{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/8215"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/8215","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Design and modeling of a power conditioning system for the hybrid fuel-cell/turbine power plant.","abstract":"This thesis presents the model of a power conditioning system (PCS) for the hybrid direct fuel-cell with turbine (DFC/T) power plant. It regulates voltage, current and power transmitted from the hybrid DFC/T power plant to utility grid. The proposed system consists of DC/DC converters, a grid-connected sinusoidal pulse width modulation (SPWM) DC/AC inverter, and an LCL filter. To regulate and stabilize the DC link voltage, DC/DC converter with PI controller is adopted. With three-phase SPWM inverter, both active and reactive power flow can be controlled. Both conventional proportional integral (PI) and the improved fuzzy PI control schemes are proposed. The LCL filter can greatly reduce the current total harmonic distortion (THD). Theoretical analysis and modeling methodologies are presented. Simulation results validate the proposed system and demonstrate that the proposed PCS can follow a dynamic load and reduce the current THD to 1.65%, which is much lower than IEEE standard of 5%.","abstract_html":"This thesis presents the model of a power conditioning system (PCS) for the hybrid direct fuel-cell with turbine (DFC/T) power plant. It regulates voltage, current and power transmitted from the hybrid DFC/T power plant to utility grid. The proposed system consists of DC/DC converters, a grid-connected sinusoidal pulse width modulation (SPWM) DC/AC inverter, and an LCL filter. To regulate and stabilize the DC link voltage, DC/DC converter with PI controller is adopted. With three-phase SPWM inverter, both active and reactive power flow can be controlled. Both conventional proportional integral (PI) and the improved fuzzy PI control schemes are proposed. The LCL filter can greatly reduce the current total harmonic distortion (THD). Theoretical analysis and modeling methodologies are presented. Simulation results validate the proposed system and demonstrate that the proposed PCS can follow a dynamic load and reduce the current THD to 1.65%, which is much lower than IEEE standard of 5%.","abstract_has_math":false,"creators":["Guo, Zhitong, 1987-"],"institution":"Baylor University.","degree_name":"M.S.E.C.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Lee, Kwang Y."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-08","date_published":"2011-08","updated_at":"2026-11-22T16:19:14Z","subjects":["Power conditioning system (PCS)","Hybrid direct fuel-cell.","Turbine power plant."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/8215","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/8215","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F8215","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F8215","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lee, Kwang Y."]},{"key":"dc:creator","label":"Author","values":["Guo, Zhitong, 1987-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-09-14T12:44:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-09-14T12:44:52Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2011"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-08"]},{"key":"dc:date.issued","label":"Date","values":["2011-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2011"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.E.C.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical & Computer Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Power conditioning system (PCS)","Hybrid direct fuel-cell.","Turbine power plant."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/8215"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the model of a power conditioning system (PCS) for the hybrid direct fuel-cell with turbine (DFC/T) power plant. It regulates voltage, current and power transmitted from the hybrid DFC/T power plant to utility grid. The proposed system consists of DC/DC converters, a grid-connected sinusoidal pulse width modulation (SPWM) DC/AC inverter, and an LCL filter. To regulate and stabilize the DC link voltage, DC/DC converter with PI controller is adopted. With three-phase SPWM inverter, both active and reactive power flow can be controlled. Both conventional proportional integral (PI) and the improved fuzzy PI control schemes are proposed. The LCL filter can greatly reduce the current total harmonic distortion (THD). Theoretical analysis and modeling methodologies are presented. Simulation results validate the proposed system and demonstrate that the proposed PCS can follow a dynamic load and reduce the current THD to 1.65%, which is much lower than IEEE standard of 5%."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and modeling of a power conditioning system for the hybrid fuel-cell/turbine power plant."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lee, Kwang Y."],"dc:creator":["Guo, Zhitong, 1987-"],"dc:date.accessioned":["2011-09-14T12:44:52Z"],"dc:date.available":["2011-09-14T12:44:52Z"],"dc:date.copyright":["2011"],"dc:date.created":["2011-08"],"dc:date.issued":["2011-08"],"dc:date.submitted":["August 2011"],"dc:description.abstract":["This thesis presents the model of a power conditioning system (PCS) for the hybrid direct fuel-cell with turbine (DFC/T) power plant. It regulates voltage, current and power transmitted from the hybrid DFC/T power plant to utility grid. The proposed system consists of DC/DC converters, a grid-connected sinusoidal pulse width modulation (SPWM) DC/AC inverter, and an LCL filter. To regulate and stabilize the DC link voltage, DC/DC converter with PI controller is adopted. With three-phase SPWM inverter, both active and reactive power flow can be controlled. Both conventional proportional integral (PI) and the improved fuzzy PI control schemes are proposed. The LCL filter can greatly reduce the current total harmonic distortion (THD). Theoretical analysis and modeling methodologies are presented. Simulation results validate the proposed system and demonstrate that the proposed PCS can follow a dynamic load and reduce the current THD to 1.65%, which is much lower than IEEE standard of 5%."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/8215"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Power conditioning system (PCS)","Hybrid direct fuel-cell.","Turbine power plant."],"dc:title":["Design and modeling of a power conditioning system for the hybrid fuel-cell/turbine power plant."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.E.C.E."],"thesis:degree_program":["Electrical & Computer Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:19:14Z"}