{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/11732"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/11732","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Intra-rater reliability of rehabilitative ultrasound imaging of the erector spinae and gluteus medius muscles.","abstract":"Rehabilitative ultrasound imaging (RUSI) is an evolving tool which allows non-invasive quantification of muscle function. Currently, RUSI is used primarily in abdominal and lumbar multifidus muscles, and there is a need to expand its use to other clinically relevant muscle groups. The purpose of this study was to examine intra-rater reliability of RUSI measurements of erector spinae (ES) and gluteus medius (GM) muscle thickness at rest and at submaximal contraction in healthy participants. Methods: ES and GM muscles of 30 participants were imaged at rest and submaximal contraction. Intra-rater reliability estimates using a single and average of three measurements were also compared. Results: ICCs for both ES and GM muscle thickness ranged between .89 to .93 for single measures and from .94 - .97 for average measures. Conclusion: This study confirms a high intra-rater reliability of ultrasound measurements of ES and GM muscle thickness when an average of three measures are used.","abstract_html":"Rehabilitative ultrasound imaging (RUSI) is an evolving tool which allows non-invasive quantification of muscle function. Currently, RUSI is used primarily in abdominal and lumbar multifidus muscles, and there is a need to expand its use to other clinically relevant muscle groups. The purpose of this study was to examine intra-rater reliability of RUSI measurements of erector spinae (ES) and gluteus medius (GM) muscle thickness at rest and at submaximal contraction in healthy participants. Methods: ES and GM muscles of 30 participants were imaged at rest and submaximal contraction. Intra-rater reliability estimates using a single and average of three measurements were also compared. Results: ICCs for both ES and GM muscle thickness ranged between .89 to .93 for single measures and from .94 - .97 for average measures. Conclusion: This study confirms a high intra-rater reliability of ultrasound measurements of ES and GM muscle thickness when an average of three measures are used.","abstract_has_math":false,"creators":["Pokhrel, Swikriti, 1995-"],"institution":"Baylor University.","degree_name":"M.S.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Health, Human Performance & Recreation.","school":null,"contributors":[],"advisors":["Koppenhaver, Shane."],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-12","date_published":"2021-12","updated_at":"2026-11-22T16:24:43Z","subjects":["Rehabilitative ultrasound imaging.","Gluteus medius.","Erector spinae."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/11732","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/11732","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F11732","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F11732","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Koppenhaver, Shane."]},{"key":"dc:creator","label":"Author","values":["Pokhrel, Swikriti, 1995-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-01-28T14:50:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-01-28T14:50:26Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2021"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-12"]},{"key":"dc:date.issued","label":"Date","values":["2021-12"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2021"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2022-01-28T14:50:28Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["Robbins College of Health & Human Services."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Health, Human Performance & Recreation."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Exercise Physiology."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Rehabilitative ultrasound imaging.","Gluteus medius.","Erector spinae."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/11732"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Rehabilitative ultrasound imaging (RUSI) is an evolving tool which allows non-invasive quantification of muscle function. Currently, RUSI is used primarily in abdominal and lumbar multifidus muscles, and there is a need to expand its use to other clinically relevant muscle groups. The purpose of this study was to examine intra-rater reliability of RUSI measurements of erector spinae (ES) and gluteus medius (GM) muscle thickness at rest and at submaximal contraction in healthy participants. Methods: ES and GM muscles of 30 participants were imaged at rest and submaximal contraction. Intra-rater reliability estimates using a single and average of three measurements were also compared. Results: ICCs for both ES and GM muscle thickness ranged between .89 to .93 for single measures and from .94 - .97 for average measures. Conclusion: This study confirms a high intra-rater reliability of ultrasound measurements of ES and GM muscle thickness when an average of three measures are used."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Intra-rater reliability of rehabilitative ultrasound imaging of the erector spinae and gluteus medius muscles."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Koppenhaver, Shane."],"dc:creator":["Pokhrel, Swikriti, 1995-"],"dc:date.accessioned":["2022-01-28T14:50:26Z"],"dc:date.available":["2022-01-28T14:50:26Z"],"dc:date.copyright":["2021"],"dc:date.created":["2021-12"],"dc:date.issued":["2021-12"],"dc:date.submitted":["December 2021"],"dc:date.updated":["2022-01-28T14:50:28Z"],"dc:description.abstract":["Rehabilitative ultrasound imaging (RUSI) is an evolving tool which allows non-invasive quantification of muscle function. Currently, RUSI is used primarily in abdominal and lumbar multifidus muscles, and there is a need to expand its use to other clinically relevant muscle groups. The purpose of this study was to examine intra-rater reliability of RUSI measurements of erector spinae (ES) and gluteus medius (GM) muscle thickness at rest and at submaximal contraction in healthy participants. Methods: ES and GM muscles of 30 participants were imaged at rest and submaximal contraction. Intra-rater reliability estimates using a single and average of three measurements were also compared. Results: ICCs for both ES and GM muscle thickness ranged between .89 to .93 for single measures and from .94 - .97 for average measures. Conclusion: This study confirms a high intra-rater reliability of ultrasound measurements of ES and GM muscle thickness when an average of three measures are used."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/11732"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Rehabilitative ultrasound imaging.","Gluteus medius.","Erector spinae."],"dc:title":["Intra-rater reliability of rehabilitative ultrasound imaging of the erector spinae and gluteus medius muscles."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["Robbins College of Health & Human Services."],"thesis:degree_department":["Dept. of Health, Human Performance & Recreation."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:degree_program":["Exercise Physiology."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:24:43Z"}