{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/10177"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/10177","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Chord length methods for proton computed tomography.","abstract":"Proton Computed Tomography (also known as pCT) is an emerging medical imaging method. The three dimensional images reconstructed from pCT scans provide information about the Relative Stopping Power of the object scanned. Proton and ion therapies can administer radiation with higher conformity than traditional photon therapies. The RSP values provided by pCT scans are particularly useful when planning proton and ion related therapies. pCT reconstructions depend on solving the linear system of equations represented by Ax=b. It is necessary to accurately construct the matrix A by determining its elements. Which elements in A are non-zero is determined by Most Likely Path methods. The values of these non-zero elements are known as chord lengths. This work investigates different methods for determining chord length, and the effect they have on pCT reconstructions.","abstract_html":"Proton Computed Tomography (also known as pCT) is an emerging medical imaging method. The three dimensional images reconstructed from pCT scans provide information about the Relative Stopping Power of the object scanned. Proton and ion therapies can administer radiation with higher conformity than traditional photon therapies. The RSP values provided by pCT scans are particularly useful when planning proton and ion related therapies. pCT reconstructions depend on solving the linear system of equations represented by Ax=b. It is necessary to accurately construct the matrix A by determining its elements. Which elements in A are non-zero is determined by Most Likely Path methods. The values of these non-zero elements are known as chord lengths. This work investigates different methods for determining chord length, and the effect they have on pCT reconstructions.","abstract_has_math":false,"creators":["Stenson, John P., 1993-"],"institution":"Baylor University.","degree_name":"M.S.B.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Schubert, Keith Evan."],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-12","date_published":"2017-12","updated_at":"2026-11-22T16:25:33Z","subjects":["Proton Computed Tomography (pCT)","Protons.","Computed Tomography (CT) chord length.","Reconstruction techniques."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/10177","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/10177","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F10177","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F10177","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Schubert, Keith Evan."]},{"key":"dc:creator","label":"Author","values":["Stenson, John P., 1993-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-25T14:02:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-25T14:02:37Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2017"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2017-12"]},{"key":"dc:date.issued","label":"Date","values":["2017-12"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-01-25T14:02:38Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.B.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Proton Computed Tomography (pCT)","Protons.","Computed Tomography (CT) chord length.","Reconstruction techniques."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/10177"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Proton Computed Tomography (also known as pCT) is an emerging medical imaging method. The three dimensional images reconstructed from pCT scans provide information about the Relative Stopping Power of the object scanned. Proton and ion therapies can administer radiation with higher conformity than traditional photon therapies. The RSP values provided by pCT scans are particularly useful when planning proton and ion related therapies. pCT reconstructions depend on solving the linear system of equations represented by Ax=b. It is necessary to accurately construct the matrix A by determining its elements. Which elements in A are non-zero is determined by Most Likely Path methods. The values of these non-zero elements are known as chord lengths. This work investigates different methods for determining chord length, and the effect they have on pCT reconstructions."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Chord length methods for proton computed tomography."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Schubert, Keith Evan."],"dc:creator":["Stenson, John P., 1993-"],"dc:date.accessioned":["2018-01-25T14:02:37Z"],"dc:date.available":["2018-01-25T14:02:37Z"],"dc:date.copyright":["2017"],"dc:date.created":["2017-12"],"dc:date.issued":["2017-12"],"dc:date.submitted":["December 2017"],"dc:date.updated":["2018-01-25T14:02:38Z"],"dc:description.abstract":["Proton Computed Tomography (also known as pCT) is an emerging medical imaging method. The three dimensional images reconstructed from pCT scans provide information about the Relative Stopping Power of the object scanned. Proton and ion therapies can administer radiation with higher conformity than traditional photon therapies. The RSP values provided by pCT scans are particularly useful when planning proton and ion related therapies. pCT reconstructions depend on solving the linear system of equations represented by Ax=b. It is necessary to accurately construct the matrix A by determining its elements. Which elements in A are non-zero is determined by Most Likely Path methods. The values of these non-zero elements are known as chord lengths. This work investigates different methods for determining chord length, and the effect they have on pCT reconstructions."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/10177"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Proton Computed Tomography (pCT)","Protons.","Computed Tomography (CT) chord length.","Reconstruction techniques."],"dc:title":["Chord length methods for proton computed tomography."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.B.M.E."],"thesis:degree_program":["Biomedical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:25:33Z"}