{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/5386"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/5386","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"The effects of freezing on the material properties and structure of bovine medial meniscus.","abstract":"Menisci serve as shock absorbers and stabilizers in the knee. Bovine meniscus is often used as a model for human meniscus because it is inexpensive and readily available. During experiments, the bovine menisci are usually frozen and thawed repeatedly to maintain freshness through specimen transport and during the study. Previous studies did not take into account the effects of multiple freezing and thawing cycles (FTCs) on the mechanical properties [32, 33, 35, 47]. The current study will observe the effects, if any, of repeated FTC‟s on the viscoelastic properties and structure of bovine meniscus. Five test groups were created consisting of five menisci each. After treatment, a plug was taken from each meniscus and compressed in a confined compression chamber for 20,000 seconds. Displacement and specimen dimensions were measured, and aggregate Modulus (HA) and tissue permeability (λ) were calculated. A scanning electron microscope (SEM) was used to view the structure.","abstract_html":"Menisci serve as shock absorbers and stabilizers in the knee. Bovine meniscus is often used as a model for human meniscus because it is inexpensive and readily available. During experiments, the bovine menisci are usually frozen and thawed repeatedly to maintain freshness through specimen transport and during the study. Previous studies did not take into account the effects of multiple freezing and thawing cycles (FTCs) on the mechanical properties [32, 33, 35, 47]. The current study will observe the effects, if any, of repeated FTC‟s on the viscoelastic properties and structure of bovine meniscus. Five test groups were created consisting of five menisci each. After treatment, a plug was taken from each meniscus and compressed in a confined compression chamber for 20,000 seconds. Displacement and specimen dimensions were measured, and aggregate Modulus (HA) and tissue permeability (λ) were calculated. A scanning electron microscope (SEM) was used to view the structure.","abstract_has_math":false,"creators":["Morgan, D. Scott."],"institution":"Baylor University.","degree_name":"M.S.B.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Skurla, Carolyn Patlovany."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-08","date_published":"2009-08","updated_at":"2026-11-22T16:19:14Z","subjects":["Meniscus (Anatomy) -- Effect of temperature on.","Viscoelastic materials -- Effect of temperature on.","Meniscus (Anatomy) -- Mechanical properties."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/5386","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/5386","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F5386","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F5386","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Skurla, Carolyn Patlovany."]},{"key":"dc:creator","label":"Author","values":["Morgan, D. Scott."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-08-25T16:20:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-08-25T16:20:28Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2009"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-08"]},{"key":"dc:date.issued","label":"Date","values":["2009-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2009"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Mechanical Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.B.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Meniscus (Anatomy) -- Effect of temperature on.","Viscoelastic materials -- Effect of temperature on.","Meniscus (Anatomy) -- Mechanical properties."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/5386"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Menisci serve as shock absorbers and stabilizers in the knee. Bovine meniscus is often used as a model for human meniscus because it is inexpensive and readily available. During experiments, the bovine menisci are usually frozen and thawed repeatedly to maintain freshness through specimen transport and during the study. Previous studies did not take into account the effects of multiple freezing and thawing cycles (FTCs) on the mechanical properties [32, 33, 35, 47]. The current study will observe the effects, if any, of repeated FTC‟s on the viscoelastic properties and structure of bovine meniscus. Five test groups were created consisting of five menisci each. After treatment, a plug was taken from each meniscus and compressed in a confined compression chamber for 20,000 seconds. Displacement and specimen dimensions were measured, and aggregate Modulus (HA) and tissue permeability (λ) were calculated. A scanning electron microscope (SEM) was used to view the structure."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The effects of freezing on the material properties and structure of bovine medial meniscus."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Skurla, Carolyn Patlovany."],"dc:creator":["Morgan, D. Scott."],"dc:date.accessioned":["2009-08-25T16:20:28Z"],"dc:date.available":["2009-08-25T16:20:28Z"],"dc:date.copyright":["2009"],"dc:date.created":["2009-08"],"dc:date.issued":["2009-08"],"dc:date.submitted":["August 2009"],"dc:description.abstract":["Menisci serve as shock absorbers and stabilizers in the knee. Bovine meniscus is often used as a model for human meniscus because it is inexpensive and readily available. During experiments, the bovine menisci are usually frozen and thawed repeatedly to maintain freshness through specimen transport and during the study. Previous studies did not take into account the effects of multiple freezing and thawing cycles (FTCs) on the mechanical properties [32, 33, 35, 47]. The current study will observe the effects, if any, of repeated FTC‟s on the viscoelastic properties and structure of bovine meniscus. Five test groups were created consisting of five menisci each. After treatment, a plug was taken from each meniscus and compressed in a confined compression chamber for 20,000 seconds. Displacement and specimen dimensions were measured, and aggregate Modulus (HA) and tissue permeability (λ) were calculated. A scanning electron microscope (SEM) was used to view the structure."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/5386"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Meniscus (Anatomy) -- Effect of temperature on.","Viscoelastic materials -- Effect of temperature on.","Meniscus (Anatomy) -- Mechanical properties."],"dc:title":["The effects of freezing on the material properties and structure of bovine medial meniscus."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Mechanical Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.B.M.E."],"thesis:degree_program":["Biomedical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:19:14Z"}