{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:11057"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:11057","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Parasitic production of Cobalt-57 for quality control use","abstract":"Routine quality control is performed in all nuclear medicine departments and requires image uniformity measurements of gamma camera systems. Cobalt-57 (\\(^{57}\\)Co) flood sources are well suited to this task due the energy emissions of \\(^{57}\\)Co being similar to the main nuclear medicine radionuclide of Technetium-99m (\\(^{99m}\\)Tc). One method for producing \\(^{57}\\)Co is proton bombardment of nickel. An equally important isotope is Rubidium-81 (\\(^{81}\\)Rb) which decays to Krypton-81m (\\(^{81m}\\)Kr) and used in the diagnosis of pulmonary embolism. Rubidium-81 is produced by proton bombardment of enriched \\(^{82}\\)Kr gas contained in a nickel plated target. Presented in this work is a detailed investigation of cyclotron production conditions whereby both \\(^{81}\\)Rb and \\(^{57}\\)Co yields are at maximum and produced simultaneously. Production in this manner is seen by the author as novel and desirable as overall costs for producing both isotopes is reduced. A number of nuclear reactions were investigated theoretically which were then tested experimentally. A comprehensive review of known data bases gave published reaction data. These data were used to make predictions around target yield and more importantly contaminant isotope yields. A way to utilise the parasitically produced \\(^{57}\\)Co for production of radioactive quality control sources was also investigated. This showed the concept of thermal drop on demand printing of a flood source to give high uniformity required for flood source manufacture.","abstract_html":"Routine quality control is performed in all nuclear medicine departments and requires image uniformity measurements of gamma camera systems. Cobalt-57 (<span class=\"etd-inline-math\"><sup>57</sup></span>Co) flood sources are well suited to this task due the energy emissions of <span class=\"etd-inline-math\"><sup>57</sup></span>Co being similar to the main nuclear medicine radionuclide of Technetium-99m (<span class=\"etd-inline-math\"><sup>99m</sup></span>Tc). One method for producing <span class=\"etd-inline-math\"><sup>57</sup></span>Co is proton bombardment of nickel. An equally important isotope is Rubidium-81 (<span class=\"etd-inline-math\"><sup>81</sup></span>Rb) which decays to Krypton-81m (<span class=\"etd-inline-math\"><sup>81m</sup></span>Kr) and used in the diagnosis of pulmonary embolism. Rubidium-81 is produced by proton bombardment of enriched <span class=\"etd-inline-math\"><sup>82</sup></span>Kr gas contained in a nickel plated target. Presented in this work is a detailed investigation of cyclotron production conditions whereby both <span class=\"etd-inline-math\"><sup>81</sup></span>Rb and <span class=\"etd-inline-math\"><sup>57</sup></span>Co yields are at maximum and produced simultaneously. Production in this manner is seen by the author as novel and desirable as overall costs for producing both isotopes is reduced. A number of nuclear reactions were investigated theoretically which were then tested experimentally. A comprehensive review of known data bases gave published reaction data. These data were used to make predictions around target yield and more importantly contaminant isotope yields. A way to utilise the parasitically produced <span class=\"etd-inline-math\"><sup>57</sup></span>Co for production of radioactive quality control sources was also investigated. This showed the concept of thermal drop on demand printing of a flood source to give high uniformity required for flood source manufacture.","abstract_has_math":true,"creators":["Neale, Alexander James"],"institution":"University of Birmingham","degree_name":"m_sc","degree_level":"m_sc","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-11","date_published":"2020-11","updated_at":"2026-11-19T09:31:15Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/11057/1/Neale2020MSc.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A11057","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Neale, Alexander James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-11-25"]},{"key":"dc:date.issued","label":"Date","values":["2020-11"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Physics and Astronomy"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/11057/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["m_sc"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["m_sc"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/11057/1/Neale2020MSc.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Routine quality control is performed in all nuclear medicine departments and requires image uniformity measurements of gamma camera systems. Cobalt-57 (\\(^{57}\\)Co) flood sources are well suited to this task due the energy emissions of \\(^{57}\\)Co being similar to the main nuclear medicine radionuclide of Technetium-99m (\\(^{99m}\\)Tc). One method for producing \\(^{57}\\)Co is proton bombardment of nickel. An equally important isotope is Rubidium-81 (\\(^{81}\\)Rb) which decays to Krypton-81m (\\(^{81m}\\)Kr) and used in the diagnosis of pulmonary embolism. Rubidium-81 is produced by proton bombardment of enriched \\(^{82}\\)Kr gas contained in a nickel plated target. Presented in this work is a detailed investigation of cyclotron production conditions whereby both \\(^{81}\\)Rb and \\(^{57}\\)Co yields are at maximum and produced simultaneously. Production in this manner is seen by the author as novel and desirable as overall costs for producing both isotopes is reduced. A number of nuclear reactions were investigated theoretically which were then tested experimentally. A comprehensive review of known data bases gave published reaction data. These data were used to make predictions around target yield and more importantly contaminant isotope yields. A way to utilise the parasitically produced \\(^{57}\\)Co for production of radioactive quality control sources was also investigated. This showed the concept of thermal drop on demand printing of a flood source to give high uniformity required for flood source manufacture."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Parasitic production of Cobalt-57 for quality control use"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Neale, Alexander James"],"dc:date":["2020-11-25"],"dc:date.issued":["2020-11"],"dc:description.abstract":["Routine quality control is performed in all nuclear medicine departments and requires image uniformity measurements of gamma camera systems. Cobalt-57 (\\(^{57}\\)Co) flood sources are well suited to this task due the energy emissions of \\(^{57}\\)Co being similar to the main nuclear medicine radionuclide of Technetium-99m (\\(^{99m}\\)Tc). One method for producing \\(^{57}\\)Co is proton bombardment of nickel. An equally important isotope is Rubidium-81 (\\(^{81}\\)Rb) which decays to Krypton-81m (\\(^{81m}\\)Kr) and used in the diagnosis of pulmonary embolism. Rubidium-81 is produced by proton bombardment of enriched \\(^{82}\\)Kr gas contained in a nickel plated target. Presented in this work is a detailed investigation of cyclotron production conditions whereby both \\(^{81}\\)Rb and \\(^{57}\\)Co yields are at maximum and produced simultaneously. Production in this manner is seen by the author as novel and desirable as overall costs for producing both isotopes is reduced. A number of nuclear reactions were investigated theoretically which were then tested experimentally. A comprehensive review of known data bases gave published reaction data. These data were used to make predictions around target yield and more importantly contaminant isotope yields. A way to utilise the parasitically produced \\(^{57}\\)Co for production of radioactive quality control sources was also investigated. This showed the concept of thermal drop on demand printing of a flood source to give high uniformity required for flood source manufacture."],"dc:format":["text"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/11057/1/Neale2020MSc.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Physics and Astronomy"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/11057/"],"dcterms:accessrights":["public"],"dc:title":["Parasitic production of Cobalt-57 for quality control use"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["m_sc"],"dc:type.qualificationname":["m_sc"]},"updated_at":"2026-11-19T09:31:15Z"}