{"id":{"repo_id":"bielefeld","oai_identifier":"oai:pub.uni-bielefeld.de:3016397"},"canonical_url":"https://search.ndltd.org/etd/bielefeld/oai:pub.uni-bielefeld.de:3016397","repository":{"repo_id":"bielefeld","name":"Universität Bielefeld","base_url":"https://pub.uni-bielefeld.de/oai"},"display":{"title":"Advancements In Biosignal Analysis For Models of Musculotendon Actuators. Ultrasound B-Mode Imaging for Tendon Stiffness Estimation and sEMG Forward Modelling for In Vivo Innervation Zone Tracking","abstract":"This work presents three key contributions to the analysis of biosignals recorded from the musculotendon actuator of the human arm. It focuses specifically on surface electromyography (sEMG) signals and ultrasonic measurements of the myotendinous junction. The overarching objective is to advance prediction models of human limb movements. These models enable improved control of actuated exoskeletons. The first contribution is a new method for the measurement of tendon properties *in vivo*. A protocol for the recording of ultrasonic B-mode videos of the distal *biceps brachii* tendon under varying load conditions and elbow angles is presented. Based on these data, a new (semi-)automatic method for the extraction of the tendon displacement during muscle contraction is presented. Finally, parameters of a non-linear force-strain tendon model are optimised using the extracted data. The second contribution consists of a computationally efficient, electric field sEMG computer model which represents complete muscles consisting of hundreds of thousands of muscle fibres. A wide range of muscle configurations can be simulated with relatively short computation times. This efficient computation time is achieved by abstracting the non-linear current sources of each muscle fibre with a set of six concentrated current sources. This sEMG model is used to evaluate a new algorithm for the estimation of innervation zones based on sEMG signals measured with electrode arrays. The third contribution addresses the estimation of the muscle innervation zone (IZ). The IZ is a key characteristic of muscle physiology that relates to the origin of sEMG signals. This new method achieves an accuracy of below 1&thinsp;mm, and could be used to estimate muscle length.","abstract_html":"This work presents three key contributions to the analysis of biosignals recorded from the musculotendon actuator of the human arm. It focuses specifically on surface electromyography (sEMG) signals and ultrasonic measurements of the myotendinous junction. The overarching objective is to advance prediction models of human limb movements. These models enable improved control of actuated exoskeletons. The first contribution is a new method for the measurement of tendon properties *in vivo*. A protocol for the recording of ultrasonic B-mode videos of the distal *biceps brachii* tendon under varying load conditions and elbow angles is presented. Based on these data, a new (semi-)automatic method for the extraction of the tendon displacement during muscle contraction is presented. Finally, parameters of a non-linear force-strain tendon model are optimised using the extracted data. The second contribution consists of a computationally efficient, electric field sEMG computer model which represents complete muscles consisting of hundreds of thousands of muscle fibres. A wide range of muscle configurations can be simulated with relatively short computation times. This efficient computation time is achieved by abstracting the non-linear current sources of each muscle fibre with a set of six concentrated current sources. This sEMG model is used to evaluate a new algorithm for the estimation of innervation zones based on sEMG signals measured with electrode arrays. The third contribution addresses the estimation of the muscle innervation zone (IZ). The IZ is a key characteristic of muscle physiology that relates to the origin of sEMG signals. This new method achieves an accuracy of below 1&amp;thinsp;mm, and could be used to estimate muscle length.","abstract_has_math":false,"creators":["Mechtenberg, Malte"],"institution":"Universität Bielefeld","degree_name":null,"degree_level":"thesis.doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-26T13:49:35Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:0070-pub-30163978"],"render_values":[{"text":"urn:nbn:de:0070-pub-30163978","href":"https://nbn-resolving.org/urn:nbn:de:0070-pub-30163978","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Mechtenberg M. <em>Advancements In Biosignal Analysis For Models of Musculotendon Actuators. Ultrasound B-Mode Imaging for Tendon Stiffness Estimation and sEMG Forward Modelling for In Vivo Innervation Zone Tracking</em>. Bielefeld: Universität Bielefeld; 2026."],"render_values":[{"text":"Mechtenberg M. <em>Advancements In Biosignal Analysis For Models of Musculotendon Actuators. Ultrasound B-Mode Imaging for Tendon Stiffness Estimation and sEMG Forward Modelling for In Vivo Innervation Zone Tracking</em>. Bielefeld: Universität Bielefeld; 2026.","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.4119/unibi/3016397","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.4119/unibi/3016397","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abielefeld%3Aoai%3Apub.uni-bielefeld.de%3A3016397","prefix":"oai_dc"},"source_record":{"url":"https://pub.uni-bielefeld.de/oai?verb=GetRecord&metadataPrefix=xMetaDissPlus&identifier=oai%3Apub.uni-bielefeld.de%3A3016397","prefix":"xMetaDissPlus"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mechtenberg, Malte"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.dateaccepted","label":"Dc Date Dateaccepted","values":["2025-12-04"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Universitätsbibliothek Bielefeld"]},{"key":"dc:type","label":"Dc Type","values":["doctoralThesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"dc:type.version","label":"Dc Type Version","values":["publishedVersion"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis.doctoral"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Universität Bielefeld"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.ddc","label":"Dc Subject Ddc","values":["600"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Mechtenberg M. <em>Advancements In Biosignal Analysis For Models of Musculotendon Actuators. Ultrasound B-Mode Imaging for Tendon Stiffness Estimation and sEMG Forward Modelling for In Vivo Innervation Zone Tracking</em>. Bielefeld: Universität Bielefeld; 2026."]