{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/8229"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/8229","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Design, analysis and simulation of a new current controller for wind power generation system using proportional plus resonance control.","abstract":"This thesis presents design, analysis and simulation of a new current control scheme for wind power generation system (WPGS). Proportional plus resonance (PR) controller is proposed to improve the accuracy of the control loop. Adding a current sensor at the capacitor filter instead of the damping resistor, the proposed two-current loop controller overcomes the instability of the system caused by the LCL filter and minimizes the power loss on the damping resistor (usually 0.8% of rated power). When the impedance of the grid is changing, the proposed current controller still keeps system stable with phase margins more than 45 degree. Moreover, using the proposed current controller, voltage transient characteristics of WPGS are analyzed and a control scheme is introduced to meet the low-voltage ride-through standard. All analysis and evaluation have been conducted for a 250kW WPGS with 208V grid voltage.","abstract_html":"This thesis presents design, analysis and simulation of a new current control scheme for wind power generation system (WPGS). Proportional plus resonance (PR) controller is proposed to improve the accuracy of the control loop. Adding a current sensor at the capacitor filter instead of the damping resistor, the proposed two-current loop controller overcomes the instability of the system caused by the LCL filter and minimizes the power loss on the damping resistor (usually 0.8% of rated power). When the impedance of the grid is changing, the proposed current controller still keeps system stable with phase margins more than 45 degree. Moreover, using the proposed current controller, voltage transient characteristics of WPGS are analyzed and a control scheme is introduced to meet the low-voltage ride-through standard. All analysis and evaluation have been conducted for a 250kW WPGS with 208V grid voltage.","abstract_has_math":false,"creators":["Liu, Bochuan, 1986-"],"institution":"Baylor University.","degree_name":"M.S.E.C.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Electrical & Computer Engineering.","school":null,"contributors":[],"advisors":["Song, Byeong-Mun."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-08","date_published":"2011-08","updated_at":"2026-11-22T16:24:43Z","subjects":["Current controller.","Wind power generation system.","Proportional plus resonance control."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/8229","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/8229","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F8229","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F8229","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Song, Byeong-Mun."]},{"key":"dc:creator","label":"Author","values":["Liu, Bochuan, 1986-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-09-14T12:58:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-09-14T12:58:21Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2011"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-08"]},{"key":"dc:date.issued","label":"Date","values":["2011-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2011"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Electrical & Computer Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.E.C.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Electrical & Computer Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Current controller.","Wind power generation system.","Proportional plus resonance control."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/8229"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents design, analysis and simulation of a new current control scheme for wind power generation system (WPGS). Proportional plus resonance (PR) controller is proposed to improve the accuracy of the control loop. Adding a current sensor at the capacitor filter instead of the damping resistor, the proposed two-current loop controller overcomes the instability of the system caused by the LCL filter and minimizes the power loss on the damping resistor (usually 0.8% of rated power). When the impedance of the grid is changing, the proposed current controller still keeps system stable with phase margins more than 45 degree. Moreover, using the proposed current controller, voltage transient characteristics of WPGS are analyzed and a control scheme is introduced to meet the low-voltage ride-through standard. All analysis and evaluation have been conducted for a 250kW WPGS with 208V grid voltage."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design, analysis and simulation of a new current controller for wind power generation system using proportional plus resonance control."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Song, Byeong-Mun."],"dc:creator":["Liu, Bochuan, 1986-"],"dc:date.accessioned":["2011-09-14T12:58:21Z"],"dc:date.available":["2011-09-14T12:58:21Z"],"dc:date.copyright":["2011"],"dc:date.created":["2011-08"],"dc:date.issued":["2011-08"],"dc:date.submitted":["August 2011"],"dc:description.abstract":["This thesis presents design, analysis and simulation of a new current control scheme for wind power generation system (WPGS). Proportional plus resonance (PR) controller is proposed to improve the accuracy of the control loop. Adding a current sensor at the capacitor filter instead of the damping resistor, the proposed two-current loop controller overcomes the instability of the system caused by the LCL filter and minimizes the power loss on the damping resistor (usually 0.8% of rated power). When the impedance of the grid is changing, the proposed current controller still keeps system stable with phase margins more than 45 degree. Moreover, using the proposed current controller, voltage transient characteristics of WPGS are analyzed and a control scheme is introduced to meet the low-voltage ride-through standard. All analysis and evaluation have been conducted for a 250kW WPGS with 208V grid voltage."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/8229"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Current controller.","Wind power generation system.","Proportional plus resonance control."],"dc:title":["Design, analysis and simulation of a new current controller for wind power generation system using proportional plus resonance control."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Electrical & Computer Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.E.C.E."],"thesis:degree_program":["Electrical & Computer Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:24:43Z"}