{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:11079"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:11079","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"A study of the suitability of pre-mixed self-etching primers as orthodontic bonding agents","abstract":"Aims This study aimed to examine the suitability of single-component self-etching primers (1 SEP) as orthodontic bonding agents. A further aim of the investigation was to establish whether 1-SEP could be used successfully to bond brackets when the pre-cure step in the bonding protocol of 1-SEP was omitted. Method Four hundred and twenty human premolars were cleaned, mounted and divided into seven groups by random allocation. Pre-coated stainless-steel brackets were used. The seven protocols were: Groups 1-3: Pre-cure (PC) protocol: Xeno V+, Clearfil S3 and iBond SE were applied to enamel, light cured, brackets placed and light cured again; Groups 4-7: Co-cure (CC) protocol: the same 1-SEPs as the Pre-cure group were used, however, the light curing step prior to bracket placement was omitted. A multi-step SEP, Transbond Plus, was used as a co-cured control (group 7). Bonded specimens were subject to three experimental conditions: debonding within 30 minutes from initial bonding, thermocycling between 5 ºC and 55 ºC for 500 cycles and water storage at 37 ºC for 7 days. The teeth were debonded using a Universal Testing Machine. The amount of residual adhesive on the tooth surface was determined by visual examination under x 10 magnification. Results Mean shear bond strengths (SBS) of brackets bonded with Xeno V+, Clearfil S3 and iBond SE were 7.86 +/- 2.27 MPa, 5.71 +/- 2.43 MPa and 6.24 +/- 1.96 MPa respectively when debonded within 30 minutes. After thermocycling (Xeno V+ 2.11 +/- 1.73 MPa; Clearfil S3 4.36 +/- 3.31 MPa; iBond SE 0.66 +/- 0.62 MPa) and water storage (Xeno V+ 3.10 +/- 3.08 MPa; Clearfil S3 5.16 +/- 3.43 MPa; iBond SE 4.48 +/- 1.85 MPa) the mean SBS of 1-SEP were below acceptable clinical levels. Co-curing improved bond strengths for aged specimens in all cases. Highest bond strengths were recorded for co-cured Xeno V+ (13.09 +/- 4.01 MPa) and Clearfil S3 (13.07 +/- 4.03 MPa) after water storage which were not significantly different to the control (12.68 +/- 4.74 MPa) (P<.05). Predominant failure mode for 1-SEP was at the enamel-adhesive interface, however Clearfil S3 that was co-cured left significantly more adhesive on enamel compared to adhesive that was pre-cured (P=.006). Conclusion Early shear bond strengths of 1-SEP within 30 minutes may be clinically acceptable. However, after ageing with thermocycling or water storage, bond strengths were unsatisfactory. Co-curing improved bond strengths, elevating the performance of Xeno V+ and Clearfil S3 after ageing, to clinically acceptable levels which may occur due to enhanced interaction between 1-SEP and enamel. Most of the adhesive remained on the bracket, although Clearfil S3 left more adhesive on the tooth surface when co-cured.","abstract_html":"Aims This study aimed to examine the suitability of single-component self-etching primers (1 SEP) as orthodontic bonding agents. A further aim of the investigation was to establish whether 1-SEP could be used successfully to bond brackets when the pre-cure step in the bonding protocol of 1-SEP was omitted. Method Four hundred and twenty human premolars were cleaned, mounted and divided into seven groups by random allocation. Pre-coated stainless-steel brackets were used. The seven protocols were: Groups 1-3: Pre-cure (PC) protocol: Xeno V+, Clearfil S3 and iBond SE were applied to enamel, light cured, brackets placed and light cured again; Groups 4-7: Co-cure (CC) protocol: the same 1-SEPs as the Pre-cure group were used, however, the light curing step prior to bracket placement was omitted. A multi-step SEP, Transbond Plus, was used as a co-cured control (group 7). Bonded specimens were subject to three experimental conditions: debonding within 30 minutes from initial bonding, thermocycling between 5 ºC and 55 ºC for 500 cycles and water storage at 37 ºC for 7 days. The teeth were debonded using a Universal Testing Machine. The amount of residual adhesive on the tooth surface was determined by visual examination under x 10 magnification. Results Mean shear bond strengths (SBS) of brackets bonded with Xeno V+, Clearfil S3 and iBond SE were 7.86 +/- 