{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/4956"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/4956","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"A microwave radiometer system for use in biomedical applications.","abstract":"The biomedical industry is a rapidly growing sector and demands are increasing for the production of safe and noninvasive technologies. With the current surge of diabetes, a very desirable application for these technologies is a non-invasive monitor for blood glucose level. Recently, microwave sensing has offered hope for safer diagnostic and therapeutic procedures. One specific sensing technique involves a microwave radiometer, which provides a purely passive measurement of naturally emitted electromagnetic radiation from material objects. A highly sensitive receiver, the radiometer can detect radiation for the purpose of obtaining useful information about a particular object, thus providing a safe tool for the biomedical industry. This thesis outlines the microwave properties of radiometry and presents the design of a microwave radiometer aimed at biomedical applications. Experimental results demonstrate the applicability and repeatability of the device, as well as its performance as a biomedical sensor.","abstract_html":"The biomedical industry is a rapidly growing sector and demands are increasing for the production of safe and noninvasive technologies. With the current surge of diabetes, a very desirable application for these technologies is a non-invasive monitor for blood glucose level. Recently, microwave sensing has offered hope for safer diagnostic and therapeutic procedures. One specific sensing technique involves a microwave radiometer, which provides a purely passive measurement of naturally emitted electromagnetic radiation from material objects. A highly sensitive receiver, the radiometer can detect radiation for the purpose of obtaining useful information about a particular object, thus providing a safe tool for the biomedical industry. This thesis outlines the microwave properties of radiometry and presents the design of a microwave radiometer aimed at biomedical applications. Experimental results demonstrate the applicability and repeatability of the device, as well as its performance as a biomedical sensor.","abstract_has_math":false,"creators":["Ballew, Laura R."],"institution":"Baylor University.","degree_name":"M.S.B.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Jean, B. Randall."],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-12","date_published":"2006-12","updated_at":"2026-11-22T16:19:41Z","subjects":["Radiometers -- Design and construction.","Microwave detectors -- Design and construction.","Biosensors -- Design and construction.","Blood sugar -- Measurement.","Glucose -- Measurement."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/4956","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/4956","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F4956","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F4956","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jean, B. Randall."]},{"key":"dc:creator","label":"Author","values":["Ballew, Laura R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-02-21T22:39:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-02-21T22:39:34Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2006"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-12"]},{"key":"dc:date.issued","label":"Date","values":["2006-12"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["December 2006"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.B.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Radiometers -- Design and construction.","Microwave detectors -- Design and construction.","Biosensors -- Design and construction.","Blood sugar -- Measurement.","Glucose -- Measurement."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/4956"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The biomedical industry is a rapidly growing sector and demands are increasing for the production of safe and noninvasive technologies. With the current surge of diabetes, a very desirable application for these technologies is a non-invasive monitor for blood glucose level. Recently, microwave sensing has offered hope for safer diagnostic and therapeutic procedures. One specific sensing technique involves a microwave radiometer, which provides a purely passive measurement of naturally emitted electromagnetic radiation from material objects. A highly sensitive receiver, the radiometer can detect radiation for the purpose of obtaining useful information about a particular object, thus providing a safe tool for the biomedical industry. This thesis outlines the microwave properties of radiometry and presents the design of a microwave radiometer aimed at biomedical applications. Experimental results demonstrate the applicability and repeatability of the device, as well as its performance as a biomedical sensor."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A microwave radiometer system for use in biomedical applications."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jean, B. Randall."],"dc:creator":["Ballew, Laura R."],"dc:date.accessioned":["2007-02-21T22:39:34Z"],"dc:date.available":["2007-02-21T22:39:34Z"],"dc:date.copyright":["2006"],"dc:date.created":["2006-12"],"dc:date.issued":["2006-12"],"dc:date.submitted":["December 2006"],"dc:description.abstract":["The biomedical industry is a rapidly growing sector and demands are increasing for the production of safe and noninvasive technologies. With the current surge of diabetes, a very desirable application for these technologies is a non-invasive monitor for blood glucose level. Recently, microwave sensing has offered hope for safer diagnostic and therapeutic procedures. One specific sensing technique involves a microwave radiometer, which provides a purely passive measurement of naturally emitted electromagnetic radiation from material objects. A highly sensitive receiver, the radiometer can detect radiation for the purpose of obtaining useful information about a particular object, thus providing a safe tool for the biomedical industry. This thesis outlines the microwave properties of radiometry and presents the design of a microwave radiometer aimed at biomedical applications. Experimental results demonstrate the applicability and repeatability of the device, as well as its performance as a biomedical sensor."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/4956"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Radiometers -- Design and construction.","Microwave detectors -- Design and construction.","Biosensors -- Design and construction.","Blood sugar -- Measurement.","Glucose -- Measurement."],"dc:title":["A microwave radiometer system for use in biomedical applications."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.B.M.E."],"thesis:degree_program":["Biomedical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:19:41Z"}