{"id":{"repo_id":"arkansas","oai_identifier":"oai:scholarworks.uark.edu:etd-7602"},"canonical_url":"https://search.ndltd.org/etd/arkansas/oai:scholarworks.uark.edu:etd-7602","repository":{"repo_id":"arkansas","name":"University of Arkansas","base_url":"https://scholarworks.uark.edu/do/oai/"},"display":{"title":"Design and Development of a Multi-Port Solid State Circuit Breaker Based on Half Bridge SiC MOSFETs","abstract":"This thesis investigates multi-port solid-state circuit breaker (M-SSCB) architectures that reduce steady-state conduction losses while preserving microsecond-class DC fault interruption and per-port selectivity. The proposed M-SSCB consolidates protection for several node interfaces into a single assembly with shared sensing, control, and a common energy-absorption branch. In normal operation, two electrically symmetric parallel semiconductor paths are established so each port’s current divides approximately in half; because conduction loss scales with current squared, the M-SSCB achieves ≈75% reduction in on-state loss relative to a conventional anti-series SiC path without increasing device count. During fault handling, the coordinated controller detects the local over-current, commutates the fault into the shared energy absorption branch, bounds the overvoltage, and maintains service on healthy ports; in this transient/post-fault window the baseline M-SSCB provides up to ≈50% loss reduction compared to the conventional path. To preserve the full benefit after a trip, a modified M-SSCB integrates per-port, zero-current-opened mechanical isolators and a simple reconfiguration routine that, once the faulty branch is opened, restores and maintains the ≈75% conduction-loss reduction even in post-fault operation. Analysis, time-domain simulations with device-level models, and a three-port prototype (400 VDC, 30 A/port, 1200 V SiC, tripping current 60 A) demonstrate fast clearing, bounded clamped voltage, per-port selectivity, and automatic recovery of the low-loss state on unfaulty ports, indicating that the M-SSCB family can meet DC protection speed targets while materially lowering day-to-day losses at the node.","abstract_html":"This thesis investigates multi-port solid-state circuit breaker (M-SSCB) architectures that reduce steady-state conduction losses while preserving microsecond-class DC fault interruption and per-port selectivity. The proposed M-SSCB consolidates protection for several node interfaces into a single assembly with shared sensing, control, and a common energy-absorption branch. In normal operation, two electrically symmetric parallel semiconductor paths are established so each port’s current divides approximately in half; because conduction loss scales with current squared, the M-SSCB achieves ≈75% reduction in on-state loss relative to a conventional anti-series SiC path without increasing device count. During fault handling, the coordinated controller detects the local over-current, commutates the fault into the shared energy absorption branch, bounds the overvoltage, and maintains service on healthy ports; in this transient/post-fault window the baseline M-SSCB provides up to ≈50% loss reduction compared to the conventional path. To preserve the full benefit after a trip, a modified M-SSCB integrates per-port, zero-current-opened mechanical isolators and a simple reconfiguration routine that, once the faulty branch is opened, restores and maintains the ≈75% conduction-loss reduction even in post-fault operation. Analysis, time-domain simulations with device-level models, and a three-port prototype (400 VDC, 30 A/port, 1200 V SiC, tripping current 60 A) demonstrate fast clearing, bounded clamped voltage, per-port selectivity, and automatic recovery of the low-loss state on unfaulty ports, indicating that the M-SSCB family can meet DC protection speed targets while materially lowering day-to-day losses at the node.","abstract_has_math":false,"creators":["Nawafleh, Yannal"],"institution":null,"degree_name":"Master of Science in Electrical Engineering (MSEE)","degree_level":"Thesis","degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":["McCann, Roy","Zhao, Yue"],"advisors":["Song, Xiaoqing"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-27T02:21:18Z","subjects":["Conduction loss","Multi-port SSCB","SiC MOSFET","Solid state circuit breaker","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.uark.edu/etd/6037","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.uark.edu/etd/6037","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aarkansas%3Aoai%3Ascholarworks.uark.edu%3Aetd-7602","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.uark.