{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/11210"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/11210","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Assessing precision and application of marker placement device to enhance motion capture studies.","abstract":"Motion capture has become an important clinical tool used in applications of therapy and treatment plans as well as surgical evaluations. However, due to factors such as human error, having multiple examiners, and using multiple days, there is an inherent presence of error within clinical motion capture due to marker replacement. The objective of this study was to develop and evaluate a device that increases the precision of repeatedly placing motion capture markers on a subject for between-day and between-examiner situations. Each mechanical component of the device, as well as body positioning and marker placement repeatability, was evaluated for differences that compounded throughout the process. Kinematic trials were executed to indicate the significance of the device in application. The results showed that the device performed superiorly to human marking of all levels, producing maximum difference measurements of <8.08 mm and minimal measurements resulting in significant kinematic change.","abstract_html":"Motion capture has become an important clinical tool used in applications of therapy and treatment plans as well as surgical evaluations. However, due to factors such as human error, having multiple examiners, and using multiple days, there is an inherent presence of error within clinical motion capture due to marker replacement. The objective of this study was to develop and evaluate a device that increases the precision of repeatedly placing motion capture markers on a subject for between-day and between-examiner situations. Each mechanical component of the device, as well as body positioning and marker placement repeatability, was evaluated for differences that compounded throughout the process. Kinematic trials were executed to indicate the significance of the device in application. The results showed that the device performed superiorly to human marking of all levels, producing maximum difference measurements of &lt;8.08 mm and minimal measurements resulting in significant kinematic change.","abstract_has_math":false,"creators":["Whiddon, Forrest J., 1994-"],"institution":"Baylor University.","degree_name":"M.S.B.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Rylander, Jonathan."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-12","date_published":"2020-12","updated_at":"2026-11-22T16:22:25Z","subjects":["Motion capture.","Gait analysis.","Gait.","Mocap.","Marker.","Marker placement.","Repeatability."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-3579-8572"],"render_values":[{"text":"0000-0002-3579-8572","href":"https://orcid.org/0000-0002-3579-8572","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/2104/11210","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/11210","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2023-05-15","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F11210","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F11210","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rylander, Jonathan."]},{"key":"dc:creator","label":"Author","values":["Whiddon, Forrest J., 1994-"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-3579-8572"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-01-28T15:38:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-05-15T15:38:29Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2020-12"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2023-05-15"]},{"key":"dc:date.issued","label":"Date","values":["2020-12"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2023-05-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2020"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-01-28T15:38:30Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Mechanical Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.B.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Motion capture.","Gait analysis.","Gait.","Mocap.","Marker.","Marker placement.","Repeatability."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/11210"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Motion capture has become an important clinical tool used in applications of therapy and treatment plans as well as surgical evaluations. However, due to factors such as human error, having multiple examiners, and using multiple days, there is an inherent presence of error within clinical motion capture due to marker replacement. The objective of this study was to develop and evaluate a device that increases the precision of repeatedly placing motion capture markers on a subject for between-day and between-examiner situations. Each mechanical component of the device, as well as body positioning and marker placement repeatability, was evaluated for differences that compounded throughout the process. Kinematic trials were executed to indicate the significance of the device in application. The results showed that the device performed superiorly to human marking of all levels, producing maximum difference measurements of <8.08 mm and minimal measurements resulting in significant kinematic change."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Assessing precision and application of marker placement device to enhance motion capture studies."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rylander, Jonathan."],"dc:creator":["Whiddon, Forrest J., 1994-"],"dc:date.accessioned":["2021-01-28T15:38:29Z"],"dc:date.available":["2023-05-15T15:38:29Z"],"dc:date.copyright":["2020"],"dc:date.created":["2020-12"],"dc:date.embargo":["2023-05-15"],"dc:date.issued":["2020-12"],"dc:date.liftdate":["2023-05-15"],"dc:date.submitted":["December 2020"],"dc:date.updated":["2021-01-28T15:38:30Z"],"dc:description.abstract":["Motion capture has become an important clinical tool used in applications of therapy and treatment plans as well as surgical evaluations. However, due to factors such as human error, having multiple examiners, and using multiple days, there is an inherent presence of error within clinical motion capture due to marker replacement. The objective of this study was to develop and evaluate a device that increases the precision of repeatedly placing motion capture markers on a subject for between-day and between-examiner situations. Each mechanical component of the device, as well as body positioning and marker placement repeatability, was evaluated for differences that compounded throughout the process. Kinematic trials were executed to indicate the significance of the device in application. The results showed that the device performed superiorly to human marking of all levels, producing maximum difference measurements of <8.08 mm and minimal measurements resulting in significant kinematic change."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/11210"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Motion capture.","Gait analysis.","Gait.","Mocap.","Marker.","Marker placement.","Repeatability."],"dc:title":["Assessing precision and application of marker placement device to enhance motion capture studies."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0000-0002-3579-8572"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Mechanical Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.B.M.E."],"thesis:degree_program":["Biomedical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:22:25Z"}