{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/4021"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/4021","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"A novel spectropolarimeter for determiation of sucrose and other optically active samples.","abstract":"Polarimetry and spectropolarimetry are important tools in the sugar industry and pharmaceutical research. Polarimetric measurements cannot be performed on colored samples because the presence of color interferes with the final reading. To avoid the effect of color in sugar samples, lead subacetate is added. Its use to decolorize sugar is problematic because lead is a pollutant. In this work, a novel spectropolarimeter based on an ordinary spectrophotometer is described for determination of sucrose and other optically active samples. The instrument has no moving parts, and optical rotation is encoded as apparent absorbance which makes it suitable for colored samples. Background correction before apparent absorbance measurements, combined with multivariate statistical analysis over a wide spectral range, proved efficient to avoid chemical pretreatment of the samples. The instrument showed good performance for sucrose predictions and multivariate enantiomeric discrimination.","abstract_html":"Polarimetry and spectropolarimetry are important tools in the sugar industry and pharmaceutical research. Polarimetric measurements cannot be performed on colored samples because the presence of color interferes with the final reading. To avoid the effect of color in sugar samples, lead subacetate is added. Its use to decolorize sugar is problematic because lead is a pollutant. In this work, a novel spectropolarimeter based on an ordinary spectrophotometer is described for determination of sucrose and other optically active samples. The instrument has no moving parts, and optical rotation is encoded as apparent absorbance which makes it suitable for colored samples. Background correction before apparent absorbance measurements, combined with multivariate statistical analysis over a wide spectral range, proved efficient to avoid chemical pretreatment of the samples. The instrument showed good performance for sucrose predictions and multivariate enantiomeric discrimination.","abstract_has_math":false,"creators":["Calleja-Amador, Carlos Enrique."],"institution":"Baylor University.","degree_name":"M.S.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Chemistry & Biochemistry.","school":null,"contributors":[],"advisors":["Busch, Kenneth W.","Busch, Marianna A."],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-05","date_published":"2006-05","updated_at":"2026-11-23T17:00:25Z","subjects":["Spectroscopy -- Research.","Regression analysis.","Sucrose -- Analysis."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/4021","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/4021","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F4021","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F4021","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Busch, Kenneth W.","Busch, Marianna A."]},{"key":"dc:creator","label":"Author","values":["Calleja-Amador, Carlos Enrique."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-07-25T15:34:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-07-25T15:34:19Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2006"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-05"]},{"key":"dc:date.issued","label":"Date","values":["2006-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2006"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["College of Arts & Sciences."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Chemistry & Biochemistry."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Chemistry."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Spectroscopy -- Research.","Regression analysis.","Sucrose -- Analysis."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/4021"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Polarimetry and spectropolarimetry are important tools in the sugar industry and pharmaceutical research. Polarimetric measurements cannot be performed on colored samples because the presence of color interferes with the final reading. To avoid the effect of color in sugar samples, lead subacetate is added. Its use to decolorize sugar is problematic because lead is a pollutant. In this work, a novel spectropolarimeter based on an ordinary spectrophotometer is described for determination of sucrose and other optically active samples. The instrument has no moving parts, and optical rotation is encoded as apparent absorbance which makes it suitable for colored samples. Background correction before apparent absorbance measurements, combined with multivariate statistical analysis over a wide spectral range, proved efficient to avoid chemical pretreatment of the samples. The instrument showed good performance for sucrose predictions and multivariate enantiomeric discrimination."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A novel spectropolarimeter for determiation of sucrose and other optically active samples."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Busch, Kenneth W.","Busch, Marianna A."],"dc:creator":["Calleja-Amador, Carlos Enrique."],"dc:date.accessioned":["2006-07-25T15:34:19Z"],"dc:date.available":["2006-07-25T15:34:19Z"],"dc:date.copyright":["2006"],"dc:date.created":["2006-05"],"dc:date.issued":["2006-05"],"dc:date.submitted":["May 2006"],"dc:description.abstract":["Polarimetry and spectropolarimetry are important tools in the sugar industry and pharmaceutical research. Polarimetric measurements cannot be performed on colored samples because the presence of color interferes with the final reading. To avoid the effect of color in sugar samples, lead subacetate is added. Its use to decolorize sugar is problematic because lead is a pollutant. In this work, a novel spectropolarimeter based on an ordinary spectrophotometer is described for determination of sucrose and other optically active samples. The instrument has no moving parts, and optical rotation is encoded as apparent absorbance which makes it suitable for colored samples. Background correction before apparent absorbance measurements, combined with multivariate statistical analysis over a wide spectral range, proved efficient to avoid chemical pretreatment of the samples. The instrument showed good performance for sucrose predictions and multivariate enantiomeric discrimination."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/4021"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Spectroscopy -- Research.","Regression analysis.","Sucrose -- Analysis."],"dc:title":["A novel spectropolarimeter for determiation of sucrose and other optically active samples."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["College of Arts & Sciences."],"thesis:degree_department":["Dept. of Chemistry & Biochemistry."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:degree_program":["Chemistry."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-23T17:00:25Z"}