{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/10700"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/10700","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Understanding the effects of high altitude electromagnetic pulse on the US power grid by creating a power grid model and analyzing transformer susceptibility.","abstract":"The purpose of this thesis is to address two topics in understanding the effects of high altitude electromagnetic pulse (HEMP) E3 by determining the latitude and longitude of loadflow buses, and analyzing transformers as the largest risk. This paper will outline the methods used to create a geographic grid model based on the Texas grid. Latitude and longitude values were found for 5000 buses in a grid. Each pair of latitude and longitudes was taken and plotted using Google Earth to verify the locations. With this data a model for the grid was created for a HEMP simulation program. This paper will also cover the analysis of a high voltage (HV) transformer during a HEMP E3 test. This provides an understanding of how harmonics created by HEMP E3 effect the transformer based on loading and the amount of geomagnetically induce current (GIC) into the transformer.","abstract_html":"The purpose of this thesis is to address two topics in understanding the effects of high altitude electromagnetic pulse (HEMP) E3 by determining the latitude and longitude of loadflow buses, and analyzing transformers as the largest risk. This paper will outline the methods used to create a geographic grid model based on the Texas grid. Latitude and longitude values were found for 5000 buses in a grid. Each pair of latitude and longitudes was taken and plotted using Google Earth to verify the locations. With this data a model for the grid was created for a HEMP simulation program. This paper will also cover the analysis of a high voltage (HV) transformer during a HEMP E3 test. This provides an understanding of how harmonics created by HEMP E3 effect the transformer based on loading and the amount of geomagnetically induce current (GIC) into the transformer.","abstract_has_math":false,"creators":["Ridley, David Andrew, 1994-"],"institution":"Baylor University.","degree_name":"M.S.E.C.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Grady, William Mack."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-05","date_published":"2019-05","updated_at":"2026-11-22T16:24:43Z","subjects":["Electrical engineering.","High altitude electromagnetic pulse.","HEMP.","Geomagnetic disturbance.","GMD.","Geomagnetically induced currents.","GIC."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/10700","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/10700","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2021-08-15","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F10700","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F10700","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Grady, William Mack."]},{"key":"dc:creator","label":"Author","values":["Ridley, David Andrew, 1994-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-07-29T14:49:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-08-15T14:49:46Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-05"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2021-08-15"]},{"key":"dc:date.issued","label":"Date","values":["2019-05"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2021-08-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-07-29T14:49:46Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.E.C.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical & Computer Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical engineering.","High altitude electromagnetic pulse.","HEMP.","Geomagnetic disturbance.","GMD.","Geomagnetically induced currents.","GIC."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/10700"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this thesis is to address two topics in understanding the effects of high altitude electromagnetic pulse (HEMP) E3 by determining the latitude and longitude of loadflow buses, and analyzing transformers as the largest risk. This paper will outline the methods used to create a geographic grid model based on the Texas grid. Latitude and longitude values were found for 5000 buses in a grid. Each pair of latitude and longitudes was taken and plotted using Google Earth to verify the locations. With this data a model for the grid was created for a HEMP simulation program. This paper will also cover the analysis of a high voltage (HV) transformer during a HEMP E3 test. This provides an understanding of how harmonics created by HEMP E3 effect the transformer based on loading and the amount of geomagnetically induce current (GIC) into the transformer."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Understanding the effects of high altitude electromagnetic pulse on the US power grid by creating a power grid model and analyzing transformer susceptibility."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Grady, William Mack."],"dc:creator":["Ridley, David Andrew, 1994-"],"dc:date.accessioned":["2019-07-29T14:49:46Z"],"dc:date.available":["2021-08-15T14:49:46Z"],"dc:date.copyright":["2019"],"dc:date.created":["2019-05"],"dc:date.embargo":["2021-08-15"],"dc:date.issued":["2019-05"],"dc:date.liftdate":["2021-08-15"],"dc:date.submitted":["May 2019"],"dc:date.updated":["2019-07-29T14:49:46Z"],"dc:description.abstract":["The purpose of this thesis is to address two topics in understanding the effects of high altitude electromagnetic pulse (HEMP) E3 by determining the latitude and longitude of loadflow buses, and analyzing transformers as the largest risk. This paper will outline the methods used to create a geographic grid model based on the Texas grid. Latitude and longitude values were found for 5000 buses in a grid. Each pair of latitude and longitudes was taken and plotted using Google Earth to verify the locations. With this data a model for the grid was created for a HEMP simulation program. This paper will also cover the analysis of a high voltage (HV) transformer during a HEMP E3 test. This provides an understanding of how harmonics created by HEMP E3 effect the transformer based on loading and the amount of geomagnetically induce current (GIC) into the transformer."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/10700"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Electrical engineering.","High altitude electromagnetic pulse.","HEMP.","Geomagnetic disturbance.","GMD.","Geomagnetically induced currents.","GIC."],"dc:title":["Understanding the effects of high altitude electromagnetic pulse on the US power grid by creating a power grid model and analyzing transformer susceptibility."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.E.C.E."],"thesis:degree_program":["Electrical & Computer Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:24:43Z"}