{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:4307"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:4307","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"An investigation into fibre spreading","abstract":"An investigation into the effect of fibre spreading on the physical properties of filament wound tubes has been conducted. Two custom-built spreading rigs were experimentally tested for their ability to spread a single or multiple E-glass fibre bundles. Two sets of filament wound composite tubes were manufactured. One set was wound using a conventional resin bath system. The second set incorporated an optimised spreading station prior to the resin bath. The results of the analysis of physical properties suggest that fibre volume fraction is slightly lower in tubes wound using a spreading station and these tubes also have a higher void content. The average density values are relatively similar although the tubes wound with the spreading station have less variance in the individual values. Further analysis is needed to determine the effect of spreading during manufacture on the mechanical properties of filament wound composite tubes.","abstract_html":"An investigation into the effect of fibre spreading on the physical properties of filament wound tubes has been conducted. Two custom-built spreading rigs were experimentally tested for their ability to spread a single or multiple E-glass fibre bundles. Two sets of filament wound composite tubes were manufactured. One set was wound using a conventional resin bath system. The second set incorporated an optimised spreading station prior to the resin bath. The results of the analysis of physical properties suggest that fibre volume fraction is slightly lower in tubes wound using a spreading station and these tubes also have a higher void content. The average density values are relatively similar although the tubes wound with the spreading station have less variance in the individual values. Further analysis is needed to determine the effect of spreading during manufacture on the mechanical properties of filament wound composite tubes.","abstract_has_math":false,"creators":["Murray, Richard Cameron"],"institution":"University of Birmingham","degree_name":"m_rs","degree_level":"m_rs","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-07","date_published":"2013-07","updated_at":"2026-11-19T09:27:39Z","subjects":["TA Engineering (General). Civil engineering (General)","TN Mining engineering. Metallurgy"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/4307/1/Murray13MRes.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A4307","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Murray, Richard Cameron"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-07"]},{"key":"dc:date.issued","label":"Date","values":["2013-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/4307/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["m_rs"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["m_rs"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TA Engineering (General). Civil engineering (General)","TN Mining engineering. Metallurgy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/4307/1/Murray13MRes.pdf","http://etheses.bham.ac.uk//id/eprint/4307/2/Decl_IS_Murray13MRes.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An investigation into the effect of fibre spreading on the physical properties of filament wound tubes has been conducted. Two custom-built spreading rigs were experimentally tested for their ability to spread a single or multiple E-glass fibre bundles. Two sets of filament wound composite tubes were manufactured. One set was wound using a conventional resin bath system. The second set incorporated an optimised spreading station prior to the resin bath. The results of the analysis of physical properties suggest that fibre volume fraction is slightly lower in tubes wound using a spreading station and these tubes also have a higher void content. The average density values are relatively similar although the tubes wound with the spreading station have less variance in the individual values. Further analysis is needed to determine the effect of spreading during manufacture on the mechanical properties of filament wound composite tubes."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["An investigation into fibre spreading"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Murray, Richard Cameron"],"dc:date":["2013-07"],"dc:date.issued":["2013-07"],"dc:description.abstract":["An investigation into the effect of fibre spreading on the physical properties of filament wound tubes has been conducted. Two custom-built spreading rigs were experimentally tested for their ability to spread a single or multiple E-glass fibre bundles. Two sets of filament wound composite tubes were manufactured. One set was wound using a conventional resin bath system. The second set incorporated an optimised spreading station prior to the resin bath. The results of the analysis of physical properties suggest that fibre volume fraction is slightly lower in tubes wound using a spreading station and these tubes also have a higher void content. The average density values are relatively similar although the tubes wound with the spreading station have less variance in the individual values. Further analysis is needed to determine the effect of spreading during manufacture on the mechanical properties of filament wound composite tubes."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/4307/1/Murray13MRes.pdf","http://etheses.bham.ac.uk//id/eprint/4307/2/Decl_IS_Murray13MRes.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/4307/"],"dc:subject":["TA Engineering (General). Civil engineering (General)","TN Mining engineering. Metallurgy"],"dcterms:accessrights":["public","staffonly"],"dc:title":["An investigation into fibre spreading"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["m_rs"],"dc:type.qualificationname":["m_rs"]},"updated_at":"2026-11-19T09:27:39Z"}