{"id":{"repo_id":"aston","oai_identifier":"oai:publications.aston.ac.uk:10162"},"canonical_url":"https://search.ndltd.org/etd/aston/oai:publications.aston.ac.uk:10162","repository":{"repo_id":"aston","name":"Aston University","base_url":"https://publications.aston.ac.uk/cgi/oai2"},"display":{"title":"Maintenance strategies affecting equipment performance","abstract":"Proper maintenance of plant items is crucial for the safe and profitable operation of process plants, The relevant maintenance policies fall into the following four categories: (i) preventivejopportunistic/breakdown replacement policies, (ii) inspection/inspection-repair-replacernent policies, (iii) restorative maintenance policies, and (iv) condition based maintenance policies, For correlating failure times of component equipnent and complete systems, the Weibull failure distribution has been used, A new powerful method, SEQLIM, has been proposed for the estimation of the Weibull parameters; particularly, when maintenance records contain very few failures and many successful operation times. When a system consists of a number of replaceable, ageing components, an opporturistic replacernent policy has been found to be cost-effective, A simple opportunistic rrodel has been developed. Inspection models with various objective functions have been investigated, It was found that, on the assumption of a negative exponential failure distribution, all models converge to the same optimal inspection interval; provided the safety components are very reliable and the demand rate is low, When deterioration becomes a contributory factor to same failures, periodic inspections, calculated from above models, are too frequent, A case of safety trip systems has been studied, A highly effective restorative maintenance policy can be developed if the performance of the equipment under this category can be related to some predictive modelling. A novel fouling model has been proposed to determine cleaning strategies of condensers, Condition-based maintenance policies have been investigated. A simple gauge has been designed for condition monitoring of relief valve springs. A typical case of an exothermic inert gas generation plant has been studied, to demonstrate how various policies can be applied to devise overall maintenance actions.","abstract_html":"Proper maintenance of plant items is crucial for the safe and profitable operation of process plants, The relevant maintenance policies fall into the following four categories: (i) preventivejopportunistic/breakdown replacement policies, (ii) inspection/inspection-repair-replacernent policies, (iii) restorative maintenance policies, and (iv) condition based maintenance policies, For correlating failure times of component equipnent and complete systems, the Weibull failure distribution has been used, A new powerful method, SEQLIM, has been proposed for the estimation of the Weibull parameters; particularly, when maintenance records contain very few failures and many successful operation times. When a system consists of a number of replaceable, ageing components, an opporturistic replacernent policy has been found to be cost-effective, A simple opportunistic rrodel has been developed. Inspection models with various objective functions have been investigated, It was found that, on the assumption of a negative exponential failure distribution, all models converge to the same optimal inspection interval; provided the safety components are very reliable and the demand rate is low, When deterioration becomes a contributory factor to same failures, periodic inspections, calculated from above models, are too frequent, A case of safety trip systems has been studied, A highly effective restorative maintenance policy can be developed if the performance of the equipment under this category can be related to some predictive modelling. A novel fouling model has been proposed to determine cleaning strategies of condensers, Condition-based maintenance policies have been investigated. A simple gauge has been designed for condition monitoring of relief valve springs. A typical case of an exothermic inert gas generation plant has been studied, to demonstrate how various policies can be applied to devise overall maintenance actions.","abstract_has_math":false,"creators":["Kabir, A.B.M.Z."],"institution":"Aston University","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1980,"date_issued":"1980-10","date_published":"1980-10","updated_at":"2026-11-25T19:45:29Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://publications.aston.ac.uk/id/eprint/10162/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://publications.aston.ac.uk/id/eprint/10162/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aaston%3Aoai%3Apublications.aston.ac.uk%3A10162","prefix":"oai_dc"},"source_record":{"url":"https://publications.aston.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Apublications.aston.ac.uk%3A10162","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kabir, A.B.M.Z."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1980-10"]},{"key":"dc:date.issued","label":"Date","values":["1980-10"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Chemical Engineering & Applied Chemistry"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Aston University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://publications.aston.ac.uk/id/eprint/10162/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Proper maintenance of plant items is crucial for the safe and profitable operation of process plants, The relevant maintenance policies fall into the following four categories: (i) preventivejopportunistic/breakdown replacement policies, (ii) inspection/inspection-repair-replacernent policies, (iii) restorative maintenance policies, and (iv) condition based maintenance policies, For correlating failure times of component equipnent and complete systems, the Weibull failure distribution has been used, A new powerful method, SEQLIM, has been proposed for the estimation of the Weibull parameters; particularly, when maintenance records contain very few failures and many successful operation times. When a system consists of a number of replaceable, ageing components, an opporturistic replacernent policy has been found to be cost-effective, A simple opportunistic rrodel has been developed. Inspection models with various objective functions have been investigated, It was found that, on the assumption of a negative exponential failure distribution, all models converge to the same optimal inspection interval; provided the safety components are very reliable and the demand rate is low, When deterioration becomes a contributory factor to same failures, periodic inspections, calculated from above models, are too frequent, A case of safety trip systems has been studied, A highly effective restorative maintenance policy can be developed if the performance of the equipment under this category can be related to some predictive modelling. A novel fouling model has been proposed to determine cleaning strategies of condensers, Condition-based maintenance policies have been investigated. A simple gauge has been designed for condition monitoring of relief valve springs. A typical case of an exothermic inert gas generation plant has been studied, to demonstrate how various policies can be applied to devise overall maintenance actions."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Maintenance strategies affecting equipment performance"]}]}],"canonical_facts":{"dc:creator":["Kabir, A.B.M.Z."],"dc:date":["1980-10"],"dc:date.issued":["1980-10"],"dc:description.abstract":["Proper maintenance of plant items is crucial for the safe and profitable operation of process plants, The relevant maintenance policies fall into the following four categories: (i) preventivejopportunistic/breakdown replacement policies, (ii) inspection/inspection-repair-replacernent policies, (iii) restorative maintenance policies, and (iv) condition based maintenance policies, For correlating failure times of component equipnent and complete systems, the Weibull failure distribution has been used, A new powerful method, SEQLIM, has been proposed for the estimation of the Weibull parameters; particularly, when maintenance records contain very few failures and many successful operation times. When a system consists of a number of replaceable, ageing components, an opporturistic replacernent policy has been found to be cost-effective, A simple opportunistic rrodel has been developed. Inspection models with various objective functions have been investigated, It was found that, on the assumption of a negative exponential failure distribution, all models converge to the same optimal inspection interval; provided the safety components are very reliable and the demand rate is low, When deterioration becomes a contributory factor to same failures, periodic inspections, calculated from above models, are too frequent, A case of safety trip systems has been studied, A highly effective restorative maintenance policy can be developed if the performance of the equipment under this category can be related to some predictive modelling. A novel fouling model has been proposed to determine cleaning strategies of condensers, Condition-based maintenance policies have been investigated. A simple gauge has been designed for condition monitoring of relief valve springs. A typical case of an exothermic inert gas generation plant has been studied, to demonstrate how various policies can be applied to devise overall maintenance actions."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://publications.aston.ac.uk/id/eprint/10162/"],"dc:publisher.department":["Chemical Engineering & Applied Chemistry"],"dc:publisher.institution":["Aston University"],"dcterms:accessrights":["public"],"dc:title":["Maintenance strategies affecting equipment performance"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-25T19:45:29Z"}