{"id":{"repo_id":"aston","oai_identifier":"oai:publications.aston.ac.uk:12044"},"canonical_url":"https://search.ndltd.org/etd/aston/oai:publications.aston.ac.uk:12044","repository":{"repo_id":"aston","name":"Aston University","base_url":"https://publications.aston.ac.uk/cgi/oai2"},"display":{"title":"The Measurement of Ti (n,p) Sc and Ni (n,p) Co Reaction Cross-sections in the Energy Range 3.5 MeV to 5.5 MeV","abstract":"The measurement of neutron cross-sections for 46,47 Ti (n,p) 46, 47 Sc, 58 Ni (n,p) 58Co and 29Si(n,α) 26Mg reactions has been performed relative to the 238 U (n,f) cross-section in the neutron energy range of 3.5 MeV to 5.5 MeV. The neutron source was a deuterium gas target, employing the D(d,n)3 He reaction. The neutron flux measurements were made with a low mass parallel-plate ionisation chamber, to detect the fission fragments from the 238U standard. The 238U content of the fission foil was determined using an alpha particle assaying technique. A surface barrier silicon detector was used for the on-line detection of charged particles from titanium and nickel foils. Initially, an inert gas scintillation detector was developed to avoid using a silicon detector, but the technique proved unsuccessful owing to the high gamma-radiation sensitivity of the scintillator. A Monte Carlo program was applied to determine neutron beam profile from the gas target and to determine the irradiation geometry of sample and fission foil. The measured cross-section data show good agreement with some previously reported measurements and meet the accuracy requirements of recent data requests.","abstract_html":"The measurement of neutron cross-sections for 46,47 Ti (n,p) 46, 47 Sc, 58 Ni (n,p) 58Co and 29Si(n,α) 26Mg reactions has been performed relative to the 238 U (n,f) cross-section in the neutron energy range of 3.5 MeV to 5.5 MeV. The neutron source was a deuterium gas target, employing the D(d,n)3 He reaction. The neutron flux measurements were made with a low mass parallel-plate ionisation chamber, to detect the fission fragments from the 238U standard. The 238U content of the fission foil was determined using an alpha particle assaying technique. A surface barrier silicon detector was used for the on-line detection of charged particles from titanium and nickel foils. Initially, an inert gas scintillation detector was developed to avoid using a silicon detector, but the technique proved unsuccessful owing to the high gamma-radiation sensitivity of the scintillator. A Monte Carlo program was applied to determine neutron beam profile from the gas target and to determine the irradiation geometry of sample and fission foil. The measured cross-section data show good agreement with some previously reported measurements and meet the accuracy requirements of recent data requests.","abstract_has_math":false,"creators":["Bunger, Charan S."],"institution":"Aston University","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1983,"date_issued":"1983-03","date_published":"1983-03","updated_at":"2026-11-25T19:47:22Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://publications.aston.ac.uk/id/eprint/12044/"],"render_values":[{"text":"https://publications.aston.ac.uk/id/eprint/12044/","href":"https://publications.aston.ac.uk/id/eprint/12044/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.48780/publications.aston.ac.uk.00012044","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.48780/publications.aston.ac.uk.00012044","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aaston%3Aoai%3Apublications.aston.ac.uk%3A12044","prefix":"oai_dc"},"source_record":{"url":"https://publications.aston.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Apublications.aston.ac.uk%3A12044","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bunger, Charan S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1983-03"]},{"key":"dc:date.issued","label":"Date","values":["1983-03"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Aston University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.48780/publications.aston.ac.uk.00012044"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://publications.aston.ac.uk/id/eprint/12044/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The measurement of neutron cross-sections for 46,47 Ti (n,p) 46, 47 Sc, 58 Ni (n,p) 58Co and 29Si(n,α) 26Mg reactions has been performed relative to the 238 U (n,f) cross-section in the neutron energy range of 3.5 MeV to 5.5 MeV. The neutron source was a deuterium gas target, employing the D(d,n)3 He reaction. The neutron flux measurements were made with a low mass parallel-plate ionisation chamber, to detect the fission fragments from the 238U standard. The 238U content of the fission foil was determined using an alpha particle assaying technique. A surface barrier silicon detector was used for the on-line detection of charged particles from titanium and nickel foils. Initially, an inert gas scintillation detector was developed to avoid using a silicon detector, but the technique proved unsuccessful owing to the high gamma-radiation sensitivity of the scintillator. A Monte Carlo program was applied to determine neutron beam profile from the gas target and to determine the irradiation geometry of sample and fission foil. The measured cross-section data show good agreement with some previously reported measurements and meet the accuracy requirements of recent data requests."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["The Measurement of Ti (n,p) Sc and Ni (n,p) Co Reaction Cross-sections in the Energy Range 3.5 MeV to 5.5 MeV"]}]}],"canonical_facts":{"dc:creator":["Bunger, Charan S."],"dc:date":["1983-03"],"dc:date.issued":["1983-03"],"dc:description.abstract":["The measurement of neutron cross-sections for 46,47 Ti (n,p) 46, 47 Sc, 58 Ni (n,p) 58Co and 29Si(n,α) 26Mg reactions has been performed relative to the 238 U (n,f) cross-section in the neutron energy range of 3.5 MeV to 5.5 MeV. The neutron source was a deuterium gas target, employing the D(d,n)3 He reaction. The neutron flux measurements were made with a low mass parallel-plate ionisation chamber, to detect the fission fragments from the 238U standard. The 238U content of the fission foil was determined using an alpha particle assaying technique. A surface barrier silicon detector was used for the on-line detection of charged particles from titanium and nickel foils. Initially, an inert gas scintillation detector was developed to avoid using a silicon detector, but the technique proved unsuccessful owing to the high gamma-radiation sensitivity of the scintillator. A Monte Carlo program was applied to determine neutron beam profile from the gas target and to determine the irradiation geometry of sample and fission foil. The measured cross-section data show good agreement with some previously reported measurements and meet the accuracy requirements of recent data requests."],"dc:format":["text"],"dc:identifier.doi":["10.48780/publications.aston.ac.uk.00012044"],"dc:identifier.uri":["https://publications.aston.ac.uk/id/eprint/12044/"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences"],"dc:publisher.institution":["Aston University"],"dcterms:accessrights":["public"],"dc:title":["The Measurement of Ti (n,p) Sc and Ni (n,p) Co Reaction Cross-sections in the Energy Range 3.5 MeV to 5.5 MeV"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-11-25T19:47:22Z"}