{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:2816"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:2816","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Radiation dosimetry of conventional and laser-driven particle beams","abstract":"The measurement of radiation dose in radiotherapy is vital in ensuring the accuracy of treatments. As more advanced techniques using protons and ions emerge, they pose challenges to ensure the same level of accuracy of dosimetry is achieved as for conventional X-ray radiotherapy. A relatively new method of particle acceleration using ultra-high intensity lasers and thin metallic targets has sparked a large effort to investigate the possible application of this technology in radiotherapy, which in turn requires accurate methods of dosimetry to be carried out and is the main motivation for this work. Accurate dosimetry was initially performed here using an air ionisation chamber, various models of GafChromic film and a PMMA phantom in 15 and 29 MeV protons and 38 MeV \\(\\alpha\\)-particles from the Birmingham cyclotron. In developing an accurate protocol for absorbed dose-to-water at these relatively low proton energies, new data was generated on the proton energy response of GafChromic films. This enabled accurate dosimetry of a prototype laser-particle source, and provided improvements to a method of spectroscopic measurement in the resultant mixed field of multi-energy protons, electrons and X-rays. Monte Carlo simulations using MCNPX but mainly FLUKA were performed throughout to support and verify experimental measurements.","abstract_html":"The measurement of radiation dose in radiotherapy is vital in ensuring the accuracy of treatments. As more advanced techniques using protons and ions emerge, they pose challenges to ensure the same level of accuracy of dosimetry is achieved as for conventional X-ray radiotherapy. A relatively new method of particle acceleration using ultra-high intensity lasers and thin metallic targets has sparked a large effort to investigate the possible application of this technology in radiotherapy, which in turn requires accurate methods of dosimetry to be carried out and is the main motivation for this work. Accurate dosimetry was initially performed here using an air ionisation chamber, various models of GafChromic film and a PMMA phantom in 15 and 29 MeV protons and 38 MeV <span class=\"etd-inline-math\">&alpha;</span>-particles from the Birmingham cyclotron. In developing an accurate protocol for absorbed dose-to-water at these relatively low proton energies, new data was generated on the proton energy response of GafChromic films. This enabled accurate dosimetry of a prototype laser-particle source, and provided improvements to a method of spectroscopic measurement in the resultant mixed field of multi-energy protons, electrons and X-rays. Monte Carlo simulations using MCNPX but mainly FLUKA were performed throughout to support and verify experimental measurements.","abstract_has_math":true,"creators":["Kirby, Daniel James"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-12","date_published":"2011-12","updated_at":"2026-11-19T09:26:49Z","subjects":["QC Physics","R Medicine (General)"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/2816/1/Kirby11PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A2816","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Kirby, Daniel James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-12"]},{"key":"dc:date.issued","label":"Date","values":["2011-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Physics and Astronomy"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/2816/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["QC Physics","R Medicine (General)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/2816/1/Kirby11PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The measurement of radiation dose in radiotherapy is vital in ensuring the accuracy of treatments. As more advanced techniques using protons and ions emerge, they pose challenges to ensure the same level of accuracy of dosimetry is achieved as for conventional X-ray radiotherapy. A relatively new method of particle acceleration using ultra-high intensity lasers and thin metallic targets has sparked a large effort to investigate the possible application of this technology in radiotherapy, which in turn requires accurate methods of dosimetry to be carried out and is the main motivation for this work. Accurate dosimetry was initially performed here using an air ionisation chamber, various models of GafChromic film and a PMMA phantom in 15 and 29 MeV protons and 38 MeV \\(\\alpha\\)-particles from the Birmingham cyclotron. In developing an accurate protocol for absorbed dose-to-water at these relatively low proton energies, new data was generated on the proton energy response of GafChromic films. This enabled accurate dosimetry of a prototype laser-particle source, and provided improvements to a method of spectroscopic measurement in the resultant mixed field of multi-energy protons, electrons and X-rays. Monte Carlo simulations using MCNPX but mainly FLUKA were performed throughout to support and verify experimental measurements."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Radiation dosimetry of conventional and laser-driven particle beams"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Kirby, Daniel James"],"dc:date":["2011-12"],"dc:date.issued":["2011-12"],"dc:description.abstract":["The measurement of radiation dose in radiotherapy is vital in ensuring the accuracy of treatments. As more advanced techniques using protons and ions emerge, they pose challenges to ensure the same level of accuracy of dosimetry is achieved as for conventional X-ray radiotherapy. A relatively new method of particle acceleration using ultra-high intensity lasers and thin metallic targets has sparked a large effort to investigate the possible application of this technology in radiotherapy, which in turn requires accurate methods of dosimetry to be carried out and is the main motivation for this work. Accurate dosimetry was initially performed here using an air ionisation chamber, various models of GafChromic film and a PMMA phantom in 15 and 29 MeV protons and 38 MeV \\(\\alpha\\)-particles from the Birmingham cyclotron. In developing an accurate protocol for absorbed dose-to-water at these relatively low proton energies, new data was generated on the proton energy response of GafChromic films. This enabled accurate dosimetry of a prototype laser-particle source, and provided improvements to a method of spectroscopic measurement in the resultant mixed field of multi-energy protons, electrons and X-rays. Monte Carlo simulations using MCNPX but mainly FLUKA were performed throughout to support and verify experimental measurements."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/2816/1/Kirby11PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Physics and Astronomy"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/2816/"],"dc:subject":["QC Physics","R Medicine (General)"],"dcterms:accessrights":["public"],"dc:title":["Radiation dosimetry of conventional and laser-driven particle beams"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:26:49Z"}