{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/10370"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/10370","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Effect of inlet hole geometry on surface film cooling effectiveness from compound angle, shaped holes.","abstract":"The gas turbine engine operates at temperatures that far exceed the melting point of the metals from which they are made. Cooling air from the high pressure compressor must be used to cool the components in the hot sections of the turbine engines. Coolant must be used as effectively as possible in order to increase engine efficiency. The Pressure Sensitive Paint technique (PSP) is used to evaluate the effects of both compound angles and advanced shapes on the film cooling effectiveness. Most current film cooling geometries are orientated streamwise, with mainstream flow, and the addition of the compound angle has shown to both positive and negative effects on cooling effectiveness. These changes are seen based on the type of inlet, cooling geometry, and expansion of the outlet geometry onto the surface.","abstract_html":"The gas turbine engine operates at temperatures that far exceed the melting point of the metals from which they are made. Cooling air from the high pressure compressor must be used to cool the components in the hot sections of the turbine engines. Coolant must be used as effectively as possible in order to increase engine efficiency. The Pressure Sensitive Paint technique (PSP) is used to evaluate the effects of both compound angles and advanced shapes on the film cooling effectiveness. Most current film cooling geometries are orientated streamwise, with mainstream flow, and the addition of the compound angle has shown to both positive and negative effects on cooling effectiveness. These changes are seen based on the type of inlet, cooling geometry, and expansion of the outlet geometry onto the surface.","abstract_has_math":false,"creators":["Bonjonia, Berkley William, 1993-"],"institution":"Baylor University.","degree_name":"M.S.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Wright, Lesley Mae."],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-05","date_published":"2018-05","updated_at":"2026-11-22T16:22:18Z","subjects":["Film cooling."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/10370","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/10370","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2023-08-15","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F10370","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F10370","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wright, Lesley Mae."]},{"key":"dc:creator","label":"Author","values":["Bonjonia, Berkley William, 1993-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-05-30T13:29:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-08-15T13:29:47Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2018"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2018-05"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2023-08-15"]},{"key":"dc:date.issued","label":"Date","values":["2018-05"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2023-08-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-05-30T13:29:47Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Mechanical Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Mechanical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Film cooling."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/10370"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The gas turbine engine operates at temperatures that far exceed the melting point of the metals from which they are made. Cooling air from the high pressure compressor must be used to cool the components in the hot sections of the turbine engines. Coolant must be used as effectively as possible in order to increase engine efficiency. The Pressure Sensitive Paint technique (PSP) is used to evaluate the effects of both compound angles and advanced shapes on the film cooling effectiveness. Most current film cooling geometries are orientated streamwise, with mainstream flow, and the addition of the compound angle has shown to both positive and negative effects on cooling effectiveness. These changes are seen based on the type of inlet, cooling geometry, and expansion of the outlet geometry onto the surface."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Effect of inlet hole geometry on surface film cooling effectiveness from compound angle, shaped holes."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wright, Lesley Mae."],"dc:creator":["Bonjonia, Berkley William, 1993-"],"dc:date.accessioned":["2018-05-30T13:29:47Z"],"dc:date.available":["2023-08-15T13:29:47Z"],"dc:date.copyright":["2018"],"dc:date.created":["2018-05"],"dc:date.embargo":["2023-08-15"],"dc:date.issued":["2018-05"],"dc:date.liftdate":["2023-08-15"],"dc:date.submitted":["May 2018"],"dc:date.updated":["2018-05-30T13:29:47Z"],"dc:description.abstract":["The gas turbine engine operates at temperatures that far exceed the melting point of the metals from which they are made. Cooling air from the high pressure compressor must be used to cool the components in the hot sections of the turbine engines. Coolant must be used as effectively as possible in order to increase engine efficiency. The Pressure Sensitive Paint technique (PSP) is used to evaluate the effects of both compound angles and advanced shapes on the film cooling effectiveness. Most current film cooling geometries are orientated streamwise, with mainstream flow, and the addition of the compound angle has shown to both positive and negative effects on cooling effectiveness. These changes are seen based on the type of inlet, cooling geometry, and expansion of the outlet geometry onto the surface."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/10370"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Film cooling."],"dc:title":["Effect of inlet hole geometry on surface film cooling effectiveness from compound angle, shaped holes."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Mechanical Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.M.E."],"thesis:degree_program":["Mechanical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:22:18Z"}