{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/3905"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/3905","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"A new modality for microwave tomographic maging : transit time tomography.","abstract":"A new method for tomographic imaging using time delay of microwaves as they pass through objects of varying dielectric is presented. To obtain this delay measurement, recording of transmitted waveforms is performed when broadband microwave signals are sent through objects. The experimental setup consists of a circular table with vertically polarized bi-conic horns as transmitting and receiving antennas, with a Vector Network Analyzer as the excitation and measurement device. By obtaining multiple point tomographic projections at multiple angles, a reconstruction of the classic X-ray Radon transform is possible. Results obtained show accuracy and resolution limits to be within acceptable ranges and offer many new, less expensive possibilities for tomographic imaging.","abstract_html":"A new method for tomographic imaging using time delay of microwaves as they pass through objects of varying dielectric is presented. To obtain this delay measurement, recording of transmitted waveforms is performed when broadband microwave signals are sent through objects. The experimental setup consists of a circular table with vertically polarized bi-conic horns as transmitting and receiving antennas, with a Vector Network Analyzer as the excitation and measurement device. By obtaining multiple point tomographic projections at multiple angles, a reconstruction of the classic X-ray Radon transform is possible. Results obtained show accuracy and resolution limits to be within acceptable ranges and offer many new, less expensive possibilities for tomographic imaging.","abstract_has_math":false,"creators":["Trumbo, Matthew Lee."],"institution":"Baylor University.","degree_name":"M.S.E.C.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Marks, Robert J., II (Robert Jackson), 1950-","Jean, B. Randall."],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-05","date_published":"2006-05","updated_at":"2026-11-22T16:19:41Z","subjects":["Tomography -- Research.","Microwave imaging in medicine.","Diagnostic imaging."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/3905","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/3905","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F3905","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F3905","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marks, Robert J., II (Robert Jackson), 1950-","Jean, B. Randall."]},{"key":"dc:creator","label":"Author","values":["Trumbo, Matthew Lee."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-07-22T22:45:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-07-22T22:45:56Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2006"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-05"]},{"key":"dc:date.issued","label":"Date","values":["2006-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2006"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.E.C.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical & Computer Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Tomography -- Research.","Microwave imaging in medicine.","Diagnostic imaging."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/3905"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A new method for tomographic imaging using time delay of microwaves as they pass through objects of varying dielectric is presented. To obtain this delay measurement, recording of transmitted waveforms is performed when broadband microwave signals are sent through objects. The experimental setup consists of a circular table with vertically polarized bi-conic horns as transmitting and receiving antennas, with a Vector Network Analyzer as the excitation and measurement device. By obtaining multiple point tomographic projections at multiple angles, a reconstruction of the classic X-ray Radon transform is possible. Results obtained show accuracy and resolution limits to be within acceptable ranges and offer many new, less expensive possibilities for tomographic imaging."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A new modality for microwave tomographic maging : transit time tomography."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marks, Robert J., II (Robert Jackson), 1950-","Jean, B. Randall."],"dc:creator":["Trumbo, Matthew Lee."],"dc:date.accessioned":["2006-07-22T22:45:56Z"],"dc:date.available":["2006-07-22T22:45:56Z"],"dc:date.copyright":["2006"],"dc:date.created":["2006-05"],"dc:date.issued":["2006-05"],"dc:date.submitted":["May 2006"],"dc:description.abstract":["A new method for tomographic imaging using time delay of microwaves as they pass through objects of varying dielectric is presented. To obtain this delay measurement, recording of transmitted waveforms is performed when broadband microwave signals are sent through objects. The experimental setup consists of a circular table with vertically polarized bi-conic horns as transmitting and receiving antennas, with a Vector Network Analyzer as the excitation and measurement device. By obtaining multiple point tomographic projections at multiple angles, a reconstruction of the classic X-ray Radon transform is possible. Results obtained show accuracy and resolution limits to be within acceptable ranges and offer many new, less expensive possibilities for tomographic imaging."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/3905"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Tomography -- Research.","Microwave imaging in medicine.","Diagnostic imaging."],"dc:title":["A new modality for microwave tomographic maging : transit time tomography."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.E.C.E."],"thesis:degree_program":["Electrical & Computer Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:19:41Z"}