{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/11513"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/11513","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Evaluating a commercially available, immersive virtual reality system for measuring common lower body rehabilitation motions.","abstract":"Lower body rehabilitation has been marked by qualitative assessments and observations. Quantitative measuring devices often present a financial burden that many clinics cannot overcome. Virtual Reality (VR) systems offer less of an economic undertaking but have not been extensively evaluated. In this study, a first-person, immersive VR system with limb tracking peripheral devices (Valve Index with Vive Trackers) were used alongside a Gold-Standard, 3D marker-based motion capture system (Vicon Vantage) to evaluate how well the VR system could measure foot and lower back position and movement during walking, balance, and a Four Square Step Test. Eighteen healthy subjects were recruited and asked to perform these clinical assessments while VR trackers and Motion Capture markers collected their feet and center of gravity position. While the VR system could track motions consistent with the Motion Capture, discrepancies persist due to the tracker's bulkiness, position on the foot, and limitations with tracking small movements.","abstract_html":"Lower body rehabilitation has been marked by qualitative assessments and observations. Quantitative measuring devices often present a financial burden that many clinics cannot overcome. Virtual Reality (VR) systems offer less of an economic undertaking but have not been extensively evaluated. In this study, a first-person, immersive VR system with limb tracking peripheral devices (Valve Index with Vive Trackers) were used alongside a Gold-Standard, 3D marker-based motion capture system (Vicon Vantage) to evaluate how well the VR system could measure foot and lower back position and movement during walking, balance, and a Four Square Step Test. Eighteen healthy subjects were recruited and asked to perform these clinical assessments while VR trackers and Motion Capture markers collected their feet and center of gravity position. While the VR system could track motions consistent with the Motion Capture, discrepancies persist due to the tracker&#x27;s bulkiness, position on the foot, and limitations with tracking small movements.","abstract_has_math":false,"creators":["Leitch, Madison Paige, 1997-"],"institution":"Baylor University.","degree_name":"M.S.B.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Rylander, Jonathan."],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-05","date_published":"2021-05","updated_at":"2026-11-22T16:19:41Z","subjects":["Virtual reality (VR)","Motion capture.","Stepping parameters.","Lower body rehabilitation.","Rehabilitation.","Biomechanics.","Balance testing.","Four square step test.","Stair stepping.","Gait analysis.","Vicon.","Valve Index.","HTC VIVE.","Virtual reality (VR) trackers."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-3688-4958"],"render_values":[{"text":"0000-0002-3688-4958","href":"https://orcid.org/0000-0002-3688-4958","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/2104/11513","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/11513","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2023-08-15","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F11513","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F11513","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rylander, Jonathan."]},{"key":"dc:creator","label":"Author","values":["Leitch, Madison Paige, 1997-"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-3688-4958"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-07-14T14:11:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-08-15T14:11:22Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-05"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2023-08-15"]},{"key":"dc:date.issued","label":"Date","values":["2021-05"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2023-08-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-07-14T14:11:23Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Mechanical Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.B.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Virtual reality (VR)","Motion capture.","Stepping parameters.","Lower body rehabilitation.","Rehabilitation.","Biomechanics.","Balance testing.","Four square step test.","Stair stepping.","Gait analysis.","Vicon.","Valve Index.","HTC VIVE.","Virtual reality (VR) trackers."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/11513"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lower body rehabilitation has been marked by qualitative assessments and observations. Quantitative measuring devices often present a financial burden that many clinics cannot overcome. Virtual Reality (VR) systems offer less of an economic undertaking but have not been extensively evaluated. In this study, a first-person, immersive VR system with limb tracking peripheral devices (Valve Index with Vive Trackers) were used alongside a Gold-Standard, 3D marker-based motion capture system (Vicon Vantage) to evaluate how well the VR system could measure foot and lower back position and movement during walking, balance, and a Four Square Step Test. Eighteen healthy subjects were recruited and asked to perform these clinical assessments while VR trackers and Motion Capture markers collected their feet and center of gravity position. While the VR system could track motions consistent with the Motion Capture, discrepancies persist due to the tracker's bulkiness, position on the foot, and limitations with tracking small movements."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Evaluating a commercially available, immersive virtual reality system for measuring common lower body rehabilitation motions."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rylander, Jonathan."],"dc:creator":["Leitch, Madison Paige, 1997-"],"dc:date.accessioned":["2021-07-14T14:11:22Z"],"dc:date.available":["2023-08-15T14:11:22Z"],"dc:date.copyright":["2021"],"dc:date.created":["2021-05"],"dc:date.embargo":["2023-08-15"],"dc:date.issued":["2021-05"],"dc:date.liftdate":["2023-08-15"],"dc:date.submitted":["May 2021"],"dc:date.updated":["2021-07-14T14:11:23Z"],"dc:description.abstract":["Lower body rehabilitation has been marked by qualitative assessments and observations. Quantitative measuring devices often present a financial burden that many clinics cannot overcome. Virtual Reality (VR) systems offer less of an economic undertaking but have not been extensively evaluated. In this study, a first-person, immersive VR system with limb tracking peripheral devices (Valve Index with Vive Trackers) were used alongside a Gold-Standard, 3D marker-based motion capture system (Vicon Vantage) to evaluate how well the VR system could measure foot and lower back position and movement during walking, balance, and a Four Square Step Test. Eighteen healthy subjects were recruited and asked to perform these clinical assessments while VR trackers and Motion Capture markers collected their feet and center of gravity position. While the VR system could track motions consistent with the Motion Capture, discrepancies persist due to the tracker's bulkiness, position on the foot, and limitations with tracking small movements."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/11513"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Virtual reality (VR)","Motion capture.","Stepping parameters.","Lower body rehabilitation.","Rehabilitation.","Biomechanics.","Balance testing.","Four square step test.","Stair stepping.","Gait analysis.","Vicon.","Valve Index.","HTC VIVE.","Virtual reality (VR) trackers."],"dc:title":["Evaluating a commercially available, immersive virtual reality system for measuring common lower body rehabilitation motions."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0000-0002-3688-4958"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Mechanical Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.B.M.E."],"thesis:degree_program":["Biomedical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:19:41Z"}