2.27 MPa, 5.71 +/- 2.43 MPa and 6.24 +/- 1.96 MPa respectively when debonded within 30 minutes. After thermocycling (Xeno V+ 2.11 +/- 1.73 MPa; Clearfil S3 4.36 +/- 3.31 MPa; iBond SE 0.66 +/- 0.62 MPa) and water storage (Xeno V+ 3.10 +/- 3.08 MPa; Clearfil S3 5.16 +/- 3.43 MPa; iBond SE 4.48 +/- 1.85 MPa) the mean SBS of 1-SEP were below acceptable clinical levels. Co-curing improved bond strengths for aged specimens in all cases. Highest bond strengths were recorded for co-cured Xeno V+ (13.09 +/- 4.01 MPa) and Clearfil S3 (13.07 +/- 4.03 MPa) after water storage which were not significantly different to the control (12.68 +/- 4.74 MPa) (P&lt;.05). Predominant failure mode for 1-SEP was at the enamel-adhesive interface, however Clearfil S3 that was co-cured left significantly more adhesive on enamel compared to adhesive that was pre-cured (P=.006). Conclusion Early shear bond strengths of 1-SEP within 30 minutes may be clinically acceptable. However, after ageing with thermocycling or water storage, bond strengths were unsatisfactory. Co-curing improved bond strengths, elevating the performance of Xeno V+ and Clearfil S3 after ageing, to clinically acceptable levels which may occur due to enhanced interaction between 1-SEP and enamel. Most of the adhesive remained on the bracket, although Clearfil S3 left more adhesive on the tooth surface when co-cured.","abstract_has_math":false,"creators":["Adams, Lorna"],"institution":"University of Birmingham","degree_name":"m_ph","degree_level":"m_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-11","date_published":"2020-11","updated_at":"2026-11-19T09:31:19Z","subjects":["RK Dentistry"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/11079/7/Adams2020MPhil_Redacted.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A11079","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Adams, Lorna"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-11-25"]},{"key":"dc:date.issued","label":"Date","values":["2020-11"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Medical & Dental Sciences","School of Dentistry"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/11079/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["m_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["m_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["RK Dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/11079/7/Adams2020MPhil_Redacted.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Aims This study aimed to examine the suitability of single-component self-etching primers (1 SEP) as orthodontic bonding agents. A further aim of the investigation was to establish whether 1-SEP could be used successfully to bond brackets when the pre-cure step in the bonding protocol of 1-SEP was omitted. Method Four hundred and twenty human premolars were cleaned, mounted and divided into seven groups by random allocation. Pre-coated stainless-steel brackets were used. The seven protocols were: Groups 1-3: Pre-cure (PC) protocol: Xeno V+, Clearfil S3 and iBond SE were applied to enamel, light cured, brackets placed and light cured again; Groups 4-7: Co-cure (CC) protocol: the same 1-SEPs as the Pre-cure group were used, however, the light curing step prior to bracket placement was omitted. A multi-step SEP, Transbond Plus, was used as a co-cured control (group 7). Bonded specimens were subject to three experimental conditions: debonding within 30 minutes from initial bonding, thermocycling between 5 ºC and 55 ºC for 500 cycles and water storage at 37 ºC for 7 days. The teeth were debonded using a Universal Testing Machine. The amount of residual adhesive on the tooth surface was determined by visual examination under x 10 magnification. Results Mean shear bond strengths (SBS) of brackets bonded with Xeno V+, Clearfil S3 and iBond SE were 7.86 +/- 2.27 MPa, 5.71 +/- 2.43 MPa and 6.24 +/- 1.96 MPa respectively when debonded within 30 minutes. After thermocycling (Xeno V+ 2.11 +/- 1.73 MPa; Clearfil S3 4.36 +/- 3.31 MPa; iBond SE 0.66 +/- 0.62 MPa) and water storage (Xeno V+ 3.10 +/- 3.08 MPa; Clearfil S3 5.16 +/- 3.43 MPa; iBond SE 4.48 +/- 1.85 MPa) the mean SBS of 1-SEP were below acceptable clinical levels. Co-curing improved bond strengths for aged specimens in all cases. Highest bond strengths were recorded for co-cured Xeno V+ (13.09 +/- 4.01 MPa) and Clearfil S3 (13.07 +/- 4.03 MPa) after water storage which