{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/8522"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/8522","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Response of passive surface hairs in steady and unsteady Falkner-Skan boundary layers.","abstract":"Arrays of biologically inspired artificial hair sensors for flow detection are being considered to provide small unmanned aerial vehicles greater platform stability through gust mitigation. Analytical models of hair sensor response to flow conditions have been previously developed, but fundamental assumptions of those models have remained essentially unvalidated. A model adaptation for non-wall-orthogonal fiber deflection was developed due to the geometric nature of the attached fibers. The current work seeks to validate this hair sensor model with wind tunnel testing results of hair sensor response to flows. Because the hair sensor arrays are not yet active, an optical fiber displacement measurement scheme and image analysis algorithms were developed to compute fiber deflection response to steady and unsteady flow conditions. Results indicate agreement between model predictions and experimental results sufficient for future sensor design employing the adapted model.","abstract_html":"Arrays of biologically inspired artificial hair sensors for flow detection are being considered to provide small unmanned aerial vehicles greater platform stability through gust mitigation. Analytical models of hair sensor response to flow conditions have been previously developed, but fundamental assumptions of those models have remained essentially unvalidated. A model adaptation for non-wall-orthogonal fiber deflection was developed due to the geometric nature of the attached fibers. The current work seeks to validate this hair sensor model with wind tunnel testing results of hair sensor response to flows. Because the hair sensor arrays are not yet active, an optical fiber displacement measurement scheme and image analysis algorithms were developed to compute fiber deflection response to steady and unsteady flow conditions. Results indicate agreement between model predictions and experimental results sufficient for future sensor design employing the adapted model.","abstract_has_math":false,"creators":["Case, Lance C."],"institution":"Baylor University.","degree_name":"M.S.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["McClain, Stephen Taylor."],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-08","date_published":"2012-08","updated_at":"2026-11-22T16:22:25Z","subjects":["Hair sensors.","Flow detection."],"languages":["en"],"rights":["Worldwide access","Redacted Version","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/8522","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/8522","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F8522","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F8522","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["McClain, Stephen Taylor."]},{"key":"dc:creator","label":"Author","values":["Case, Lance C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-11-29T16:26:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-29T16:26:13Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2012"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2012-08"]},{"key":"dc:date.issued","label":"Date","values":["2012-08"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["August 2012"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Mechanical Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Mechanical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hair sensors.","Flow detection."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access","Redacted Version"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/8522"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Arrays of biologically inspired artificial hair sensors for flow detection are being considered to provide small unmanned aerial vehicles greater platform stability through gust mitigation. Analytical models of hair sensor response to flow conditions have been previously developed, but fundamental assumptions of those models have remained essentially unvalidated. A model adaptation for non-wall-orthogonal fiber deflection was developed due to the geometric nature of the attached fibers. The current work seeks to validate this hair sensor model with wind tunnel testing results of hair sensor response to flows. Because the hair sensor arrays are not yet active, an optical fiber displacement measurement scheme and image analysis algorithms were developed to compute fiber deflection response to steady and unsteady flow conditions. Results indicate agreement between model predictions and experimental results sufficient for future sensor design employing the adapted model."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Response of passive surface hairs in steady and unsteady Falkner-Skan boundary layers."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["McClain, Stephen Taylor."],"dc:creator":["Case, Lance C."],"dc:date.accessioned":["2012-11-29T16:26:13Z"],"dc:date.available":["2012-11-29T16:26:13Z"],"dc:date.copyright":["2012"],"dc:date.created":["2012-08"],"dc:date.issued":["2012-08"],"dc:date.submitted":["August 2012"],"dc:description.abstract":["Arrays of biologically inspired artificial hair sensors for flow detection are being considered to provide small unmanned aerial vehicles greater platform stability through gust mitigation. Analytical models of hair sensor response to flow conditions have been previously developed, but fundamental assumptions of those models have remained essentially unvalidated. A model adaptation for non-wall-orthogonal fiber deflection was developed due to the geometric nature of the attached fibers. The current work seeks to validate this hair sensor model with wind tunnel testing results of hair sensor response to flows. Because the hair sensor arrays are not yet active, an optical fiber displacement measurement scheme and image analysis algorithms were developed to compute fiber deflection response to steady and unsteady flow conditions. Results indicate agreement between model predictions and experimental results sufficient for future sensor design employing the adapted model."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/8522"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access","Redacted Version"],"dc:subject":["Hair sensors.","Flow detection."],"dc:title":["Response of passive surface hairs in steady and unsteady Falkner-Skan boundary layers."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Mechanical Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.M.E."],"thesis:degree_program":["Mechanical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:22:25Z"}