{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/11517"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/11517","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Improving the quality of proton CT scan images by utilizing straggling power.","abstract":"Proton therapy has grown in interest within the medical community for its promise in cancer treatment. Proton CT (pCT) scans are an essential part of this process to map treatment areas, but a common problem is the lack of precision along the artifact boundaries within the image. It was hypothesized that combining two forms of collected data, stopping power and scattering power, may result in a sharper image. Initial testing harnessed typical filtering techniques to improve the combined image, but did not result in sharpened boundaries. Further testing harnessed knowledge of the data itself, such as respective contained information, and medical imaging techniques to improve the combined image. Qualitative analysis by inspection was verified quantitatively by calculating the FWHM. These results showed an average improvement of 0.3967 mm for the combined image compared to the stopping power image.","abstract_html":"Proton therapy has grown in interest within the medical community for its promise in cancer treatment. Proton CT (pCT) scans are an essential part of this process to map treatment areas, but a common problem is the lack of precision along the artifact boundaries within the image. It was hypothesized that combining two forms of collected data, stopping power and scattering power, may result in a sharper image. Initial testing harnessed typical filtering techniques to improve the combined image, but did not result in sharpened boundaries. Further testing harnessed knowledge of the data itself, such as respective contained information, and medical imaging techniques to improve the combined image. Qualitative analysis by inspection was verified quantitatively by calculating the FWHM. These results showed an average improvement of 0.3967 mm for the combined image compared to the stopping power image.","abstract_has_math":false,"creators":["Reeser, Jordan Lee, 1996-"],"institution":"Baylor University.","degree_name":"M.S.E.C.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Schubert, Keith Evan."],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-05","date_published":"2021-05","updated_at":"2026-11-22T16:22:25Z","subjects":["Proton therapy.","Proton CT.","PCT.","Straggling power.","Medical imaging."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-6322-0401"],"render_values":[{"text":"0000-0002-6322-0401","href":"https://orcid.org/0000-0002-6322-0401","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/2104/11517","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/11517","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F11517","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F11517","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Schubert, Keith Evan."]},{"key":"dc:creator","label":"Author","values":["Reeser, Jordan Lee, 1996-"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000-0002-6322-0401"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-07-14T14:11:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-07-14T14:11:32Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-05"]},{"key":"dc:date.issued","label":"Date","values":["2021-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-07-14T14:11:33Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.E.C.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical & Computer Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Proton therapy.","Proton CT.","PCT.","Straggling power.","Medical imaging."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/11517"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Proton therapy has grown in interest within the medical community for its promise in cancer treatment. Proton CT (pCT) scans are an essential part of this process to map treatment areas, but a common problem is the lack of precision along the artifact boundaries within the image. It was hypothesized that combining two forms of collected data, stopping power and scattering power, may result in a sharper image. Initial testing harnessed typical filtering techniques to improve the combined image, but did not result in sharpened boundaries. Further testing harnessed knowledge of the data itself, such as respective contained information, and medical imaging techniques to improve the combined image. Qualitative analysis by inspection was verified quantitatively by calculating the FWHM. These results showed an average improvement of 0.3967 mm for the combined image compared to the stopping power image."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Improving the quality of proton CT scan images by utilizing straggling power."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Schubert, Keith Evan."],"dc:creator":["Reeser, Jordan Lee, 1996-"],"dc:date.accessioned":["2021-07-14T14:11:32Z"],"dc:date.available":["2021-07-14T14:11:32Z"],"dc:date.copyright":["2021"],"dc:date.created":["2021-05"],"dc:date.issued":["2021-05"],"dc:date.submitted":["May 2021"],"dc:date.updated":["2021-07-14T14:11:33Z"],"dc:description.abstract":["Proton therapy has grown in interest within the medical community for its promise in cancer treatment. Proton CT (pCT) scans are an essential part of this process to map treatment areas, but a common problem is the lack of precision along the artifact boundaries within the image. It was hypothesized that combining two forms of collected data, stopping power and scattering power, may result in a sharper image. Initial testing harnessed typical filtering techniques to improve the combined image, but did not result in sharpened boundaries. Further testing harnessed knowledge of the data itself, such as respective contained information, and medical imaging techniques to improve the combined image. Qualitative analysis by inspection was verified quantitatively by calculating the FWHM. These results showed an average improvement of 0.3967 mm for the combined image compared to the stopping power image."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/11517"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Proton therapy.","Proton CT.","PCT.","Straggling power.","Medical imaging."],"dc:title":["Improving the quality of proton CT scan images by utilizing straggling power."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0000-0002-6322-0401"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.E.C.E."],"thesis:degree_program":["Electrical & Computer Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:22:25Z"}