{"id":{"repo_id":"bielefeld","oai_identifier":"oai:pub.uni-bielefeld.de:2301284"},"canonical_url":"https://search.ndltd.org/etd/bielefeld/oai:pub.uni-bielefeld.de:2301284","repository":{"repo_id":"bielefeld","name":"Universität Bielefeld","base_url":"https://pub.uni-bielefeld.de/oai"},"display":{"title":"Entwicklung eines SMI-Mikroskops zur Präzisions-Strukturanalyse in vitalen biologischen Systemen","abstract":"Methods in light optical microscopy developed during the last years allow the establishment of optical resolutions far below the conventional diffraction limit. This has made new areas for the analysis of structural characteristics of subchromosomal complexes accessible. In this thesis, SMI-microscopic procedures for the high precision determination of biological nanostructures are enhanced, adapting this technique to the study of live cells and testing its applicability for such in-vivo procedures. By using spatially modulated illumination, SMI microscopy achieves an increase of the information content for object structures with dimensions below the conventional resolution. For the implementation of live cell measurements a completely new microscope setup was built and accurate characterisation and optimisation procedures were developed. This implied the integration of different hardware components and their adjustment within the optical configuration. Furthermore, the system properties under in-vivo conditions were determined, by what confiding size measurements up to least extensions of 40nm verified and precise conclusions about dynamical objects could be given. Subsequent, a live cell analysis concerning the influence of destructive manifesting fixation procedures was accomplished.","abstract_html":"Methods in light optical microscopy developed during the last years allow the establishment of optical resolutions far below the conventional diffraction limit. This has made new areas for the analysis of structural characteristics of subchromosomal complexes accessible. In this thesis, SMI-microscopic procedures for the high precision determination of biological nanostructures are enhanced, adapting this technique to the study of live cells and testing its applicability for such in-vivo procedures. By using spatially modulated illumination, SMI microscopy achieves an increase of the information content for object structures with dimensions below the conventional resolution. For the implementation of live cell measurements a completely new microscope setup was built and accurate characterisation and optimisation procedures were developed. This implied the integration of different hardware components and their adjustment within the optical configuration. Furthermore, the system properties under in-vivo conditions were determined, by what confiding size measurements up to least extensions of 40nm verified and precise conclusions about dynamical objects could be given. Subsequent, a live cell analysis concerning the influence of destructive manifesting fixation procedures was accomplished.","abstract_has_math":false,"creators":["Reymann, Jürgen"],"institution":"Universität Bielefeld","degree_name":null,"degree_level":"thesis.doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-27T02:22:32Z","subjects":[],"languages":["ger"],"rights":["free"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Reymann J. <em>Entwicklung eines SMI-Mikroskops zur Präzisions-Strukturanalyse in vitalen biologischen Systemen</em>. Bielefeld (Germany): Bielefeld University; 2008."],"render_values":[{"text":"Reymann J. <em>Entwicklung eines SMI-Mikroskops zur Präzisions-Strukturanalyse in vitalen biologischen Systemen</em>. Bielefeld (Germany): Bielefeld University; 2008.","href":null,"code":true}]},{"key":"dc:publisher.identifier","label":"Dc Publisher Identifier","values":["24060-6"],"render_values":[{"text":"24060-6","href":null,"code":true}]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["24060-6"],"render_values":[{"text":"24060-6","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://nbn-resolving.org/urn:nbn:de:hbz:361-12448","outbound_label":"Persistent identifier","outbound_source":"dc:identifier.urn","record_url":"https://nbn-resolving.org/urn:nbn:de:hbz:361-12448","record_label":"Repository record","record_kind":"pid","record_source":"dc:identifier.urn","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abielefeld%3Aoai%3Apub.uni-bielefeld.de%3A2301284","prefix":"oai_dc"},"source_record":{"url":"https://pub.uni-bielefeld.de/oai?verb=GetRecord&metadataPrefix=xMetaDissPlus&identifier=oai%3Apub.uni-bielefeld.de%3A2301284","prefix":"xMetaDissPlus"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Reymann, Jürgen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.dateaccepted","label":"Dc Date Dateaccepted","values":["2008-01-30"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Universitätsbibliothek Bielefeld"]},{"key":"dc:publisher.address","label":"Dc Publisher Address","values":["Universitätsstr. 