{"id":{"repo_id":"bielefeld","oai_identifier":"oai:pub.uni-bielefeld.de:2306435"},"canonical_url":"https://search.ndltd.org/etd/bielefeld/oai:pub.uni-bielefeld.de:2306435","repository":{"repo_id":"bielefeld","name":"Universität Bielefeld","base_url":"https://pub.uni-bielefeld.de/oai"},"display":{"title":"Realization of TMR devices in an industrial environment","abstract":"Magnetoresistive sensors are widely used in sensor applications for magnetic field measurements. Currently these sensors mostly use the Anisotropic Magnetoresistive Effect (AMR) or the Giant Magnetoresistive Effect (GMR). Due to their unique properties sensors based on the TMR effect could be advantageous: They offer a higher MR-ratio, smaller lateral dimensions and a higher resistance which reduces the power consumption. The work presented here is a purely industrial work, i.e. all experiments were performed directly on production tools at Sensitec GmbH in Mainz. In contrast to university research the focus was shifted to reproducibility and wafer uniformity instead of creating single perfect samples. In this thesis a TMR layer stack consisting of sputtered CoFeB electrodes, one of them being exchange-coupled with IrMn, and an ion beam deposited MgO barrier is presented. This system was studied by many research groups and is now transferred to an industrial environment. In contrast to most publications, the MgO barrier is being prepared by ion beam deposition, a novel preparation method for TMR stacks. Additionally Co2MnSi films for the use as potential electrodes were prepared by ion beam deposition and characterized structurally and magnetically.","abstract_html":"Magnetoresistive sensors are widely used in sensor applications for magnetic field measurements. Currently these sensors mostly use the Anisotropic Magnetoresistive Effect (AMR) or the Giant Magnetoresistive Effect (GMR). Due to their unique properties sensors based on the TMR effect could be advantageous: They offer a higher MR-ratio, smaller lateral dimensions and a higher resistance which reduces the power consumption. The work presented here is a purely industrial work, i.e. all experiments were performed directly on production tools at Sensitec GmbH in Mainz. In contrast to university research the focus was shifted to reproducibility and wafer uniformity instead of creating single perfect samples. In this thesis a TMR layer stack consisting of sputtered CoFeB electrodes, one of them being exchange-coupled with IrMn, and an ion beam deposited MgO barrier is presented. This system was studied by many research groups and is now transferred to an industrial environment. In contrast to most publications, the MgO barrier is being prepared by ion beam deposition, a novel preparation method for TMR stacks. Additionally Co2MnSi films for the use as potential electrodes were prepared by ion beam deposition and characterized structurally and magnetically.","abstract_has_math":false,"creators":["Gerken, Anna"],"institution":"Universität Bielefeld","degree_name":null,"degree_level":"thesis.doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-27T02:22:32Z","subjects":[],"languages":["eng"],"rights":["free"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Gerken A. <em>Realization of TMR devices in an industrial environment</em>. Bielefeld (Germany): Bielefeld University; 2010."],"render_values":[{"text":"Gerken A. <em>Realization of TMR devices in an industrial environment</em>. Bielefeld (Germany): Bielefeld University; 2010.","href":null,"code":true}]},{"key":"dc:publisher.identifier","label":"Dc Publisher Identifier","values":["24060-6"],"render_values":[{"text":"24060-6","href":null,"code":true}]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["24060-6"],"render_values":[{"text":"24060-6","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://nbn-resolving.org/urn:nbn:de:hbz:361-17946","outbound_label":"Persistent identifier","outbound_source":"dc:identifier.urn","record_url":"https://nbn-resolving.org/urn:nbn:de:hbz:361-17946","record_label":"Repository record","record_kind":"pid","record_source":"dc:identifier.urn","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abielefeld%3Aoai%3Apub.uni-bielefeld.de%3A2306435","prefix":"oai_dc"},"source_record":{"url":"https://pub.uni-bielefeld.de/oai?verb=GetRecord&metadataPrefix=xMetaDissPlus&identifier=oai%3Apub.uni-bielefeld.de%3A2306435","prefix":"xMetaDissPlus"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Gerken, Anna"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.dateaccepted","label":"Dc Date Dateaccepted","values":["2010-12-15"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Universitätsbibliothek Bielefeld"]},{"key":"dc:publisher.address","label":"Dc Publisher Address","values":["Universitätsstr. 