{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/13063"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/13063","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Advancement of non-ionizing Imaging techniques for clinical applications : a compact diffuse optical tomography system and the ultrasound localization of subwavelength nitinol wires in anatomical manikin vasculature.","abstract":"Minimally invasive surgical techniques have significantly improved outcomes for neurovascular and coronary pathologies. However, there remain some operational safety risks including the dosage of ionizing radiation due to fluoroscopic imaging, as well as complications due to inadvertent vessel puncture. Nitinol is a well-established biocompatible shape-memory alloy that may enable more degrees of freedom (DoF) in endovascular techniques. Additionally, diffuse optical tomography (DOT) and ultrasound are promising non-ionizing modalities that may be incorporated to validate instrument localization and thereby reduce radiation dose. I propose a compact DOT system assembled with affordable and accessible components capable of reconstructing the cross-sectional image of an off-center object within an opaque gelatin phantom within 10 % error in cross-sectional area from its specified area in CAD software. Additionally, I will describe a methodology of localizing subwavelength nitinol wires via ultrasound in the synthetic venous pathways of the right forearm of an anatomical manikin.","abstract_html":"Minimally invasive surgical techniques have significantly improved outcomes for neurovascular and coronary pathologies. However, there remain some operational safety risks including the dosage of ionizing radiation due to fluoroscopic imaging, as well as complications due to inadvertent vessel puncture. Nitinol is a well-established biocompatible shape-memory alloy that may enable more degrees of freedom (DoF) in endovascular techniques. Additionally, diffuse optical tomography (DOT) and ultrasound are promising non-ionizing modalities that may be incorporated to validate instrument localization and thereby reduce radiation dose. I propose a compact DOT system assembled with affordable and accessible components capable of reconstructing the cross-sectional image of an off-center object within an opaque gelatin phantom within 10 % error in cross-sectional area from its specified area in CAD software. Additionally, I will describe a methodology of localizing subwavelength nitinol wires via ultrasound in the synthetic venous pathways of the right forearm of an anatomical manikin.","abstract_has_math":false,"creators":["Balzora, Stephen E., 1997-"],"institution":"Baylor University.","degree_name":"M.S.B.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Schubert, Keith Evan."],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-08","date_published":"2024-08","updated_at":"2026-11-22T16:22:25Z","subjects":["Endovascular techniques.","Nitinol wires.","Ultrasound.","Non-ionizing imaging.","Diffuse optical tomography."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0009-1817-5961"],"render_values":[{"text":"0009-0009-1817-5961","href":"https://orcid.org/0009-0009-1817-5961","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/2104/13063","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/13063","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F13063","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F13063","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Schubert, Keith Evan."]},{"key":"dc:creator","label":"Author","values":["Balzora, Stephen E., 1997-"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0009-0009-1817-5961"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-12-19T15:57:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-12-19T15:57:11Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2024"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-08"]},{"key":"dc:date.issued","label":"Date","values":["2024-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-12-19T15:57:11Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.B.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Endovascular techniques.","Nitinol wires.","Ultrasound.","Non-ionizing imaging.","Diffuse optical tomography."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/13063"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Minimally invasive surgical techniques have significantly improved outcomes for neurovascular and coronary pathologies. However, there remain some operational safety risks including the dosage of ionizing radiation due to fluoroscopic imaging, as well as complications due to inadvertent vessel puncture. Nitinol is a well-established biocompatible shape-memory alloy that may enable more degrees of freedom (DoF) in endovascular techniques. Additionally, diffuse optical tomography (DOT) and ultrasound are promising non-ionizing modalities that may be incorporated to validate instrument localization and thereby reduce radiation dose. I propose a compact DOT system assembled with affordable and accessible components capable of reconstructing the cross-sectional image of an off-center object within an opaque gelatin phantom within 10 % error in cross-sectional area from its specified area in CAD software. Additionally, I will describe a methodology of localizing subwavelength nitinol wires via ultrasound in the synthetic venous pathways of the right forearm of an anatomical manikin."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Advancement of non-ionizing Imaging techniques for clinical applications : a compact diffuse optical tomography system and the ultrasound localization of subwavelength nitinol wires in anatomical manikin vasculature."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Schubert, Keith Evan."],"dc:creator":["Balzora, Stephen E., 1997-"],"dc:date.accessioned":["2024-12-19T15:57:11Z"],"dc:date.available":["2024-12-19T15:57:11Z"],"dc:date.copyright":["2024"],"dc:date.created":["2024-08"],"dc:date.issued":["2024-08"],"dc:date.submitted":["August 2024"],"dc:date.updated":["2024-12-19T15:57:11Z"],"dc:description.abstract":["Minimally invasive surgical techniques have significantly improved outcomes for neurovascular and coronary pathologies. However, there remain some operational safety risks including the dosage of ionizing radiation due to fluoroscopic imaging, as well as complications due to inadvertent vessel puncture. Nitinol is a well-established biocompatible shape-memory alloy that may enable more degrees of freedom (DoF) in endovascular techniques. Additionally, diffuse optical tomography (DOT) and ultrasound are promising non-ionizing modalities that may be incorporated to validate instrument localization and thereby reduce radiation dose. I propose a compact DOT system assembled with affordable and accessible components capable of reconstructing the cross-sectional image of an off-center object within an opaque gelatin phantom within 10 % error in cross-sectional area from its specified area in CAD software. Additionally, I will describe a methodology of localizing subwavelength nitinol wires via ultrasound in the synthetic venous pathways of the right forearm of an anatomical manikin."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/13063"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Endovascular techniques.","Nitinol wires.","Ultrasound.","Non-ionizing imaging.","Diffuse optical tomography."],"dc:title":["Advancement of non-ionizing Imaging techniques for clinical applications : a compact diffuse optical tomography system and the ultrasound localization of subwavelength nitinol wires in anatomical manikin vasculature."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"person:identifier.orcid":["0009-0009-1817-5961"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.B.M.E."],"thesis:degree_program":["Biomedical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:22:25Z"}