{"id":{"repo_id":"baylor","oai_identifier":"oai:baylor-ir.tdl.org:2104/8812"},"canonical_url":"https://search.ndltd.org/etd/baylor/oai:baylor-ir.tdl.org:2104/8812","repository":{"repo_id":"baylor","name":"Baylor University","base_url":"https://baylor-ir.tdl.org/server/oai/request"},"display":{"title":"Effects of the glenohumeral joint center on the role of the middle deltoid : implications for reverse total shoulder arthroplasty.","abstract":"For shoulders with rotator cuff damage, the reverse shoulder replacement medializes the center of glenohumeral joint rotation, lending larger moment arms to undamaged muscles like the deltoid. The aim of this thesis was to create and use a computational model of the glenohumeral joint with an adjustable joint center to investigate and quantify the role of its position on middle deltoid moment arms for coronal plane abduction. The model confirmed that muscle moment arms increase as the center of rotation is shifted medially or inferiorly from the anatomical position. Specifically, medial translation of the glenohumeral center increased moment arms at low abduction angles while inferior shifts increased moment arms at high angles. Excursions of the middle deltoid were found to increase linearly as the joint center was moved medially or inferiorly: 1 mm medial translation or 1.33 mm inferior translation caused about 1 mm of increase in muscle excursion.","abstract_html":"For shoulders with rotator cuff damage, the reverse shoulder replacement medializes the center of glenohumeral joint rotation, lending larger moment arms to undamaged muscles like the deltoid. The aim of this thesis was to create and use a computational model of the glenohumeral joint with an adjustable joint center to investigate and quantify the role of its position on middle deltoid moment arms for coronal plane abduction. The model confirmed that muscle moment arms increase as the center of rotation is shifted medially or inferiorly from the anatomical position. Specifically, medial translation of the glenohumeral center increased moment arms at low abduction angles while inferior shifts increased moment arms at high angles. Excursions of the middle deltoid were found to increase linearly as the joint center was moved medially or inferiorly: 1 mm medial translation or 1.33 mm inferior translation caused about 1 mm of increase in muscle excursion.","abstract_has_math":false,"creators":["Bitter, Jonathan H."],"institution":"Baylor University.","degree_name":"M.S.B.M.E.","degree_level":"Masters","degree_discipline":null,"degree_department":"Dept. of Mechanical Engineering.","school":null,"contributors":[],"advisors":["Garner, Brian Alan, 1966-"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-09","date_published":"2013-09","updated_at":"2026-11-22T16:19:41Z","subjects":["Biomedical.","Orthopedics.","Arthroplasty.","Shoulder mechanics.","Reverse shoulder arthroplasty.","Tendon excursion.","Middle deltoid.","Moment arms.","Muscle excursion."],"languages":["en"],"rights":["Worldwide access","Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2104/8812","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2104/8812","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abaylor%3Aoai%3Abaylor-ir.tdl.org%3A2104%2F8812","prefix":"oai_dc"},"source_record":{"url":"https://baylor-ir.tdl.org/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Abaylor-ir.tdl.org%3A2104%2F8812","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Garner, Brian Alan, 1966-"]},{"key":"dc:creator","label":"Author","values":["Bitter, Jonathan H."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-09-24T14:06:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-09-24T14:06:58Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2013"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-09"]},{"key":"dc:date.issued","label":"Date","values":["2013-09"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["September 2013"]},{"key":"dc:type","label":"Dc Type","values":["Thesis","text"]},{"key":"thesis:degree_college","label":"Thesis Degree College","values":["School of Engineering & Computer Science."]},{"key":"thesis:degree_department","label":"Department","values":["Dept. of Mechanical Engineering."]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.B.M.E."]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Biomedical Engineering."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Baylor University."]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical.","Orthopedics.","Arthroplasty.","Shoulder mechanics.","Reverse shoulder arthroplasty.","Tendon excursion.","Middle deltoid.","Moment arms.","Muscle excursion."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["Worldwide access"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2104/8812"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["For shoulders with rotator cuff damage, the reverse shoulder replacement medializes the center of glenohumeral joint rotation, lending larger moment arms to undamaged muscles like the deltoid. The aim of this thesis was to create and use a computational model of the glenohumeral joint with an adjustable joint center to investigate and quantify the role of its position on middle deltoid moment arms for coronal plane abduction. The model confirmed that muscle moment arms increase as the center of rotation is shifted medially or inferiorly from the anatomical position. Specifically, medial translation of the glenohumeral center increased moment arms at low abduction angles while inferior shifts increased moment arms at high angles. Excursions of the middle deltoid were found to increase linearly as the joint center was moved medially or inferiorly: 1 mm medial translation or 1.33 mm inferior translation caused about 1 mm of increase in muscle excursion."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Effects of the glenohumeral joint center on the role of the middle deltoid : implications for reverse total shoulder arthroplasty."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Garner, Brian Alan, 1966-"],"dc:creator":["Bitter, Jonathan H."],"dc:date.accessioned":["2013-09-24T14:06:58Z"],"dc:date.available":["2013-09-24T14:06:58Z"],"dc:date.copyright":["2013"],"dc:date.created":["2013-09"],"dc:date.issued":["2013-09"],"dc:date.submitted":["September 2013"],"dc:description.abstract":["For shoulders with rotator cuff damage, the reverse shoulder replacement medializes the center of glenohumeral joint rotation, lending larger moment arms to undamaged muscles like the deltoid. The aim of this thesis was to create and use a computational model of the glenohumeral joint with an adjustable joint center to investigate and quantify the role of its position on middle deltoid moment arms for coronal plane abduction. The model confirmed that muscle moment arms increase as the center of rotation is shifted medially or inferiorly from the anatomical position. Specifically, medial translation of the glenohumeral center increased moment arms at low abduction angles while inferior shifts increased moment arms at high angles. Excursions of the middle deltoid were found to increase linearly as the joint center was moved medially or inferiorly: 1 mm medial translation or 1.33 mm inferior translation caused about 1 mm of increase in muscle excursion."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/2104/8812"],"dc:language.iso":["en"],"dc:rights":["Baylor University works are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. Contact libraryquestions@baylor.edu for inquiries about permission."],"dc:rights.accessrights":["Worldwide access"],"dc:subject":["Biomedical.","Orthopedics.","Arthroplasty.","Shoulder mechanics.","Reverse shoulder arthroplasty.","Tendon excursion.","Middle deltoid.","Moment arms.","Muscle excursion."],"dc:title":["Effects of the glenohumeral joint center on the role of the middle deltoid : implications for reverse total shoulder arthroplasty."],"dc:type":["Thesis","text"],"others:access_status":["open.access"],"thesis:degree_college":["School of Engineering & Computer Science."],"thesis:degree_department":["Dept. of Mechanical Engineering."],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.B.M.E."],"thesis:degree_program":["Biomedical Engineering."],"thesis:institution_name":["Baylor University."]},"updated_at":"2026-11-22T16:19:41Z"}