{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:4128"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:4128","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Cleaning of toothpaste from process equipment by fluid flow at laboratory and pilot scales","abstract":"Cleaning studies were performed to remove toothpaste by fluid flow at different temperatures and velocities to mimic CIP (Cleaning-In-Place) processes on toothpaste coated coupons at laboratory scale and fully filled pipeline at pilot scale (different lengths and diameters). The cleaning time was reduced by increasing the velocity and temperature of the water, however no further time benefit was seen above 40°C. The adhesive force for different pastes calculated from micromanipulation data followed the same trend as cleaning times on the laboratory cleaning rig. This cleaning data for the different paste formulations had a logarithmic relationship with the viscosity term from the Herschel-Bulkley rheological model. Removal of toothpaste from pipes occurred by the core of the paste being removed from the centre of the pipe to leave a thin coating on the pipe wall, which was then eroded by flow. Pipes of lengths between 0.3 m and 2 m (47.7 mm diameter pipe) showed no difference in cleaning time. The rate limiting process was removal of the thin wall coating and therefore not a function of length. An inverse wall shear stress relationship with cleaning time was found to represent all the data, at all scales and under all conditions.","abstract_html":"Cleaning studies were performed to remove toothpaste by fluid flow at different temperatures and velocities to mimic CIP (Cleaning-In-Place) processes on toothpaste coated coupons at laboratory scale and fully filled pipeline at pilot scale (different lengths and diameters). The cleaning time was reduced by increasing the velocity and temperature of the water, however no further time benefit was seen above 40°C. The adhesive force for different pastes calculated from micromanipulation data followed the same trend as cleaning times on the laboratory cleaning rig. This cleaning data for the different paste formulations had a logarithmic relationship with the viscosity term from the Herschel-Bulkley rheological model. Removal of toothpaste from pipes occurred by the core of the paste being removed from the centre of the pipe to leave a thin coating on the pipe wall, which was then eroded by flow. Pipes of lengths between 0.3 m and 2 m (47.7 mm diameter pipe) showed no difference in cleaning time. The rate limiting process was removal of the thin wall coating and therefore not a function of length. An inverse wall shear stress relationship with cleaning time was found to represent all the data, at all scales and under all conditions.","abstract_has_math":false,"creators":["Cole, Pamela Anne"],"institution":"University of Birmingham","degree_name":"d_en","degree_level":"d_en","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-07","date_published":"2013-07","updated_at":"2026-11-19T09:27:33Z","subjects":["TP Chemical technology"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/4128/1/Cole13EngD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A4128","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["epsrc"]},{"key":"dc:creator","label":"Author","values":["Cole, Pamela Anne"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-07"]},{"key":"dc:date.issued","label":"Date","values":["2013-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Chemical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/4128/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_en"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_en"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TP Chemical technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/4128/1/Cole13EngD.pdf","http://etheses.bham.ac.uk//id/eprint/4128/2/Decl_IS_Cole13EngD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cleaning studies were performed to remove toothpaste by fluid flow at different temperatures and velocities to mimic CIP (Cleaning-In-Place) processes on toothpaste coated coupons at laboratory scale and fully filled pipeline at pilot scale (different lengths and diameters). The cleaning time was reduced by increasing the velocity and temperature of the water, however no further time benefit was seen above 40°C. The adhesive force for different pastes calculated from micromanipulation data followed the same trend as cleaning times on the laboratory cleaning rig. This cleaning data for the different paste formulations had a logarithmic relationship with the viscosity term from the Herschel-Bulkley rheological model. Removal of toothpaste from pipes occurred by the core of the paste being removed from the centre of the pipe to leave a thin coating on the pipe wall, which was then eroded by flow. Pipes of lengths between 0.3 m and 2 m (47.7 mm diameter pipe) showed no difference in cleaning time. The rate limiting process was removal of the thin wall coating and therefore not a function of length. An inverse wall shear stress relationship with cleaning time was found to represent all the data, at all scales and under all conditions."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Cleaning of toothpaste from process equipment by fluid flow at laboratory and pilot scales"]}]}],"canonical_facts":{"dc:contributor.sponsor":["epsrc"],"dc:creator":["Cole, Pamela Anne"],"dc:date":["2013-07"],"dc:date.issued":["2013-07"],"dc:description.abstract":["Cleaning studies were performed to remove toothpaste by fluid flow at different temperatures and velocities to mimic CIP (Cleaning-In-Place) processes on toothpaste coated coupons at laboratory scale and fully filled pipeline at pilot scale (different lengths and diameters). The cleaning time was reduced by increasing the velocity and temperature of the water, however no further time benefit was seen above 40°C. The adhesive force for different pastes calculated from micromanipulation data followed the same trend as cleaning times on the laboratory cleaning rig. This cleaning data for the different paste formulations had a logarithmic relationship with the viscosity term from the Herschel-Bulkley rheological model. Removal of toothpaste from pipes occurred by the core of the paste being removed from the centre of the pipe to leave a thin coating on the pipe wall, which was then eroded by flow. Pipes of lengths between 0.3 m and 2 m (47.7 mm diameter pipe) showed no difference in cleaning time. The rate limiting process was removal of the thin wall coating and therefore not a function of length. An inverse wall shear stress relationship with cleaning time was found to represent all the data, at all scales and under all conditions."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/4128/1/Cole13EngD.pdf","http://etheses.bham.ac.uk//id/eprint/4128/2/Decl_IS_Cole13EngD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Chemical Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/4128/"],"dc:subject":["TP Chemical technology"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Cleaning of toothpaste from process equipment by fluid flow at laboratory and pilot scales"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_en"],"dc:type.qualificationname":["d_en"]},"updated_at":"2026-11-19T09:27:33Z"}