{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/5164"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/5164","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Calibration methodology for a microwave non-invasive glucose sensor.","abstract":"Non-invasive measuring techniques for determining biological parameters are more heavily researched with the growth of the biomedical industry. One of the top areas in non-invasive research deals with diabetes. This disease affects more than 20 million people in the United States, and there is an increasing desire to find a testing process that is non-invasive, easy to use, and safe for users. Microwave technology has improved greatly during recent years and is now seen more often in conjunction with biomedical research. Microwaves are capable of taking measurements of materials inside of a closed volume without the need to come into contact with the material. This makes them ideal for measuring biological parameters, specifically glucose concentrations in the blood. This thesis expands on the development of a microwave sensor to non-invasively measure blood glucose levels and will examine the possibility of developing a calibration for a device using the microwave sensor.","abstract_html":"Non-invasive measuring techniques for determining biological parameters are more heavily researched with the growth of the biomedical industry. One of the top areas in non-invasive research deals with diabetes. This disease affects more than 20 million people in the United States, and there is an increasing desire to find a testing process that is non-invasive, easy to use, and safe for users. Microwave technology has improved greatly during recent years and is now seen more often in conjunction with biomedical research. Microwaves are capable of taking measurements of materials inside of a closed volume without the need to come into contact with the material. This makes them ideal for measuring biological parameters, specifically glucose concentrations in the blood. This thesis expands on the development of a microwave sensor to non-invasively measure blood glucose levels and will examine the possibility of developing a calibration for a device using the microwave sensor.","abstract_has_math":false,"creators":["McClung, Melanie J."],"institution":"Baylor University.","degree_name":"M.S.B.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Jean, B. Randall."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-05","date_published":"2008-05","updated_at":"2026-11-22T16:24:43Z","subjects":["Microwave devices -- Calibration.","Biosensors -- Design and construction.","Glucose -- Measurement.","Blood sugar -- Measurement."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/5164","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/5164","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F5164","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F5164","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jean, B. Randall."]},{"key":"dc:creator","label":"Author","values":["McClung, Melanie J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-06-09T15:41:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-06-09T15:41:02Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2008"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2008-05"]},{"key":"dc:date.issued","label":"Date","values":["2008-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2008"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.B.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microwave devices -- Calibration.","Biosensors -- Design and construction.","Glucose -- Measurement.","Blood sugar -- Measurement."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/5164"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Non-invasive measuring techniques for determining biological parameters are more heavily researched with the growth of the biomedical industry. One of the top areas in non-invasive research deals with diabetes. This disease affects more than 20 million people in the United States, and there is an increasing desire to find a testing process that is non-invasive, easy to use, and safe for users. Microwave technology has improved greatly during recent years and is now seen more often in conjunction with biomedical research. Microwaves are capable of taking measurements of materials inside of a closed volume without the need to come into contact with the material. This makes them ideal for measuring biological parameters, specifically glucose concentrations in the blood. This thesis expands on the development of a microwave sensor to non-invasively measure blood glucose levels and will examine the possibility of developing a calibration for a device using the microwave sensor."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Calibration methodology for a microwave non-invasive glucose sensor."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jean, B. Randall."],"dc:creator":["McClung, Melanie J."],"dc:date.accessioned":["2008-06-09T15:41:02Z"],"dc:date.available":["2008-06-09T15:41:02Z"],"dc:date.copyright":["2008"],"dc:date.created":["2008-05"],"dc:date.issued":["2008-05"],"dc:date.submitted":["May 2008"],"dc:description.abstract":["Non-invasive measuring techniques for determining biological parameters are more heavily researched with the growth of the biomedical industry. One of the top areas in non-invasive research deals with diabetes. This disease affects more than 20 million people in the United States, and there is an increasing desire to find a testing process that is non-invasive, easy to use, and safe for users. Microwave technology has improved greatly during recent years and is now seen more often in conjunction with biomedical research. Microwaves are capable of taking measurements of materials inside of a closed volume without the need to come into contact with the material. This makes them ideal for measuring biological parameters, specifically glucose concentrations in the blood. This thesis expands on the development of a microwave sensor to non-invasively measure blood glucose levels and will examine the possibility of developing a calibration for a device using the microwave sensor."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/5164"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Microwave devices -- Calibration.","Biosensors -- Design and construction.","Glucose -- Measurement.","Blood sugar -- Measurement."],"dc:title":["Calibration methodology for a microwave non-invasive glucose sensor."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.B.M.E."],"thesis:degree_program":["Biomedical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:24:43Z"}