25, 33615 Bielefeld"]},{"key":"dc:publisher.country","label":"Dc Publisher Country","values":["DE"]},{"key":"dc:publisher.identifier","label":"Dc Publisher Identifier","values":["24060-6"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Bielefeld"]},{"key":"dc:type","label":"Dc Type","values":["doctoralThesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"dc:type.version","label":"Dc Type Version","values":["publishedVersion"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis.doctoral"]},{"key":"thesis:institution_country","label":"Thesis Institution Country","values":["DE"]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["24060-6"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Universität Bielefeld"]},{"key":"thesis:institution_place","label":"Thesis Institution Place","values":["Bielefeld"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.ddc","label":"Dc Subject Ddc","values":["530"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["ger"]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["free"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Reymann J. <em>Entwicklung eines SMI-Mikroskops zur Präzisions-Strukturanalyse in vitalen biologischen Systemen</em>. Bielefeld (Germany): Bielefeld University; 2008."]},{"key":"dc:identifier.fulltext","label":"Full Text Identifier","values":["https://pub.uni-bielefeld.de/record/2301284"]},{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:hbz:361-12448"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Methods in light optical microscopy developed during the last years allow the establishment of optical resolutions far below the conventional diffraction limit. This has made new areas for the analysis of structural characteristics of subchromosomal complexes accessible. In this thesis, SMI-microscopic procedures for the high precision determination of biological nanostructures are enhanced, adapting this technique to the study of live cells and testing its applicability for such in-vivo procedures. By using spatially modulated illumination, SMI microscopy achieves an increase of the information content for object structures with dimensions below the conventional resolution. For the implementation of live cell measurements a completely new microscope setup was built and accurate characterisation and optimisation procedures were developed. This implied the integration of different hardware components and their adjustment within the optical configuration. Furthermore, the system properties under in-vivo conditions were determined, by what confiding size measurements up to least extensions of 40nm verified and precise conclusions about dynamical objects could be given. Subsequent, a live cell analysis concerning the influence of destructive manifesting fixation procedures was accomplished."]},{"key":"dc:format.fileid","label":"Dc Format Fileid","values":["2301287"]},{"key":"dc:format.filename","label":"Dc Format Filename","values":["Dissertation_JuergenReymann.pdf"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Entwicklung eines SMI-Mikroskops zur Präzisions-Strukturanalyse in vitalen biologischen Systemen"]},{"key":"ddb:contactid","label":"Ddb Contactid","values":["L6000-0538"]},{"key":"ddb:filenumber","label":"Ddb Filenumber","values":["1"]},{"key":"ddb:fileproperties","label":"Ddb Fileproperties","values":["aus: Praesentationsformat"]}]}],"canonical_facts":{"dc:creator":["Reymann, Jürgen"],"dc:date.dateaccepted":["2008-01-30"],"dc:date.issued":["2008"],"dc:description.abstract":["Methods in light optical microscopy developed during the last years allow the establishment of optical resolutions far below the conventional diffraction limit. This has made new areas for the analysis of structural characteristics of subchromosomal complexes accessible. In this thesis, SMI-microscopic procedures for the high precision determination of biological nanostructures are enhanced, adapting this technique to the study of live cells and testing its applicability for such in-vivo procedures. By using spatially modulated illumination, SMI microscopy achieves an increase of the information content for object structures with dimensions below the conventional resolution. For the implementation of live cell measurements a completely new microscope setup was built and accurate characterisation and optimisation procedures were developed. This implied the integration of different hardware components and their adjustment within the optical configuration. Furthermore, the system properties under in-vivo conditions were determined, by what confiding size measurements up to least extensions of 40nm verified and precise conclusions about dynamical objects could be given. Subsequent, a live cell analysis concerning the influence of destructive manifesting fixation procedures was accomplished."],"dc:format.fileid":["2301287"],"dc:format.filename":["Dissertation_JuergenReymann.pdf"],"dc:format.medium":["application/pdf"],"dc:identifier.citation":["Reymann J. <em>Entwicklung eines SMI-Mikroskops zur Präzisions-Strukturanalyse in vitalen biologischen Systemen</em>. Bielefeld (Germany): Bielefeld University; 2008."],"dc:identifier.fulltext":["https://pub.uni-bielefeld.de/record/2301284"],"dc:identifier.urn":["urn:nbn:de:hbz:361-12448"],"dc:language.dcterms_iso639_2":["ger"],"dc:publisher":["Universitätsbibliothek Bielefeld"],"dc:publisher.address":["Universitätsstr. 25, 33615 Bielefeld"],"dc:publisher.country":["DE"],"dc:publisher.identifier":["24060-6"],"dc:publisher.place":["Bielefeld"],"dc:rights.accessrights":["free"],"dc:subject.ddc":["530"],"dc:title":["Entwicklung eines SMI-Mikroskops zur Präzisions-Strukturanalyse in vitalen biologischen Systemen"],"dc:type":["doctoralThesis"],"dc:type.dcmitype":["Text"],"dc:type.version":["publishedVersion"],"ddb:contactid":["L6000-0538"],"ddb:filenumber":["1"],"ddb:fileproperties":["aus: Praesentationsformat"],"thesis:degree_level":["thesis.doctoral"],"thesis:institution_country":["DE"],"thesis:institution_identifier":["24060-6"],"thesis:institution_name":["Universität Bielefeld"],"thesis:institution_place":["Bielefeld"]},"updated_at":"2026-11-27T02:22:32Z"}