{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:16231"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:16231","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Development of antimicrobial metal alloys","abstract":"With rising rates of orthopaedic implant infections and antimicrobial resistance, novel methods to combat these clinical challenges are greatly needed. This thesis focusses on producing an inherently antimicrobial material to offer a localised solution for infection prevention. Ti-Cu alloys are investigated as potential candidates for biomedical alloys due to their evidenced antimicrobial efficacy. This thesis contributes knowledge to understanding what microstructural features drive the antimicrobial efficacy of Ti-Cu alloys and demonstrates that additive manufacturing may be used to amplify these effects. Initially, arc melted specimen of Ti-11.5 (wt.%) Cu and Ti-33 (wt.%) Cu were manufactured and heat treated to examine the influence of microstructural refinement to fine tune antimicrobial efficacy. Larger (approximately 5 µm), rounded TixCu precipitates had increased antimicrobial efficacy, compared to nanoscale and elongated precipitates, though no specimen showed efficacy towards E. coli. Further investigations using powder metallurgy and additive manufacturing demonstrated that processing routes markedly affect microstructure and copper ion release, enhancing antimicrobial potency. Notably, AM-fabricated alloys with only 3 wt.% Cu exhibited significant antimicrobial efficacy against both S. aureus and E. coli. Improvements in their responses to native bone cells were also prominent, with cell viability of 78 % and 51 % after 7 days for Ti-3Cu and Ti-11.5Cu respectively. However, concerns around the long-term biocompatibility of Ti-11.5Cu due to the ion release mechanism must be considered. Finally, to address concerns around the mechanical mismatches that may lead to aseptic loosening, the potential for developing a Ti-Mo-Cu alloy was explored. Using low laser energy densities and post-processing heat treatments, successful Mo diffusion was achieved. This led to fabrication of promising alloy systems with 100 % antimicrobial efficacy. These findings underscore the importance of compositional tuning and role of heat treatments in optimising both the mechanical integrity and biological functionality of titanium alloys for advanced biomedical applications.","abstract_html":"With rising rates of orthopaedic implant infections and antimicrobial resistance, novel methods to combat these clinical challenges are greatly needed. This thesis focusses on producing an inherently antimicrobial material to offer a localised solution for infection prevention. Ti-Cu alloys are investigated as potential candidates for biomedical alloys due to their evidenced antimicrobial efficacy. This thesis contributes knowledge to understanding what microstructural features drive the antimicrobial efficacy of Ti-Cu alloys and demonstrates that additive manufacturing may be used to amplify these effects. Initially, arc melted specimen of Ti-11.5 (wt.%) Cu and Ti-33 (wt.%) Cu were manufactured and heat treated to examine the influence of microstructural refinement to fine tune antimicrobial efficacy. Larger (approximately 5 µm), rounded TixCu precipitates had increased antimicrobial efficacy, compared to nanoscale and elongated precipitates, though no specimen showed efficacy towards E. coli. Further investigations using powder metallurgy and additive manufacturing demonstrated that processing routes markedly affect microstructure and copper ion release, enhancing antimicrobial potency. Notably, AM-fabricated alloys with only 3 wt.% Cu exhibited significant antimicrobial efficacy against both S. aureus and E. coli. Improvements in their responses to native bone cells were also prominent, with cell viability of 78 % and 51 % after 7 days for Ti-3Cu and Ti-11.5Cu respectively. However, concerns around the long-term biocompatibility of Ti-11.5Cu due to the ion release mechanism must be considered. Finally, to address concerns around the mechanical mismatches that may lead to aseptic loosening, the potential for developing a Ti-Mo-Cu alloy was explored. Using low laser energy densities and post-processing heat treatments, successful Mo diffusion was achieved. This led to fabrication of promising alloy systems with 100 % antimicrobial efficacy. These findings underscore the importance of compositional tuning and role of heat treatments in optimising both the mechanical integrity and biological functionality of titanium alloys for advanced biomedical applications.","abstract_has_math":false,"creators":["Rabbitt, Daisy Lily Adonia"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-07","date_published":"2025-07","updated_at":"2026-11-19T09:33:12Z","subjects":["Q Science (General)","QR Microbiology","TN Mining engineering. Metallurgy","TP Chemical technology"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["UKRI Future Leaders Fellowship [MR/T019174/1, MR/Y034155/1, MR/T017783/1]","UKRI Future Leaders Fellowship [MR/T019174/1, MR/Y034155/1"],"render_values":[{"text":"UKRI Future Leaders Fellowship [MR/T019174/1, MR/Y034155/1, MR/T017783/1]","href":null,"code":true},{"text":"UKRI Future Leaders Fellowship [MR/T019174/1, MR/Y034155/1","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.orcid","label":"ORCID","values":["0000000227270700"],"render_values":[{"text":"0000-0002-2727-0700","href":"https://orcid.org/0000-0002-2727-0700","code":true}]}]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/16231/7/Rabbitt2025PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A16231","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["epsrc"]},{"key":"dc:creator","label":"Author","values":["Rabbitt, Daisy Lily Adonia"]},{"key":"person:identifier.orcid","label":"ORCID","values":["0000000227270700"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-07-15"]},{"key":"dc:date.issued","label":"Date","values":["2025-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Chemical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/16231/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Q