{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/5357"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/5357","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Design and validation of a solar domestic hot water heating simulator.","abstract":"A growing demand for emerging alternative energy technologies is fueled by rising energy prices and decreasing energy supplies. Domestic hot water heating is an industry that continues to benefit from increased research in and improvement of solar technology. This thesis outlines the implementation of a solar domestic water heating simulator and the validation of a double and single tank domestic hot water configuration. The results and procedures were compared to the guidelines of the Solar Rating and Certification Corporation's (SRCC) OG-300 standards. The Solar Energy Factor for a double-tank system was found to be 2.64 ±0.043 and for a single tank system 4.46 ±0.06, which is 12 % and 9 % respectively, below data reported by the SRCC for a comparable test. These tests will verify the performance of this solar water heating system and provide a baseline profile for further modifications to improve the efficiency of future solar domestic hot water heating systems.","abstract_html":"A growing demand for emerging alternative energy technologies is fueled by rising energy prices and decreasing energy supplies. Domestic hot water heating is an industry that continues to benefit from increased research in and improvement of solar technology. This thesis outlines the implementation of a solar domestic water heating simulator and the validation of a double and single tank domestic hot water configuration. The results and procedures were compared to the guidelines of the Solar Rating and Certification Corporation&#x27;s (SRCC) OG-300 standards. The Solar Energy Factor for a double-tank system was found to be 2.64 ±0.043 and for a single tank system 4.46 ±0.06, which is 12 % and 9 % respectively, below data reported by the SRCC for a comparable test. These tests will verify the performance of this solar water heating system and provide a baseline profile for further modifications to improve the efficiency of future solar domestic hot water heating systems.","abstract_has_math":false,"creators":["Cemo, Thomas A."],"institution":"Baylor University.","degree_name":"M.S.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Van Treuren, Kenneth W."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-05","date_published":"2009-05","updated_at":"2026-11-22T16:24:43Z","subjects":["Solar water heaters -- Testing.","Solar collectors -- Testing.","Hot-water heating -- Testing.","Solar thermal energy.","Solar houses.","Water heaters -- Energy conservation."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/5357","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/5357","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F5357","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F5357","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Van Treuren, Kenneth W."]},{"key":"dc:creator","label":"Author","values":["Cemo, Thomas A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-07-08T18:47:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-07-08T18:47:30Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2009"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-05"]},{"key":"dc:date.issued","label":"Date","values":["2009-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["May 2009"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Mechanical Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Mechanical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Solar water heaters -- Testing.","Solar collectors -- Testing.","Hot-water heating -- Testing.","Solar thermal energy.","Solar houses.","Water heaters -- Energy conservation."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/5357"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A growing demand for emerging alternative energy technologies is fueled by rising energy prices and decreasing energy supplies. Domestic hot water heating is an industry that continues to benefit from increased research in and improvement of solar technology. This thesis outlines the implementation of a solar domestic water heating simulator and the validation of a double and single tank domestic hot water configuration. The results and procedures were compared to the guidelines of the Solar Rating and Certification Corporation's (SRCC) OG-300 standards. The Solar Energy Factor for a double-tank system was found to be 2.64 ±0.043 and for a single tank system 4.46 ±0.06, which is 12 % and 9 % respectively, below data reported by the SRCC for a comparable test. These tests will verify the performance of this solar water heating system and provide a baseline profile for further modifications to improve the efficiency of future solar domestic hot water heating systems."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and validation of a solar domestic hot water heating simulator."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Van Treuren, Kenneth W."],"dc:creator":["Cemo, Thomas A."],"dc:date.accessioned":["2009-07-08T18:47:30Z"],"dc:date.available":["2009-07-08T18:47:30Z"],"dc:date.copyright":["2009"],"dc:date.created":["2009-05"],"dc:date.issued":["2009-05"],"dc:date.submitted":["May 2009"],"dc:description.abstract":["A growing demand for emerging alternative energy technologies is fueled by rising energy prices and decreasing energy supplies. Domestic hot water heating is an industry that continues to benefit from increased research in and improvement of solar technology. This thesis outlines the implementation of a solar domestic water heating simulator and the validation of a double and single tank domestic hot water configuration. The results and procedures were compared to the guidelines of the Solar Rating and Certification Corporation's (SRCC) OG-300 standards. The Solar Energy Factor for a double-tank system was found to be 2.64 ±0.043 and for a single tank system 4.46 ±0.06, which is 12 % and 9 % respectively, below data reported by the SRCC for a comparable test. These tests will verify the performance of this solar water heating system and provide a baseline profile for further modifications to improve the efficiency of future solar domestic hot water heating systems."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/5357"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Solar water heaters -- Testing.","Solar collectors -- Testing.","Hot-water heating -- Testing.","Solar thermal energy.","Solar houses.","Water heaters -- Energy conservation."],"dc:title":["Design and validation of a solar domestic hot water heating simulator."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Mechanical Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.M.E."],"thesis:degree_program":["Mechanical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:24:43Z"}