{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-7484"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-7484","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Advancing Point-of-Care Diagnosis of Joint Infection Using a Diffuse Reflectance Spectroscopy (DRS) System","abstract":"Septic arthritis is a severe joint infection that can rapidly destroy cartilage and cause lifelong disability if not diagnosed and treated promptly. Faster, bedside diagnostic tools are needed to reduce delays and support timely treatment decisions while preserving standard laboratory workflows. A syringe-mounted diffuse reflectance spectroscopy (DRS) system was developed for rapid, sterile, point-of-care measurement of synovial fluid optical properties. Broadband light (400–650 nm) was delivered and collected through the syringe barrel without contaminating the sample. An empirical lookup table (LUT) and a boundary-aware Monte Carlo (MC) model were implemented to extract absorption (μₐ) and reduced scattering (μs′) coefficients from the measured spectra. Optical phantom studies confirmed that the system retrieves optical properties within 5–15% of known reference values and achieves signal-to-noise ratios exceeding 50 dB. Prospective patient samples (n = 19) demonstrated that scattering amplitude and reflectance band ratios (e.g., R₄₉₀/R₆₀₀) distinguish infected from non-infected fluid with ≥85% sensitivity and ≥90% specificity in under five minutes. The non-contact design preserves fluid sterility for culture confirmation. This work demonstrates a practical path from proof-of-concept to deployable point-of-care optical screening for septic arthritis, supporting faster treatment decisions and improved patient outcomes.","abstract_html":"Septic arthritis is a severe joint infection that can rapidly destroy cartilage and cause lifelong disability if not diagnosed and treated promptly. Faster, bedside diagnostic tools are needed to reduce delays and support timely treatment decisions while preserving standard laboratory workflows. A syringe-mounted diffuse reflectance spectroscopy (DRS) system was developed for rapid, sterile, point-of-care measurement of synovial fluid optical properties. Broadband light (400–650 nm) was delivered and collected through the syringe barrel without contaminating the sample. An empirical lookup table (LUT) and a boundary-aware Monte Carlo (MC) model were implemented to extract absorption (μₐ) and reduced scattering (μs′) coefficients from the measured spectra. Optical phantom studies confirmed that the system retrieves optical properties within 5–15% of known reference values and achieves signal-to-noise ratios exceeding 50 dB. Prospective patient samples (n = 19) demonstrated that scattering amplitude and reflectance band ratios (e.g., R₄₉₀/R₆₀₀) distinguish infected from non-infected fluid with ≥85% sensitivity and ≥90% specificity in under five minutes. The non-contact design preserves fluid sterility for culture confirmation. This work demonstrates a practical path from proof-of-concept to deployable point-of-care optical screening for septic arthritis, supporting faster treatment decisions and improved patient outcomes.","abstract_has_math":false,"creators":["Drewke, Erin Elizabeth"],"institution":null,"degree_name":"Doctor of Philosophy in Engineering (PhD)","degree_level":"Dissertation","degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":["Jensen, Hanna","Wolchok, Jeffery"],"advisors":["Rajaram, Narasimhan"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-27T02:21:18Z","subjects":["Diffuse Reflectance","Infection","Lookup Table","Monte Carlo","Optics","Synovial Fluid","Analytical, Diagnostic and Therapeutic Techniques and Equipment"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/5931","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/5931","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-7484","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-7484","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jensen, Hanna","Wolchok, Jeffery"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Rajaram, Narasimhan"]},{"key":"dc:creator","label":"Author","values":["Drewke, Erin Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-16T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-08-01T07:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy in Engineering (PhD)","(Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Diffuse Reflectance","Infection","Lookup Table","Monte Carlo","Optics","Synovial Fluid","Analytical, Diagnostic and Therapeutic Techniques and Equipment"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/5931"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Septic arthritis is a severe joint infection that can rapidly destroy cartilage and cause lifelong disability if not diagnosed and treated promptly. Faster, bedside diagnostic tools are needed to reduce delays and support timely treatment decisions while preserving standard laboratory workflows. A syringe-mounted diffuse reflectance spectroscopy (DRS) system was developed for rapid, sterile, point-of-care measurement of synovial fluid optical properties. Broadband light (400–650 nm) was delivered and collected through the syringe barrel without contaminating the sample. An empirical lookup table (LUT) and a boundary-aware Monte Carlo (MC) model were implemented to extract absorption (μₐ) and reduced scattering (μs′) coefficients from the measured spectra. Optical phantom studies confirmed that the system retrieves optical properties within 5–15% of known reference values and achieves signal-to-noise ratios exceeding 50 dB. Prospective patient samples (n = 19) demonstrated that scattering amplitude and reflectance band ratios (e.g., R₄₉₀/R₆₀₀) distinguish infected from non-infected fluid with ≥85% sensitivity and ≥90% specificity in under five minutes. The non-contact design preserves fluid sterility for culture confirmation. This work demonstrates a practical path from proof-of-concept to deployable point-of-care optical screening for septic arthritis, supporting faster treatment decisions and improved patient outcomes."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["124"]},{"key":"dc:title","label":"Title","values":["Advancing Point-of-Care Diagnosis of Joint Infection Using a Diffuse Reflectance Spectroscopy (DRS) System"]}]}],"canonical_facts":{"dc:contributor":["Jensen, Hanna","Wolchok, Jeffery"],"dc:contributor.advisor":["Rajaram, Narasimhan"],"dc:creator":["Drewke, Erin Elizabeth"],"dc:date":["2025"],"dc:date.available":["2025-12-16T08:00:00Z"],"dc:date.created":["2025-08-01T07:00:00Z"],"dc:description.abstract":["Septic arthritis is a severe joint infection that can rapidly destroy cartilage and cause lifelong disability if not diagnosed and treated promptly. Faster, bedside diagnostic tools are needed to reduce delays and support timely treatment decisions while preserving standard laboratory workflows. A syringe-mounted diffuse reflectance spectroscopy (DRS) system was developed for rapid, sterile, point-of-care measurement of synovial fluid optical properties. Broadband light (400–650 nm) was delivered and collected through the syringe barrel without contaminating the sample. An empirical lookup table (LUT) and a boundary-aware Monte Carlo (MC) model were implemented to extract absorption (μₐ) and reduced scattering (μs′) coefficients from the measured spectra. Optical phantom studies confirmed that the system retrieves optical properties within 5–15% of known reference values and achieves signal-to-noise ratios exceeding 50 dB. Prospective patient samples (n = 19) demonstrated that scattering amplitude and reflectance band ratios (e.g., R₄₉₀/R₆₀₀) distinguish infected from non-infected fluid with ≥85% sensitivity and ≥90% specificity in under five minutes. The non-contact design preserves fluid sterility for culture confirmation. This work demonstrates a practical path from proof-of-concept to deployable point-of-care optical screening for septic arthritis, supporting faster treatment decisions and improved patient outcomes."],"dc:format.extent":["124"],"dc:identifier":["https://scholarworks.uark.edu/etd/5931"],"dc:subject":["Diffuse Reflectance","Infection","Lookup Table","Monte Carlo","Optics","Synovial Fluid","Analytical, Diagnostic and Therapeutic Techniques and Equipment"],"dc:title":["Advancing Point-of-Care Diagnosis of Joint Infection Using a Diffuse Reflectance Spectroscopy (DRS) System"],"thesis:degree_department":["Biomedical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy in Engineering (PhD)","(Ph.D.)"]},"updated_at":"2026-11-27T02:21:18Z"}