Science (General)","QR Microbiology","TN Mining engineering. Metallurgy","TP Chemical technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.grantnumber","label":"Dc Identifier Grantnumber","values":["UKRI Future Leaders Fellowship [MR/T019174/1, MR/Y034155/1, MR/T017783/1]","UKRI Future Leaders Fellowship [MR/T019174/1, MR/Y034155/1"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/16231/7/Rabbitt2025PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["With rising rates of orthopaedic implant infections and antimicrobial resistance, novel methods to combat these clinical challenges are greatly needed. This thesis focusses on producing an inherently antimicrobial material to offer a localised solution for infection prevention. Ti-Cu alloys are investigated as potential candidates for biomedical alloys due to their evidenced antimicrobial efficacy. This thesis contributes knowledge to understanding what microstructural features drive the antimicrobial efficacy of Ti-Cu alloys and demonstrates that additive manufacturing may be used to amplify these effects. Initially, arc melted specimen of Ti-11.5 (wt.%) Cu and Ti-33 (wt.%) Cu were manufactured and heat treated to examine the influence of microstructural refinement to fine tune antimicrobial efficacy. Larger (approximately 5 µm), rounded TixCu precipitates had increased antimicrobial efficacy, compared to nanoscale and elongated precipitates, though no specimen showed efficacy towards E. coli. Further investigations using powder metallurgy and additive manufacturing demonstrated that processing routes markedly affect microstructure and copper ion release, enhancing antimicrobial potency. Notably, AM-fabricated alloys with only 3 wt.% Cu exhibited significant antimicrobial efficacy against both S. aureus and E. coli. Improvements in their responses to native bone cells were also prominent, with cell viability of 78 % and 51 % after 7 days for Ti-3Cu and Ti-11.5Cu respectively. However, concerns around the long-term biocompatibility of Ti-11.5Cu due to the ion release mechanism must be considered. Finally, to address concerns around the mechanical mismatches that may lead to aseptic loosening, the potential for developing a Ti-Mo-Cu alloy was explored. Using low laser energy densities and post-processing heat treatments, successful Mo diffusion was achieved. This led to fabrication of promising alloy systems with 100 % antimicrobial efficacy. These findings underscore the importance of compositional tuning and role of heat treatments in optimising both the mechanical integrity and biological functionality of titanium alloys for advanced biomedical applications."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of antimicrobial metal alloys"]}]}],"canonical_facts":{"dc:contributor.sponsor":["epsrc"],"dc:creator":["Rabbitt, Daisy Lily Adonia"],"dc:date":["2025-07-15"],"dc:date.issued":["2025-07"],"dc:description.abstract":["With rising rates of orthopaedic implant infections and antimicrobial resistance, novel methods to combat these clinical challenges are greatly needed. This thesis focusses on producing an inherently antimicrobial material to offer a localised solution for infection prevention. Ti-Cu alloys are investigated as potential candidates for biomedical alloys due to their evidenced antimicrobial efficacy. This thesis contributes knowledge to understanding what microstructural features drive the antimicrobial efficacy of Ti-Cu alloys and demonstrates that additive manufacturing may be used to amplify these effects. Initially, arc melted specimen of Ti-11.5 (wt.%) Cu and Ti-33 (wt.%) Cu were manufactured and heat treated to examine the influence of microstructural refinement to fine tune antimicrobial efficacy. Larger (approximately 5 µm), rounded TixCu precipitates had increased antimicrobial efficacy, compared to nanoscale and elongated precipitates, though no specimen showed efficacy towards E. coli. Further investigations using powder metallurgy and additive manufacturing demonstrated that processing routes markedly affect microstructure and copper ion release, enhancing antimicrobial potency. Notably, AM-fabricated alloys with only 3 wt.% Cu exhibited significant antimicrobial efficacy against both S. aureus and E. coli. Improvements in their responses to native bone cells were also prominent, with cell viability of 78 % and 51 % after 7 days for Ti-3Cu and Ti-11.5Cu respectively. However, concerns around the long-term biocompatibility of Ti-11.5Cu due to the ion release mechanism must be considered. Finally, to address concerns around the mechanical mismatches that may lead to aseptic loosening, the potential for developing a Ti-Mo-Cu alloy was explored. Using low laser energy densities and post-processing heat treatments, successful Mo diffusion was achieved. This led to fabrication of promising alloy systems with 100 % antimicrobial efficacy. These findings underscore the importance of compositional tuning and role of heat treatments in optimising both the mechanical integrity and biological functionality of titanium alloys for advanced biomedical applications."],"dc:format":["text"],"dc:identifier.grantnumber":["UKRI Future Leaders Fellowship [MR/T019174/1, MR/Y034155/1, MR/T017783/1]","UKRI Future Leaders Fellowship [MR/T019174/1, MR/Y034155/1"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/16231/7/Rabbitt2025PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Chemical Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/16231/"],"dc:subject":["Q Science (General)","QR Microbiology","TN Mining engineering. Metallurgy","TP Chemical technology"],"dcterms:accessrights":["public"],"dc:title":["Development of antimicrobial metal alloys"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"],"person:identifier.orcid":["0000000227270700"]},"updated_at":"2026-11-19T09:33:12Z"}