},{"key":"dc:identifier.doi","label":"DOI","values":["10.4119/unibi/3016397"]},{"key":"dc:identifier.fulltext","label":"Full Text Identifier","values":["https://pub.uni-bielefeld.de/record/3016397"]},{"key":"dc:identifier.urn","label":"URN","values":["urn:nbn:de:0070-pub-30163978"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work presents three key contributions to the analysis of biosignals recorded from the musculotendon actuator of the human arm. It focuses specifically on surface electromyography (sEMG) signals and ultrasonic measurements of the myotendinous junction. The overarching objective is to advance prediction models of human limb movements. These models enable improved control of actuated exoskeletons. The first contribution is a new method for the measurement of tendon properties *in vivo*. A protocol for the recording of ultrasonic B-mode videos of the distal *biceps brachii* tendon under varying load conditions and elbow angles is presented. Based on these data, a new (semi-)automatic method for the extraction of the tendon displacement during muscle contraction is presented. Finally, parameters of a non-linear force-strain tendon model are optimised using the extracted data. The second contribution consists of a computationally efficient, electric field sEMG computer model which represents complete muscles consisting of hundreds of thousands of muscle fibres. A wide range of muscle configurations can be simulated with relatively short computation times. This efficient computation time is achieved by abstracting the non-linear current sources of each muscle fibre with a set of six concentrated current sources. This sEMG model is used to evaluate a new algorithm for the estimation of innervation zones based on sEMG signals measured with electrode arrays. The third contribution addresses the estimation of the muscle innervation zone (IZ). The IZ is a key characteristic of muscle physiology that relates to the origin of sEMG signals. This new method achieves an accuracy of below 1&thinsp;mm, and could be used to estimate muscle length."]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Advancements In Biosignal Analysis For Models of Musculotendon Actuators. Ultrasound B-Mode Imaging for Tendon Stiffness Estimation and sEMG Forward Modelling for In Vivo Innervation Zone Tracking"]},{"key":"ddb:filenumber","label":"Ddb Filenumber","values":["1"]},{"key":"ddb:fileproperties","label":"Ddb Fileproperties","values":["aus: Praesentationsformat"]}]}],"canonical_facts":{"dc:creator":["Mechtenberg, Malte"],"dc:date.dateaccepted":["2025-12-04"],"dc:date.issued":["2026"],"dc:description.abstract":["This work presents three key contributions to the analysis of biosignals recorded from the musculotendon actuator of the human arm. It focuses specifically on surface electromyography (sEMG) signals and ultrasonic measurements of the myotendinous junction. The overarching objective is to advance prediction models of human limb movements. These models enable improved control of actuated exoskeletons. The first contribution is a new method for the measurement of tendon properties *in vivo*. A protocol for the recording of ultrasonic B-mode videos of the distal *biceps brachii* tendon under varying load conditions and elbow angles is presented. Based on these data, a new (semi-)automatic method for the extraction of the tendon displacement during muscle contraction is presented. Finally, parameters of a non-linear force-strain tendon model are optimised using the extracted data. The second contribution consists of a computationally efficient, electric field sEMG computer model which represents complete muscles consisting of hundreds of thousands of muscle fibres. A wide range of muscle configurations can be simulated with relatively short computation times. This efficient computation time is achieved by abstracting the non-linear current sources of each muscle fibre with a set of six concentrated current sources. This sEMG model is used to evaluate a new algorithm for the estimation of innervation zones based on sEMG signals measured with electrode arrays. The third contribution addresses the estimation of the muscle innervation zone (IZ). The IZ is a key characteristic of muscle physiology that relates to the origin of sEMG signals. This new method achieves an accuracy of below 1&thinsp;mm, and could be used to estimate muscle length."],"dc:format.medium":["application/pdf"],"dc:identifier.citation":["Mechtenberg M. <em>Advancements In Biosignal Analysis For Models of Musculotendon Actuators. Ultrasound B-Mode Imaging for Tendon Stiffness Estimation and sEMG Forward Modelling for In Vivo Innervation Zone Tracking</em>. Bielefeld: Universität Bielefeld; 2026."],"dc:identifier.doi":["10.4119/unibi/3016397"],"dc:identifier.fulltext":["https://pub.uni-bielefeld.de/record/3016397"],"dc:identifier.urn":["urn:nbn:de:0070-pub-30163978"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher":["Universitätsbibliothek Bielefeld"],"dc:subject.ddc":["600"],"dc:title":["Advancements In Biosignal Analysis For Models of Musculotendon Actuators. Ultrasound B-Mode Imaging for Tendon Stiffness Estimation and sEMG Forward Modelling for In Vivo Innervation Zone Tracking"],"dc:type":["doctoralThesis"],"dc:type.dcmitype":["Text"],"dc:type.version":["publishedVersion"],"ddb:filenumber":["1"],"ddb:fileproperties":["aus: Praesentationsformat"],"thesis:degree_level":["thesis.doctoral"],"thesis:institution_name":["Universität Bielefeld"]},"updated_at":"2026-11-26T13:49:35Z"}