{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:10022"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:10022","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Early failure detection of insulated-gate bipolar transistor semiconductor devices for the power converters of wind turbines","abstract":"There has been a remarkable increase in the use of wind power generation over the past ten years. However, costly unplanned downtimes caused by reliability issues are a problem. The most common power semiconductor failure mechanisms are bond wire lift off and solder fatigue. Failure detectors should ideally be sensitive enough to detect the early signs of failure and the progress of failure, as well as being applicable during normal operation of a three-phase converter. The junction temperature of an IGBT module has been widely used as a potential failure detector. However, restricting monitoring to purely junction temperature is highly likely to lead to false alarms as the temperature naturally changes with wind conditions. The research in this thesis explores new methods for monitoring the health of IGBTs in an operational wind turbine using a combination of thermal and electrical modelling and a lab-based three-phase converter. The main key findings to the existing knowledge are finding a new method of temperature detection, which is uncoupled with the common failure mechanisms (the bond wire lift-off and solder fatigue) in wind turbines, but also introduce a new temperature estimation method that is uncoupled with progress of the failure.","abstract_html":"There has been a remarkable increase in the use of wind power generation over the past ten years. However, costly unplanned downtimes caused by reliability issues are a problem. The most common power semiconductor failure mechanisms are bond wire lift off and solder fatigue. Failure detectors should ideally be sensitive enough to detect the early signs of failure and the progress of failure, as well as being applicable during normal operation of a three-phase converter. The junction temperature of an IGBT module has been widely used as a potential failure detector. However, restricting monitoring to purely junction temperature is highly likely to lead to false alarms as the temperature naturally changes with wind conditions. The research in this thesis explores new methods for monitoring the health of IGBTs in an operational wind turbine using a combination of thermal and electrical modelling and a lab-based three-phase converter. The main key findings to the existing knowledge are finding a new method of temperature detection, which is uncoupled with the common failure mechanisms (the bond wire lift-off and solder fatigue) in wind turbines, but also introduce a new temperature estimation method that is uncoupled with progress of the failure.","abstract_has_math":false,"creators":["Moeini, Rana"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-07","date_published":"2020-07","updated_at":"2026-11-19T09:30:56Z","subjects":["TA Engineering (General). Civil engineering (General)","TK Electrical engineering. Electronics Nuclear engineering","TS Manufactures"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/10022/8/Moeini2020PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A10022","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Moeini, Rana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-07"]},{"key":"dc:date.issued","label":"Date","values":["2020-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/10022/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TA Engineering (General). Civil engineering (General)","TK Electrical engineering. Electronics Nuclear engineering","TS Manufactures"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/10022/8/Moeini2020PhD.pdf","http://etheses.bham.ac.uk//id/eprint/10022/7/Moeini2020PhD_Erratum_Notice.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["There has been a remarkable increase in the use of wind power generation over the past ten years. However, costly unplanned downtimes caused by reliability issues are a problem. The most common power semiconductor failure mechanisms are bond wire lift off and solder fatigue. Failure detectors should ideally be sensitive enough to detect the early signs of failure and the progress of failure, as well as being applicable during normal operation of a three-phase converter. The junction temperature of an IGBT module has been widely used as a potential failure detector. However, restricting monitoring to purely junction temperature is highly likely to lead to false alarms as the temperature naturally changes with wind conditions. The research in this thesis explores new methods for monitoring the health of IGBTs in an operational wind turbine using a combination of thermal and electrical modelling and a lab-based three-phase converter. The main key findings to the existing knowledge are finding a new method of temperature detection, which is uncoupled with the common failure mechanisms (the bond wire lift-off and solder fatigue) in wind turbines, but also introduce a new temperature estimation method that is uncoupled with progress of the failure."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Early failure detection of insulated-gate bipolar transistor semiconductor devices for the power converters of wind turbines"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Moeini, Rana"],"dc:date":["2020-07"],"dc:date.issued":["2020-07"],"dc:description.abstract":["There has been a remarkable increase in the use of wind power generation over the past ten years. However, costly unplanned downtimes caused by reliability issues are a problem. The most common power semiconductor failure mechanisms are bond wire lift off and solder fatigue. Failure detectors should ideally be sensitive enough to detect the early signs of failure and the progress of failure, as well as being applicable during normal operation of a three-phase converter. The junction temperature of an IGBT module has been widely used as a potential failure detector. However, restricting monitoring to purely junction temperature is highly likely to lead to false alarms as the temperature naturally changes with wind conditions. The research in this thesis explores new methods for monitoring the health of IGBTs in an operational wind turbine using a combination of thermal and electrical modelling and a lab-based three-phase converter. The main key findings to the existing knowledge are finding a new method of temperature detection, which is uncoupled with the common failure mechanisms (the bond wire lift-off and solder fatigue) in wind turbines, but also introduce a new temperature estimation method that is uncoupled with progress of the failure."],"dc:format":["text"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/10022/8/Moeini2020PhD.pdf","http://etheses.bham.ac.uk//id/eprint/10022/7/Moeini2020PhD_Erratum_Notice.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/10022/"],"dc:subject":["TA Engineering (General). Civil engineering (General)","TK Electrical engineering. Electronics Nuclear engineering","TS Manufactures"],"dcterms:accessrights":["public"],"dc:title":["Early failure detection of insulated-gate bipolar transistor semiconductor devices for the power converters of wind turbines"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:30:56Z"}