{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:1701"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:1701","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Evaluating interventions to make healthcare safer: methodological analysis and case study","abstract":"This thesis describes study designs for the robust evaluation of complex patient safety interventions. Fundamentally, study designs available to measure the effectiveness of patient safety interventions fall into two categories – those that use contemporaneous controls, and those that do not. A review of the recent literature (245 citations) revealed that most studies were single-centre (63%), and the majority of these did not use contemporaneous controls (84%); whilst in multi-centre studies (37%) the number of studies using contemporaneous controls (49%) equalled the number of studies that that did not (51%). Studies that do not use contemporaneous controls dominate the literature, but they are weak and subject to bias. The thesis further discussed a case-study, as an exemplar for the evaluation of a highly complex patient safety intervention – the Safer Patients Initiative (SPI), which sought to generically strengthen hospitals, whilst improving frontline activities. The evaluation was a before and after study, with contemporaneous controls. It used mixed-methods, so that the triangulation of a one type of research finding could be reinforced when corroborated by the finding of another type. Uniquely, it also, compared the rates of change across control and SPI hospitals – an approach referred to as the “difference-in-difference” method.","abstract_html":"This thesis describes study designs for the robust evaluation of complex patient safety interventions. Fundamentally, study designs available to measure the effectiveness of patient safety interventions fall into two categories – those that use contemporaneous controls, and those that do not. A review of the recent literature (245 citations) revealed that most studies were single-centre (63%), and the majority of these did not use contemporaneous controls (84%); whilst in multi-centre studies (37%) the number of studies using contemporaneous controls (49%) equalled the number of studies that that did not (51%). Studies that do not use contemporaneous controls dominate the literature, but they are weak and subject to bias. The thesis further discussed a case-study, as an exemplar for the evaluation of a highly complex patient safety intervention – the Safer Patients Initiative (SPI), which sought to generically strengthen hospitals, whilst improving frontline activities. The evaluation was a before and after study, with contemporaneous controls. It used mixed-methods, so that the triangulation of a one type of research finding could be reinforced when corroborated by the finding of another type. Uniquely, it also, compared the rates of change across control and SPI hospitals – an approach referred to as the “difference-in-difference” method.","abstract_has_math":false,"creators":["Benning, Amirta"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-07","date_published":"2011-07","updated_at":"2026-11-19T09:26:45Z","subjects":["RA Public aspects of medicine"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/1701/1/Decl_IS_benning_11_PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A1701","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["mrc","other"]},{"key":"dc:creator","label":"Author","values":["Benning, Amirta"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-07"]},{"key":"dc:date.issued","label":"Date","values":["2011-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Medical & Dental Sciences","School of Health and Population Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/1701/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["RA Public aspects of medicine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/1701/1/Decl_IS_benning_11_PhD.pdf","http://etheses.bham.ac.uk//id/eprint/1701/2/benning_11_PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis describes study designs for the robust evaluation of complex patient safety interventions. Fundamentally, study designs available to measure the effectiveness of patient safety interventions fall into two categories – those that use contemporaneous controls, and those that do not. A review of the recent literature (245 citations) revealed that most studies were single-centre (63%), and the majority of these did not use contemporaneous controls (84%); whilst in multi-centre studies (37%) the number of studies using contemporaneous controls (49%) equalled the number of studies that that did not (51%). Studies that do not use contemporaneous controls dominate the literature, but they are weak and subject to bias. The thesis further discussed a case-study, as an exemplar for the evaluation of a highly complex patient safety intervention – the Safer Patients Initiative (SPI), which sought to generically strengthen hospitals, whilst improving frontline activities. The evaluation was a before and after study, with contemporaneous controls. It used mixed-methods, so that the triangulation of a one type of research finding could be reinforced when corroborated by the finding of another type. Uniquely, it also, compared the rates of change across control and SPI hospitals – an approach referred to as the “difference-in-difference” method."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["staffonly","public"]},{"key":"dc:title","label":"Title","values":["Evaluating interventions to make healthcare safer: methodological analysis and case study"]}]}],"canonical_facts":{"dc:contributor.sponsor":["mrc","other"],"dc:creator":["Benning, Amirta"],"dc:date":["2011-07"],"dc:date.issued":["2011-07"],"dc:description.abstract":["This thesis describes study designs for the robust evaluation of complex patient safety interventions. Fundamentally, study designs available to measure the effectiveness of patient safety interventions fall into two categories – those that use contemporaneous controls, and those that do not. A review of the recent literature (245 citations) revealed that most studies were single-centre (63%), and the majority of these did not use contemporaneous controls (84%); whilst in multi-centre studies (37%) the number of studies using contemporaneous controls (49%) equalled the number of studies that that did not (51%). Studies that do not use contemporaneous controls dominate the literature, but they are weak and subject to bias. The thesis further discussed a case-study, as an exemplar for the evaluation of a highly complex patient safety intervention – the Safer Patients Initiative (SPI), which sought to generically strengthen hospitals, whilst improving frontline activities. The evaluation was a before and after study, with contemporaneous controls. It used mixed-methods, so that the triangulation of a one type of research finding could be reinforced when corroborated by the finding of another type. Uniquely, it also, compared the rates of change across control and SPI hospitals – an approach referred to as the “difference-in-difference” method."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/1701/1/Decl_IS_benning_11_PhD.pdf","http://etheses.bham.ac.uk//id/eprint/1701/2/benning_11_PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Medical & Dental Sciences","School of Health and Population Sciences"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/1701/"],"dc:subject":["RA Public aspects of medicine"],"dcterms:accessrights":["staffonly","public"],"dc:title":["Evaluating interventions to make healthcare safer: methodological analysis and case study"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:26:45Z"}