inputs. Simulation results highlight the adverse effects of non-compliant IBRs, including increased frequency instability and the shifting of dynamic burden to remaining synchronous areas. In contrast, compliant IBRs that remain connected during transients significantly improve system damping and maintain inter-area balance. The findings underscore the importance of Reliability Standards in ensuring grid stability amid rising renewable penetration. The study concludes that thoughtful integration of control strategies and compliance logic is instrumental in enabling the reliable operation of future low-inertia power systems.","abstract_html":"The increasing penetration of renewable energy, particularly inverter-based resources (IBRs), has reshaped the dynamics of modern power systems. This thesis investigates the impact of regulatory compliance, especially frequency ride-through requirements under NERC PRC-029-1, on the performance and reliability of interconnected multi-area systems. Using a MATLAB/Simulink-based state-space model built on the foundational structure proposed by Murty [31] and augmented with advanced control methods such as Linear Quadratic Regulator (LQR) control from Mackey and McCann [32] and further refined in the context of IBR damping by Alsarray and McCann [33], we explore three configurations of a three-area load frequency control (LFC) system. These include a baseline scenario with conventional synchronous generators, an IBR scenario without ride-through compliance, and a compliant IBR scenario implementing PRC-029-1 thresholds. Each configuration is tested using a step disturbance in Area 2 to evaluate frequency deviation, power exchange, mechanical output, and control inputs. Simulation results highlight the adverse effects of non-compliant IBRs, including increased frequency instability and the shifting of dynamic burden to remaining synchronous areas. In contrast, compliant IBRs that remain connected during transients significantly improve system damping and maintain inter-area balance. The findings underscore the importance of Reliability Standards in ensuring grid stability amid rising renewable penetration. The study concludes that thoughtful integration of control strategies and compliance logic is instrumental in enabling the reliable operation of future low-inertia power systems.","abstract_has_math":false,"creators":["Honarmand, Pirouz"],"institution":null,"degree_name":"Master of Science in Electrical Engineering (MSEE)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Electrical Engineering and Computer Science","school":null,"contributors":["Younes Velosa, Camilo","Wu, Jingxian"],"advisors":["McCann, Roy A."],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-27T02:21:18Z","subjects":["Inverter-Based Resources","Regulatory","Reliability","Reliability Standards","Stability","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/5747","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/5747","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-7300","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-7300","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Younes Velosa, Camilo","Wu, Jingxian"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["McCann, Roy A."]},{"key":"dc:creator","label":"Author","values":["Honarmand, Pirouz"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-05-01T07:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical Engineering and Computer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering (MSEE)","M.S.E.E."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Inverter-Based Resources","Regulatory","Reliability","Reliability Standards","Stability","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/5747"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The increasing penetration of renewable energy, particularly inverter-based resources (IBRs), has reshaped the dynamics of modern power systems. This thesis investigates the impact of regulatory compliance, especially frequency ride-through requirements under NERC PRC-029-1, on the performance and reliability of interconnected multi-area systems. Using a MATLAB/Simulink-based state-space model built on the foundational structure proposed by Murty [31] and augmented with advanced control methods such as Linear Quadratic Regulator (LQR) control from Mackey and McCann [32] and further refined in the context of IBR damping by Alsarray and McCann [33], we explore three configurations of a three-area load frequency control (LFC) system. These include a baseline scenario with conventional synchronous generators, an IBR scenario without ride-through compliance, and a compliant IBR scenario implementing PRC-029-1 thresholds. Each configuration is tested using a step disturbance in Area 2 to evaluate frequency deviation, power exchange, mechanical output, and control inputs. Simulation results highlight the adverse effects of non-compliant IBRs, including increased frequency instability and the shifting of dynamic burden to remaining synchronous areas. In contrast, compliant IBRs that remain connected during transients significantly improve system damping and maintain inter-area balance. The findings underscore the importance of Reliability Standards in ensuring grid stability amid rising renewable penetration. The study concludes that thoughtful integration of control strategies and compliance logic is instrumental in enabling the reliable operation of future low-inertia power systems."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["61"]},{"key":"dc:title","label":"Title","values":["Regulatory Compliance Standards and Power System Reliability: A Study on Inverter-Based Resources"]}]}],"canonical_facts":{"dc:contributor":["Younes Velosa, Camilo","Wu, Jingxian"],"dc:contributor.advisor":["McCann, Roy A."],"dc:creator":["Honarmand, Pirouz"],"dc:date":["2025"],"dc:date.created":["2025-05-01T07:00:00Z"],"dc:description.abstract":["The increasing penetration of renewable energy, particularly inverter-based resources (IBRs), has reshaped the dynamics of modern power systems. This thesis investigates the impact of regulatory compliance, especially frequency ride-through requirements under NERC PRC-029-1, on the performance and reliability of interconnected multi-area systems. Using a MATLAB/Simulink-based state-space model built on the foundational structure proposed by Murty [31] and augmented with advanced control methods such as Linear Quadratic Regulator (LQR) control from Mackey and McCann [32] and further refined in the context of IBR damping by Alsarray and McCann [33], we explore three configurations of a three-area load frequency control (LFC) system. These include a baseline scenario with conventional synchronous generators, an IBR scenario without ride-through compliance, and a compliant IBR scenario implementing PRC-029-1 thresholds. Each configuration is tested using a step disturbance in Area 2 to evaluate frequency deviation, power exchange, mechanical output, and control inputs. Simulation results highlight the adverse effects of non-compliant IBRs, including increased frequency instability and the shifting of dynamic burden to remaining synchronous areas. In contrast, compliant IBRs that remain connected during transients significantly improve system damping and maintain inter-area balance. The findings underscore the importance of Reliability Standards in ensuring grid stability amid rising renewable penetration. The study concludes that thoughtful integration of control strategies and compliance logic is instrumental in enabling the reliable operation of future low-inertia power systems."],"dc:format.extent":["61"],"dc:identifier":["https://scholarworks.uark.edu/etd/5747"],"dc:subject":["Inverter-Based Resources","Regulatory","Reliability","Reliability Standards","Stability","Engineering"],"dc:title":["Regulatory Compliance Standards and Power System Reliability: A Study on Inverter-Based Resources"],"thesis:degree_department":["Electrical Engineering and Computer Science"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Electrical Engineering (MSEE)","M.S.E.E."]},"updated_at":"2026-11-27T02:21:18Z"}