{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/5345"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/5345","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Determination of pharmaceuticals in fish and wastewater using isotope dilution high performance liquid chromatography-tandem mass spectrometry.","abstract":"A method has been developed for the trace analysis of 15 pharmaceuticals and employs liquid chromatography/tandem mass spectrometry (LC-ESI-MS/MS). Unlike many previous methods, which suffer from matrix suppression and recovery loss, the present method utilizes isotope dilution for each compound to correct for these phenomena. Matrix spike recoveries for all compounds were between 87 and 113% for wastewater effluent, 98 and 144% for fish fillet tissue, and 81% and 105% for fish liver tissue. Method Detection limits (MDLs) in wastewater, fish fillet, and liver tissue were ≤21, ≤13, and ≤41 ng/g, respectively for most analytes. Additionally, this method was directly compared with matrix matched calibration to evaluate potential to compensate for matrix effects. Matrix matched was not suitable to account for matrix effects in samples with highly loaded matrix such as fish liver, though this method offered greater sensitive compared to isotope dilution in the detection of some compounds such as norfluoxetine, sertraline, and fluoxetine.","abstract_html":"A method has been developed for the trace analysis of 15 pharmaceuticals and employs liquid chromatography/tandem mass spectrometry (LC-ESI-MS/MS). Unlike many previous methods, which suffer from matrix suppression and recovery loss, the present method utilizes isotope dilution for each compound to correct for these phenomena. Matrix spike recoveries for all compounds were between 87 and 113% for wastewater effluent, 98 and 144% for fish fillet tissue, and 81% and 105% for fish liver tissue. Method Detection limits (MDLs) in wastewater, fish fillet, and liver tissue were ≤21, ≤13, and ≤41 ng/g, respectively for most analytes. Additionally, this method was directly compared with matrix matched calibration to evaluate potential to compensate for matrix effects. Matrix matched was not suitable to account for matrix effects in samples with highly loaded matrix such as fish liver, though this method offered greater sensitive compared to isotope dilution in the detection of some compounds such as norfluoxetine, sertraline, and fluoxetine.","abstract_has_math":false,"creators":["Perez Hurtado, Pilar."],"institution":"Baylor University.","degree_name":"M.S.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Chemistry & Biochemistry.","school":null,"contributors":[],"advisors":["Chambliss, C. Kevin."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-05","date_published":"2009-05","updated_at":"2026-11-23T17:06:52Z","subjects":["Drugs -- Environmental aspects.","Drugs -- Toxicology.","Water -- Pollution.","Fishes -- Effect of water pollution on.","Fishes -- Physiology.","High performance liquid chromatography.","Mass spectrometry.","Isotope dilution analysis."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/5345","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/5345","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F5345","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F5345","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chambliss, C. Kevin."]},{"key":"dc:creator","label":"Author","values":["Perez Hurtado, Pilar."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-07-01T16:58:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-07-01T16:58:11Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2009"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-05"]},{"key":"dc:date.issued","label":"Date","values":["2009-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2009"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["College of Arts & Sciences."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Chemistry & Biochemistry."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Chemistry."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Drugs -- Environmental aspects.","Drugs -- Toxicology.","Water -- Pollution.","Fishes -- Effect of water pollution on.","Fishes -- Physiology.","High performance liquid chromatography.","Mass spectrometry.","Isotope dilution analysis."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/5345"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A method has been developed for the trace analysis of 15 pharmaceuticals and employs liquid chromatography/tandem mass spectrometry (LC-ESI-MS/MS). Unlike many previous methods, which suffer from matrix suppression and recovery loss, the present method utilizes isotope dilution for each compound to correct for these phenomena. Matrix spike recoveries for all compounds were between 87 and 113% for wastewater effluent, 98 and 144% for fish fillet tissue, and 81% and 105% for fish liver tissue. Method Detection limits (MDLs) in wastewater, fish fillet, and liver tissue were ≤21, ≤13, and ≤41 ng/g, respectively for most analytes. Additionally, this method was directly compared with matrix matched calibration to evaluate potential to compensate for matrix effects. Matrix matched was not suitable to account for matrix effects in samples with highly loaded matrix such as fish liver, though this method offered greater sensitive compared to isotope dilution in the detection of some compounds such as norfluoxetine, sertraline, and fluoxetine."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Determination of pharmaceuticals in fish and wastewater using isotope dilution high performance liquid chromatography-tandem mass spectrometry."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chambliss, C. Kevin."],"dc:creator":["Perez Hurtado, Pilar."],"dc:date.accessioned":["2009-07-01T16:58:11Z"],"dc:date.available":["2009-07-01T16:58:11Z"],"dc:date.copyright":["2009"],"dc:date.created":["2009-05"],"dc:date.issued":["2009-05"],"dc:date.submitted":["May 2009"],"dc:description.abstract":["A method has been developed for the trace analysis of 15 pharmaceuticals and employs liquid chromatography/tandem mass spectrometry (LC-ESI-MS/MS). Unlike many previous methods, which suffer from matrix suppression and recovery loss, the present method utilizes isotope dilution for each compound to correct for these phenomena. Matrix spike recoveries for all compounds were between 87 and 113% for wastewater effluent, 98 and 144% for fish fillet tissue, and 81% and 105% for fish liver tissue. Method Detection limits (MDLs) in wastewater, fish fillet, and liver tissue were ≤21, ≤13, and ≤41 ng/g, respectively for most analytes. Additionally, this method was directly compared with matrix matched calibration to evaluate potential to compensate for matrix effects. Matrix matched was not suitable to account for matrix effects in samples with highly loaded matrix such as fish liver, though this method offered greater sensitive compared to isotope dilution in the detection of some compounds such as norfluoxetine, sertraline, and fluoxetine."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/5345"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Drugs -- Environmental aspects.","Drugs -- Toxicology.","Water -- Pollution.","Fishes -- Effect of water pollution on.","Fishes -- Physiology.","High performance liquid chromatography.","Mass spectrometry.","Isotope dilution analysis."],"dc:title":["Determination of pharmaceuticals in fish and wastewater using isotope dilution high performance liquid chromatography-tandem mass spectrometry."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["College of Arts & Sciences."],"thesis:degree_department":["Dept. of Chemistry & Biochemistry."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:degree_program":["Chemistry."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-23T17:06:52Z"}