25, 33615 Bielefeld"]},{"key":"dc:publisher.country","label":"Dc Publisher Country","values":["DE"]},{"key":"dc:publisher.identifier","label":"Dc Publisher Identifier","values":["24060-6"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Bielefeld"]},{"key":"dc:type","label":"Dc Type","values":["doctoralThesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"dc:type.version","label":"Dc Type Version","values":["publishedVersion"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis.doctoral"]},{"key":"thesis:institution_country","label":"Thesis Institution Country","values":["DE"]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["24060-6"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Universität Bielefeld"]},{"key":"thesis:institution_place","label":"Thesis Institution Place","values":["Bielefeld"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.ddc","label":"Dc Subject Ddc","values":["530"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]},{"key":"dc:rights.accessrights","label":"Access Rights","values":["free"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Gerken A. <em>Realization of TMR devices in an industrial environment</em>. Bielefeld (Germany): Bielefeld University; 2010."]},{"key":"dc:identifier.fulltext","label":"Full Text Identifier","values":["https://pub.uni-bielefeld.de/record/2306435"]},{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:hbz:361-17946"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Magnetoresistive sensors are widely used in sensor applications for magnetic field measurements. Currently these sensors mostly use the Anisotropic Magnetoresistive Effect (AMR) or the Giant Magnetoresistive Effect (GMR). Due to their unique properties sensors based on the TMR effect could be advantageous: They offer a higher MR-ratio, smaller lateral dimensions and a higher resistance which reduces the power consumption. The work presented here is a purely industrial work, i.e. all experiments were performed directly on production tools at Sensitec GmbH in Mainz. In contrast to university research the focus was shifted to reproducibility and wafer uniformity instead of creating single perfect samples. In this thesis a TMR layer stack consisting of sputtered CoFeB electrodes, one of them being exchange-coupled with IrMn, and an ion beam deposited MgO barrier is presented. This system was studied by many research groups and is now transferred to an industrial environment. In contrast to most publications, the MgO barrier is being prepared by ion beam deposition, a novel preparation method for TMR stacks. Additionally Co2MnSi films for the use as potential electrodes were prepared by ion beam deposition and characterized structurally and magnetically."]},{"key":"dc:format.fileid","label":"Dc Format Fileid","values":["2306438"]},{"key":"dc:format.filename","label":"Dc Format Filename","values":["Realization_of_TMR_Devices_in_an_Industrial_Environment.pdf"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Realization of TMR devices in an industrial environment"]},{"key":"ddb:contactid","label":"Ddb Contactid","values":["L6000-0538"]},{"key":"ddb:filenumber","label":"Ddb Filenumber","values":["1"]},{"key":"ddb:fileproperties","label":"Ddb Fileproperties","values":["aus: Praesentationsformat"]}]}],"canonical_facts":{"dc:creator":["Gerken, Anna"],"dc:date.dateaccepted":["2010-12-15"],"dc:date.issued":["2010"],"dc:description.abstract":["Magnetoresistive sensors are widely used in sensor applications for magnetic field measurements. Currently these sensors mostly use the Anisotropic Magnetoresistive Effect (AMR) or the Giant Magnetoresistive Effect (GMR). Due to their unique properties sensors based on the TMR effect could be advantageous: They offer a higher MR-ratio, smaller lateral dimensions and a higher resistance which reduces the power consumption. The work presented here is a purely industrial work, i.e. all experiments were performed directly on production tools at Sensitec GmbH in Mainz. In contrast to university research the focus was shifted to reproducibility and wafer uniformity instead of creating single perfect samples. In this thesis a TMR layer stack consisting of sputtered CoFeB electrodes, one of them being exchange-coupled with IrMn, and an ion beam deposited MgO barrier is presented. This system was studied by many research groups and is now transferred to an industrial environment. In contrast to most publications, the MgO barrier is being prepared by ion beam deposition, a novel preparation method for TMR stacks. Additionally Co2MnSi films for the use as potential electrodes were prepared by ion beam deposition and characterized structurally and magnetically."],"dc:format.fileid":["2306438"],"dc:format.filename":["Realization_of_TMR_Devices_in_an_Industrial_Environment.pdf"],"dc:format.medium":["application/pdf"],"dc:identifier.citation":["Gerken A. <em>Realization of TMR devices in an industrial environment</em>. Bielefeld (Germany): Bielefeld University; 2010."],"dc:identifier.fulltext":["https://pub.uni-bielefeld.de/record/2306435"],"dc:identifier.urn":["urn:nbn:de:hbz:361-17946"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher":["Universitätsbibliothek Bielefeld"],"dc:publisher.address":["Universitätsstr. 25, 33615 Bielefeld"],"dc:publisher.country":["DE"],"dc:publisher.identifier":["24060-6"],"dc:publisher.place":["Bielefeld"],"dc:rights.accessrights":["free"],"dc:subject.ddc":["530"],"dc:title":["Realization of TMR devices in an industrial environment"],"dc:type":["doctoralThesis"],"dc:type.dcmitype":["Text"],"dc:type.version":["publishedVersion"],"ddb:contactid":["L6000-0538"],"ddb:filenumber":["1"],"ddb:fileproperties":["aus: Praesentationsformat"],"thesis:degree_level":["thesis.doctoral"],"thesis:institution_country":["DE"],"thesis:institution_identifier":["24060-6"],"thesis:institution_name":["Universität Bielefeld"],"thesis:institution_place":["Bielefeld"]},"updated_at":"2026-11-27T02:22:32Z"}