{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/10682"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/10682","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"High-density intraoperative brain monitoring during cardiac surgery.","abstract":"Functional near-infrared spectroscopy (fNIRS) is a prominent technique that allows assessment of functional brain activity by measuring hemodynamic responses. Most existing functional brain imaging methods are only capable of examining cere-bral oxygenation at the frontal lobes during cardiac surgery; thus, the majority of brain regions remain unmonitored. In an attempt to intraoperatively monitor broader brain regions and detect early oxygen imbalance, high-density fNIRS channels are utilized in this study. A comprehensive test battery of neuropsychological measures is also used to evaluate the subject's cognitive performances pre- and postoperatively and identify cognitive declines following cardiac surgery. The correlation of fNIRS ﬁndings and neurocognitive results is analyzed. Since the results are consistent with previous work, the study indicates the use of fNIRS in detecting potential hypoxia. Future research is necessary to further investigate a larger sample with a systematic approach of physiological interference reduction for fNIRS data.","abstract_html":"Functional near-infrared spectroscopy (fNIRS) is a prominent technique that allows assessment of functional brain activity by measuring hemodynamic responses. Most existing functional brain imaging methods are only capable of examining cere-bral oxygenation at the frontal lobes during cardiac surgery; thus, the majority of brain regions remain unmonitored. In an attempt to intraoperatively monitor broader brain regions and detect early oxygen imbalance, high-density fNIRS channels are utilized in this study. A comprehensive test battery of neuropsychological measures is also used to evaluate the subject&#x27;s cognitive performances pre- and postoperatively and identify cognitive declines following cardiac surgery. The correlation of fNIRS ﬁndings and neurocognitive results is analyzed. Since the results are consistent with previous work, the study indicates the use of fNIRS in detecting potential hypoxia. Future research is necessary to further investigate a larger sample with a systematic approach of physiological interference reduction for fNIRS data.","abstract_has_math":false,"creators":["Nguyen, Ha Hong, 1995-"],"institution":"Baylor University.","degree_name":"M.S.B.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Schubert, Keith Evan."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-05","date_published":"2019-05","updated_at":"2026-11-22T16:19:14Z","subjects":["Functional near-infrared spectroscopy (fNIRS)","POCD.","Oxygen.","Cardiac surgery."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/10682","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/10682","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2021-08-15","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F10682","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F10682","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Schubert, Keith Evan."]},{"key":"dc:creator","label":"Author","values":["Nguyen, Ha Hong, 1995-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-07-29T14:06:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-08-15T14:06:54Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-05"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2021-08-15"]},{"key":"dc:date.issued","label":"Date","values":["2019-05"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2021-08-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-07-29T14:06:54Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.B.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Functional near-infrared spectroscopy (fNIRS)","POCD.","Oxygen.","Cardiac surgery."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/10682"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Functional near-infrared spectroscopy (fNIRS) is a prominent technique that allows assessment of functional brain activity by measuring hemodynamic responses. Most existing functional brain imaging methods are only capable of examining cere-bral oxygenation at the frontal lobes during cardiac surgery; thus, the majority of brain regions remain unmonitored. In an attempt to intraoperatively monitor broader brain regions and detect early oxygen imbalance, high-density fNIRS channels are utilized in this study. A comprehensive test battery of neuropsychological measures is also used to evaluate the subject's cognitive performances pre- and postoperatively and identify cognitive declines following cardiac surgery. The correlation of fNIRS ﬁndings and neurocognitive results is analyzed. Since the results are consistent with previous work, the study indicates the use of fNIRS in detecting potential hypoxia. Future research is necessary to further investigate a larger sample with a systematic approach of physiological interference reduction for fNIRS data."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["High-density intraoperative brain monitoring during cardiac surgery."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Schubert, Keith Evan."],"dc:creator":["Nguyen, Ha Hong, 1995-"],"dc:date.accessioned":["2019-07-29T14:06:54Z"],"dc:date.available":["2021-08-15T14:06:54Z"],"dc:date.copyright":["2019"],"dc:date.created":["2019-05"],"dc:date.embargo":["2021-08-15"],"dc:date.issued":["2019-05"],"dc:date.liftdate":["2021-08-15"],"dc:date.submitted":["May 2019"],"dc:date.updated":["2019-07-29T14:06:54Z"],"dc:description.abstract":["Functional near-infrared spectroscopy (fNIRS) is a prominent technique that allows assessment of functional brain activity by measuring hemodynamic responses. Most existing functional brain imaging methods are only capable of examining cere-bral oxygenation at the frontal lobes during cardiac surgery; thus, the majority of brain regions remain unmonitored. In an attempt to intraoperatively monitor broader brain regions and detect early oxygen imbalance, high-density fNIRS channels are utilized in this study. A comprehensive test battery of neuropsychological measures is also used to evaluate the subject's cognitive performances pre- and postoperatively and identify cognitive declines following cardiac surgery. The correlation of fNIRS ﬁndings and neurocognitive results is analyzed. Since the results are consistent with previous work, the study indicates the use of fNIRS in detecting potential hypoxia. Future research is necessary to further investigate a larger sample with a systematic approach of physiological interference reduction for fNIRS data."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/10682"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Functional near-infrared spectroscopy (fNIRS)","POCD.","Oxygen.","Cardiac surgery."],"dc:title":["High-density intraoperative brain monitoring during cardiac surgery."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.B.M.E."],"thesis:degree_program":["Biomedical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:19:14Z"}