were not significantly different to the control (12.68 +/- 4.74 MPa) (P<.05). Predominant failure mode for 1-SEP was at the enamel-adhesive interface, however Clearfil S3 that was co-cured left significantly more adhesive on enamel compared to adhesive that was pre-cured (P=.006). Conclusion Early shear bond strengths of 1-SEP within 30 minutes may be clinically acceptable. However, after ageing with thermocycling or water storage, bond strengths were unsatisfactory. Co-curing improved bond strengths, elevating the performance of Xeno V+ and Clearfil S3 after ageing, to clinically acceptable levels which may occur due to enhanced interaction between 1-SEP and enamel. Most of the adhesive remained on the bracket, although Clearfil S3 left more adhesive on the tooth surface when co-cured."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["A study of the suitability of pre-mixed self-etching primers as orthodontic bonding agents"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Adams, Lorna"],"dc:date":["2020-11-25"],"dc:date.issued":["2020-11"],"dc:description.abstract":["Aims This study aimed to examine the suitability of single-component self-etching primers (1 SEP) as orthodontic bonding agents. A further aim of the investigation was to establish whether 1-SEP could be used successfully to bond brackets when the pre-cure step in the bonding protocol of 1-SEP was omitted. Method Four hundred and twenty human premolars were cleaned, mounted and divided into seven groups by random allocation. Pre-coated stainless-steel brackets were used. The seven protocols were: Groups 1-3: Pre-cure (PC) protocol: Xeno V+, Clearfil S3 and iBond SE were applied to enamel, light cured, brackets placed and light cured again; Groups 4-7: Co-cure (CC) protocol: the same 1-SEPs as the Pre-cure group were used, however, the light curing step prior to bracket placement was omitted. A multi-step SEP, Transbond Plus, was used as a co-cured control (group 7). Bonded specimens were subject to three experimental conditions: debonding within 30 minutes from initial bonding, thermocycling between 5 ºC and 55 ºC for 500 cycles and water storage at 37 ºC for 7 days. The teeth were debonded using a Universal Testing Machine. The amount of residual adhesive on the tooth surface was determined by visual examination under x 10 magnification. Results Mean shear bond strengths (SBS) of brackets bonded with Xeno V+, Clearfil S3 and iBond SE were 7.86 +/- 2.27 MPa, 5.71 +/- 2.43 MPa and 6.24 +/- 1.96 MPa respectively when debonded within 30 minutes. After thermocycling (Xeno V+ 2.11 +/- 1.73 MPa; Clearfil S3 4.36 +/- 3.31 MPa; iBond SE 0.66 +/- 0.62 MPa) and water storage (Xeno V+ 3.10 +/- 3.08 MPa; Clearfil S3 5.16 +/- 3.43 MPa; iBond SE 4.48 +/- 1.85 MPa) the mean SBS of 1-SEP were below acceptable clinical levels. Co-curing improved bond strengths for aged specimens in all cases. Highest bond strengths were recorded for co-cured Xeno V+ (13.09 +/- 4.01 MPa) and Clearfil S3 (13.07 +/- 4.03 MPa) after water storage which were not significantly different to the control (12.68 +/- 4.74 MPa) (P<.05). Predominant failure mode for 1-SEP was at the enamel-adhesive interface, however Clearfil S3 that was co-cured left significantly more adhesive on enamel compared to adhesive that was pre-cured (P=.006). Conclusion Early shear bond strengths of 1-SEP within 30 minutes may be clinically acceptable. However, after ageing with thermocycling or water storage, bond strengths were unsatisfactory. Co-curing improved bond strengths, elevating the performance of Xeno V+ and Clearfil S3 after ageing, to clinically acceptable levels which may occur due to enhanced interaction between 1-SEP and enamel. Most of the adhesive remained on the bracket, although Clearfil S3 left more adhesive on the tooth surface when co-cured."],"dc:format":["text"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/11079/7/Adams2020MPhil_Redacted.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Medical & Dental Sciences","School of Dentistry"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/11079/"],"dc:subject":["RK Dentistry"],"dcterms:accessrights":["public"],"dc:title":["A study of the suitability of pre-mixed self-etching primers as orthodontic bonding agents"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["m_ph"],"dc:type.qualificationname":["m_ph"]},"updated_at":"2026-11-19T09:31:19Z"}