{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:11353"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:11353","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Point of care diagnostics for traumatic brain injury","abstract":"Traumatic brain injury (TBI) is a major burden on healthcare services worldwide, which currently lacks an effective method for point-­of­-care (PoC) diagnostics and monitoring. In this thesis, the prospect of using Raman spectroscopy, as a non­invasive means to mea­sure chemical changes indicative of TBI from the back of the eye is explored. Through the development of multivariate analysis methods, self­ organising maps are highlighted as a superior alternative to principal component analysis and are successfully used to in­troduce a new means of classification. A classification accuracy of > 93 % is demonstrated over five tissue types applied to anatomical layers of ocular porcine eyes. Subsequently, in a clinically relevant murine model of TBI, an ability to accurately identify TBI and in­jury severity from Raman spectra of the retina is demonstrated for the first time. Using feature extraction, intrinsically linked to the classification result, the findings are associ­ated with a decrease in cardiolipin linked to metabolic distress, which is a hallmark of TBI. Finally, in an effort to translate the technology, a (patent pending) handheld system has been developed. Simultaneously, fundus photography is combined with eye safe Raman spectroscopy, measuring high wavenumber bands from a three­dimensional printed tissue phantom of the undilated human eye.","abstract_html":"Traumatic brain injury (TBI) is a major burden on healthcare services worldwide, which currently lacks an effective method for point-­of­-care (PoC) diagnostics and monitoring. In this thesis, the prospect of using Raman spectroscopy, as a non­invasive means to mea­sure chemical changes indicative of TBI from the back of the eye is explored. Through the development of multivariate analysis methods, self­ organising maps are highlighted as a superior alternative to principal component analysis and are successfully used to in­troduce a new means of classification. A classification accuracy of &gt; 93 % is demonstrated over five tissue types applied to anatomical layers of ocular porcine eyes. Subsequently, in a clinically relevant murine model of TBI, an ability to accurately identify TBI and in­jury severity from Raman spectra of the retina is demonstrated for the first time. Using feature extraction, intrinsically linked to the classification result, the findings are associ­ated with a decrease in cardiolipin linked to metabolic distress, which is a hallmark of TBI. Finally, in an effort to translate the technology, a (patent pending) handheld system has been developed. Simultaneously, fundus photography is combined with eye safe Raman spectroscopy, measuring high wavenumber bands from a three­dimensional printed tissue phantom of the undilated human eye.","abstract_has_math":false,"creators":["Banbury, Carl"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-07","date_published":"2021-07","updated_at":"2026-11-19T09:31:21Z","subjects":["QA75 Electronic computers. Computer science","QC Physics","QD Chemistry","RE Ophthalmology"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/L016346/1"],"render_values":[{"text":"EP/L016346/1","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/11353/7/Banbury2021PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A11353","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["epsrc"]},{"key":"dc:creator","label":"Author","values":["Banbury, Carl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-07-21"]},{"key":"dc:date.issued","label":"Date","values":["2021-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Chemical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/11353/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["QA75 Electronic computers. Computer science","QC Physics","QD Chemistry","RE Ophthalmology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["EP/L016346/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/11353/7/Banbury2021PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Traumatic brain injury (TBI) is a major burden on healthcare services worldwide, which currently lacks an effective method for point-­of­-care (PoC) diagnostics and monitoring. In this thesis, the prospect of using Raman spectroscopy, as a non­invasive means to mea­sure chemical changes indicative of TBI from the back of the eye is explored. Through the development of multivariate analysis methods, self­ organising maps are highlighted as a superior alternative to principal component analysis and are successfully used to in­troduce a new means of classification. A classification accuracy of > 93 % is demonstrated over five tissue types applied to anatomical layers of ocular porcine eyes. Subsequently, in a clinically relevant murine model of TBI, an ability to accurately identify TBI and in­jury severity from Raman spectra of the retina is demonstrated for the first time. Using feature extraction, intrinsically linked to the classification result, the findings are associ­ated with a decrease in cardiolipin linked to metabolic distress, which is a hallmark of TBI. Finally, in an effort to translate the technology, a (patent pending) handheld system has been developed. Simultaneously, fundus photography is combined with eye safe Raman spectroscopy, measuring high wavenumber bands from a three­dimensional printed tissue phantom of the undilated human eye."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Point of care diagnostics for traumatic brain injury"]}]}],"canonical_facts":{"dc:contributor.sponsor":["epsrc"],"dc:creator":["Banbury, Carl"],"dc:date":["2021-07-21"],"dc:date.issued":["2021-07"],"dc:description.abstract":["Traumatic brain injury (TBI) is a major burden on healthcare services worldwide, which currently lacks an effective method for point-­of­-care (PoC) diagnostics and monitoring. In this thesis, the prospect of using Raman spectroscopy, as a non­invasive means to mea­sure chemical changes indicative of TBI from the back of the eye is explored. Through the development of multivariate analysis methods, self­ organising maps are highlighted as a superior alternative to principal component analysis and are successfully used to in­troduce a new means of classification. A classification accuracy of > 93 % is demonstrated over five tissue types applied to anatomical layers of ocular porcine eyes. Subsequently, in a clinically relevant murine model of TBI, an ability to accurately identify TBI and in­jury severity from Raman spectra of the retina is demonstrated for the first time. Using feature extraction, intrinsically linked to the classification result, the findings are associ­ated with a decrease in cardiolipin linked to metabolic distress, which is a hallmark of TBI. Finally, in an effort to translate the technology, a (patent pending) handheld system has been developed. Simultaneously, fundus photography is combined with eye safe Raman spectroscopy, measuring high wavenumber bands from a three­dimensional printed tissue phantom of the undilated human eye."],"dc:format":["text"],"dc:identifier.grantnumber":["EP/L016346/1"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/11353/7/Banbury2021PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Chemical Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/11353/"],"dc:subject":["QA75 Electronic computers. Computer science","QC Physics","QD Chemistry","RE Ophthalmology"],"dcterms:accessrights":["public"],"dc:title":["Point of care diagnostics for traumatic brain injury"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:31:21Z"}