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.uark.edu%3Aetd-7602","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["McCann, Roy","Zhao, Yue"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Song, Xiaoqing"]},{"key":"dc:creator","label":"Author","values":["Nawafleh, Yannal"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-12-01T08:00:00Z"]},{"key":"thesis:degree_department","label":"Department","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering (MSEE)","MSEE"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Conduction loss","Multi-port SSCB","SiC MOSFET","Solid state circuit breaker","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.uark.edu/etd/6037"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis investigates multi-port solid-state circuit breaker (M-SSCB) architectures that reduce steady-state conduction losses while preserving microsecond-class DC fault interruption and per-port selectivity. The proposed M-SSCB consolidates protection for several node interfaces into a single assembly with shared sensing, control, and a common energy-absorption branch. In normal operation, two electrically symmetric parallel semiconductor paths are established so each port’s current divides approximately in half; because conduction loss scales with current squared, the M-SSCB achieves ≈75% reduction in on-state loss relative to a conventional anti-series SiC path without increasing device count. During fault handling, the coordinated controller detects the local over-current, commutates the fault into the shared energy absorption branch, bounds the overvoltage, and maintains service on healthy ports; in this transient/post-fault window the baseline M-SSCB provides up to ≈50% loss reduction compared to the conventional path. To preserve the full benefit after a trip, a modified M-SSCB integrates per-port, zero-current-opened mechanical isolators and a simple reconfiguration routine that, once the faulty branch is opened, restores and maintains the ≈75% conduction-loss reduction even in post-fault operation. Analysis, time-domain simulations with device-level models, and a three-port prototype (400 VDC, 30 A/port, 1200 V SiC, tripping current 60 A) demonstrate fast clearing, bounded clamped voltage, per-port selectivity, and automatic recovery of the low-loss state on unfaulty ports, indicating that the M-SSCB family can meet DC protection speed targets while materially lowering day-to-day losses at the node."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["57"]},{"key":"dc:title","label":"Title","values":["Design and Development of a Multi-Port Solid State Circuit Breaker Based on Half Bridge SiC MOSFETs"]}]}],"canonical_facts":{"dc:contributor":["McCann, Roy","Zhao, Yue"],"dc:contributor.advisor":["Song, Xiaoqing"],"dc:creator":["Nawafleh, Yannal"],"dc:date":["2025"],"dc:date.available":["2020-01-01T08:00:00Z"],"dc:date.created":["2025-12-01T08:00:00Z"],"dc:description.abstract":["This thesis investigates multi-port solid-state circuit breaker (M-SSCB) architectures that reduce steady-state conduction losses while preserving microsecond-class DC fault interruption and per-port selectivity. The proposed M-SSCB consolidates protection for several node interfaces into a single assembly with shared sensing, control, and a common energy-absorption branch. In normal operation, two electrically symmetric parallel semiconductor paths are established so each port’s current divides approximately in half; because conduction loss scales with current squared, the M-SSCB achieves ≈75% reduction in on-state loss relative to a conventional anti-series SiC path without increasing device count. During fault handling, the coordinated controller detects the local over-current, commutates the fault into the shared energy absorption branch, bounds the overvoltage, and maintains service on healthy ports; in this transient/post-fault window the baseline M-SSCB provides up to ≈50% loss reduction compared to the conventional path. To preserve the full benefit after a trip, a modified M-SSCB integrates per-port, zero-current-opened mechanical isolators and a simple reconfiguration routine that, once the faulty branch is opened, restores and maintains the ≈75% conduction-loss reduction even in post-fault operation. Analysis, time-domain simulations with device-level models, and a three-port prototype (400 VDC, 30 A/port, 1200 V SiC, tripping current 60 A) demonstrate fast clearing, bounded clamped voltage, per-port selectivity, and automatic recovery of the low-loss state on unfaulty ports, indicating that the M-SSCB family can meet DC protection speed targets while materially lowering day-to-day losses at the node."],"dc:format.extent":["57"],"dc:identifier":["https://scholarworks.uark.edu/etd/6037"],"dc:subject":["Conduction loss","Multi-port SSCB","SiC MOSFET","Solid state circuit breaker","Engineering"],"dc:title":["Design and Development of a Multi-Port Solid State Circuit Breaker Based on Half Bridge SiC MOSFETs"],"thesis:degree_department":["Electrical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Master of Science in Electrical Engineering (MSEE)","MSEE"]},"updated_at":"2026-11-27T02:21:18Z"}