{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/12459"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/12459","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Characterization of sub-surface wrinkles within a laminated composite using a novel phased array ultrasonic scanning technique incorporating a portable nozzle and robotic arm.","abstract":"Due to their superior strength to weight ratio as compared to metals, the use of laminated composites is growing in the aerospace, automotive and energy sectors. This increased performance is severely compromised by the presence of out-of-plane wrinkles, a manufacturing defect that occurs in thick complex curvature composite stacks. This thesis presents an ultrasound scanning technique utilizing a novel phased array approach to detect out-of-plane wrinkles and, unlike previous literature results, quantify wrinkle dimensions. Multiple nozzle designs are provided for phased array probes to improve portability and scanning setup. A robotic system is presented that incorporates the novel scanning technique, which allows inspection of parts with non-planar geometries. The measured quantities are validated using 𝜇-CT scans, and results are provided that show average relative errors of 8.33%, 22.79% and 9.72% for, respectively, wrinkle height, width, and intensity corresponding to an average absolute error of, respectively, 0.057mm, 1.59mm and 4.7 × 10−3 .","abstract_html":"Due to their superior strength to weight ratio as compared to metals, the use of laminated composites is growing in the aerospace, automotive and energy sectors. This increased performance is severely compromised by the presence of out-of-plane wrinkles, a manufacturing defect that occurs in thick complex curvature composite stacks. This thesis presents an ultrasound scanning technique utilizing a novel phased array approach to detect out-of-plane wrinkles and, unlike previous literature results, quantify wrinkle dimensions. Multiple nozzle designs are provided for phased array probes to improve portability and scanning setup. A robotic system is presented that incorporates the novel scanning technique, which allows inspection of parts with non-planar geometries. The measured quantities are validated using 𝜇-CT scans, and results are provided that show average relative errors of 8.33%, 22.79% and 9.72% for, respectively, wrinkle height, width, and intensity corresponding to an average absolute error of, respectively, 0.057mm, 1.59mm and 4.7 × 10−3 .","abstract_has_math":false,"creators":["Khan, Irrtisum, 1993-"],"institution":"Baylor University.","degree_name":"M.S.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Jack, David Abram, 1977-"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-05","date_published":"2023-05","updated_at":"2026-11-22T16:19:14Z","subjects":["Non-destructive testing (NDT)","Robotic arm.","Ultrasound.","Phased array.","Wrinkle.","Carbon fiber."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/12459","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/12459","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":"embargoed","embargo_until":"2025-08-15","access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F12459","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F12459","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jack, David Abram, 1977-"]},{"key":"dc:creator","label":"Author","values":["Khan, Irrtisum, 1993-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-11-07T14:19:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-15T14:19:51Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2023"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-05"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2025-08-15"]},{"key":"dc:date.issued","label":"Date","values":["2023-05"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2025-08-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-11-07T14:19:52Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Mechanical Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Mechanical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Non-destructive testing (NDT)","Robotic arm.","Ultrasound.","Phased array.","Wrinkle.","Carbon fiber."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/12459"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Due to their superior strength to weight ratio as compared to metals, the use of laminated composites is growing in the aerospace, automotive and energy sectors. This increased performance is severely compromised by the presence of out-of-plane wrinkles, a manufacturing defect that occurs in thick complex curvature composite stacks. This thesis presents an ultrasound scanning technique utilizing a novel phased array approach to detect out-of-plane wrinkles and, unlike previous literature results, quantify wrinkle dimensions. Multiple nozzle designs are provided for phased array probes to improve portability and scanning setup. A robotic system is presented that incorporates the novel scanning technique, which allows inspection of parts with non-planar geometries. The measured quantities are validated using 𝜇-CT scans, and results are provided that show average relative errors of 8.33%, 22.79% and 9.72% for, respectively, wrinkle height, width, and intensity corresponding to an average absolute error of, respectively, 0.057mm, 1.59mm and 4.7 × 10−3 ."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization of sub-surface wrinkles within a laminated composite using a novel phased array ultrasonic scanning technique incorporating a portable nozzle and robotic arm."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jack, David Abram, 1977-"],"dc:creator":["Khan, Irrtisum, 1993-"],"dc:date.accessioned":["2023-11-07T14:19:51Z"],"dc:date.available":["2025-08-15T14:19:51Z"],"dc:date.copyright":["2023"],"dc:date.created":["2023-05"],"dc:date.embargo":["2025-08-15"],"dc:date.issued":["2023-05"],"dc:date.liftdate":["2025-08-15"],"dc:date.submitted":["May 2023"],"dc:date.updated":["2023-11-07T14:19:52Z"],"dc:description.abstract":["Due to their superior strength to weight ratio as compared to metals, the use of laminated composites is growing in the aerospace, automotive and energy sectors. This increased performance is severely compromised by the presence of out-of-plane wrinkles, a manufacturing defect that occurs in thick complex curvature composite stacks. This thesis presents an ultrasound scanning technique utilizing a novel phased array approach to detect out-of-plane wrinkles and, unlike previous literature results, quantify wrinkle dimensions. Multiple nozzle designs are provided for phased array probes to improve portability and scanning setup. A robotic system is presented that incorporates the novel scanning technique, which allows inspection of parts with non-planar geometries. The measured quantities are validated using 𝜇-CT scans, and results are provided that show average relative errors of 8.33%, 22.79% and 9.72% for, respectively, wrinkle height, width, and intensity corresponding to an average absolute error of, respectively, 0.057mm, 1.59mm and 4.7 × 10−3 ."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/12459"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Non-destructive testing (NDT)","Robotic arm.","Ultrasound.","Phased array.","Wrinkle.","Carbon fiber."],"dc:title":["Characterization of sub-surface wrinkles within a laminated composite using a novel phased array ultrasonic scanning technique incorporating a portable nozzle and robotic arm."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Mechanical Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.M.E."],"thesis:degree_program":["Mechanical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:19:14Z"}