{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/10800"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/10800","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"An electromagnetic sensor and method for extraction of transient vapor fraction in dynamic systems.","abstract":"The capture of transient steam quality provides valuable insight into the operational conditions needed for process control and design of saturated steam systems. Acquisition of accurate fluid phase or composition before the system reaches steady-state operation poses technical challenges preventing the use of most existing commercial and experimental methods. An electromagnetic sensing method in the microwave frequency band enables this capture of compositional data at over 200 samples per second. The planar microwave sensing element allows for the in-situ measurement of a two species fluid to be taken, without the usual requirement of laminar flow found in many density-based approaches. Harsh environmental conditions presented in typical saturated steam processes dictated special design considerations to enable survivability of the sensor. Effective medium models for both pure and polluted saturated steam were implemented to compensate for contamination of the working fluid to provide estimated bounds for a mass fraction of the liquid to vapor content. The addition of pressure and temperature data enables an estimate of enthalpy made for saturated fluid cases and applications.","abstract_html":"The capture of transient steam quality provides valuable insight into the operational conditions needed for process control and design of saturated steam systems. Acquisition of accurate fluid phase or composition before the system reaches steady-state operation poses technical challenges preventing the use of most existing commercial and experimental methods. An electromagnetic sensing method in the microwave frequency band enables this capture of compositional data at over 200 samples per second. The planar microwave sensing element allows for the in-situ measurement of a two species fluid to be taken, without the usual requirement of laminar flow found in many density-based approaches. Harsh environmental conditions presented in typical saturated steam processes dictated special design considerations to enable survivability of the sensor. Effective medium models for both pure and polluted saturated steam were implemented to compensate for contamination of the working fluid to provide estimated bounds for a mass fraction of the liquid to vapor content. The addition of pressure and temperature data enables an estimate of enthalpy made for saturated fluid cases and applications.","abstract_has_math":false,"creators":["Faulkner, Christopher David, 1990-"],"institution":"Baylor University.","degree_name":"Ph.D.","degree_level":"Doctoral","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Jean, B. Randall."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-12","date_published":"2019-12","updated_at":"2026-11-22T16:22:25Z","subjects":["Steam quality.","Transient.","Microwave.","Measurement.","RF sensing.","Material sensing."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/10800","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/10800","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2025-05-15","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F10800","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F10800","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jean, B. Randall."]},{"key":"dc:creator","label":"Author","values":["Faulkner, Christopher David, 1990-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-02-19T16:48:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-05-15T16:48:24Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-12"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2025-05-15"]},{"key":"dc:date.issued","label":"Date","values":["2019-12"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2025-05-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2020-02-19T16:48:24Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical & Computer Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Steam quality.","Transient.","Microwave.","Measurement.","RF sensing.","Material sensing."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/10800"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The capture of transient steam quality provides valuable insight into the operational conditions needed for process control and design of saturated steam systems. Acquisition of accurate fluid phase or composition before the system reaches steady-state operation poses technical challenges preventing the use of most existing commercial and experimental methods. An electromagnetic sensing method in the microwave frequency band enables this capture of compositional data at over 200 samples per second. The planar microwave sensing element allows for the in-situ measurement of a two species fluid to be taken, without the usual requirement of laminar flow found in many density-based approaches. Harsh environmental conditions presented in typical saturated steam processes dictated special design considerations to enable survivability of the sensor. Effective medium models for both pure and polluted saturated steam were implemented to compensate for contamination of the working fluid to provide estimated bounds for a mass fraction of the liquid to vapor content. The addition of pressure and temperature data enables an estimate of enthalpy made for saturated fluid cases and applications."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["An electromagnetic sensor and method for extraction of transient vapor fraction in dynamic systems."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jean, B. Randall."],"dc:creator":["Faulkner, Christopher David, 1990-"],"dc:date.accessioned":["2020-02-19T16:48:24Z"],"dc:date.available":["2025-05-15T16:48:24Z"],"dc:date.copyright":["2019"],"dc:date.created":["2019-12"],"dc:date.embargo":["2025-05-15"],"dc:date.issued":["2019-12"],"dc:date.liftdate":["2025-05-15"],"dc:date.submitted":["December 2019"],"dc:date.updated":["2020-02-19T16:48:24Z"],"dc:description.abstract":["The capture of transient steam quality provides valuable insight into the operational conditions needed for process control and design of saturated steam systems. Acquisition of accurate fluid phase or composition before the system reaches steady-state operation poses technical challenges preventing the use of most existing commercial and experimental methods. An electromagnetic sensing method in the microwave frequency band enables this capture of compositional data at over 200 samples per second. The planar microwave sensing element allows for the in-situ measurement of a two species fluid to be taken, without the usual requirement of laminar flow found in many density-based approaches. Harsh environmental conditions presented in typical saturated steam processes dictated special design considerations to enable survivability of the sensor. Effective medium models for both pure and polluted saturated steam were implemented to compensate for contamination of the working fluid to provide estimated bounds for a mass fraction of the liquid to vapor content. The addition of pressure and temperature data enables an estimate of enthalpy made for saturated fluid cases and applications."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/10800"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Steam quality.","Transient.","Microwave.","Measurement.","RF sensing.","Material sensing."],"dc:title":["An electromagnetic sensor and method for extraction of transient vapor fraction in dynamic systems."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Ph.D."],"thesis:degree_program":["Electrical & Computer Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:22:25Z"}