{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:4361"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:4361","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Fatigue and fracture of the ultrahigh strength steel AerMet 100","abstract":"This thesis considers the fatigue and fracture behaviour of ultra-high strength steel, AerMet 100. Two variants of AerMet 100 were tested, which had different desulphurisation and deoxidation methods. The first was desulphurised and deoxidised using mischmetal, designated MMAerMet 100. The second was desulphurised using calcium and deoxidised using titanium, designated Ca-AerMet 100. Axial fatigue testing below the 0.2% proof stress was carried out between stress ranges of 900-1700 MPa. Fractography revealed that the fatigue initiation sites could be traced to non-metallic inclusions. Samples tested in the longitudinal orientation had better fatigue lives compared to samples tested in the transverse orientation. A stress intensity factor range at the cracked inclusion at the point of initial fatigue crack growth showed a good correlation with fatigue life. Ca-AerMet 100 consistently had a better fatigue life compared to MM-AerMet 100. Fracture toughness testing showed that both variants of AerMet 100 had similar fracture toughness values and fractured by micro-void coalescence. Fractography revealed that 90% of the fracture surface was made from voids formed from secondary particles with approximate diameters of 90 nm. The work suggests that changing the desulphurisation and deoxidation method for AerMet 100 has not significantly affected the fracture toughness.","abstract_html":"This thesis considers the fatigue and fracture behaviour of ultra-high strength steel, AerMet 100. Two variants of AerMet 100 were tested, which had different desulphurisation and deoxidation methods. The first was desulphurised and deoxidised using mischmetal, designated MMAerMet 100. The second was desulphurised using calcium and deoxidised using titanium, designated Ca-AerMet 100. Axial fatigue testing below the 0.2% proof stress was carried out between stress ranges of 900-1700 MPa. Fractography revealed that the fatigue initiation sites could be traced to non-metallic inclusions. Samples tested in the longitudinal orientation had better fatigue lives compared to samples tested in the transverse orientation. A stress intensity factor range at the cracked inclusion at the point of initial fatigue crack growth showed a good correlation with fatigue life. Ca-AerMet 100 consistently had a better fatigue life compared to MM-AerMet 100. Fracture toughness testing showed that both variants of AerMet 100 had similar fracture toughness values and fractured by micro-void coalescence. Fractography revealed that 90% of the fracture surface was made from voids formed from secondary particles with approximate diameters of 90 nm. The work suggests that changing the desulphurisation and deoxidation method for AerMet 100 has not significantly affected the fracture toughness.","abstract_has_math":false,"creators":["Hill, Paul Owen"],"institution":"University of Birmingham","degree_name":"d_en","degree_level":"d_en","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-12","date_published":"2012-12","updated_at":"2026-11-23T09:55:43Z","subjects":["TN Mining engineering. Metallurgy"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"https://etheses.bham.ac.uk/id/eprint/4361/1/Hill12EngD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A4361","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Hill, Paul Owen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-12"]},{"key":"dc:date.issued","label":"Date","values":["2012-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://etheses.bham.ac.uk/id/eprint/4361/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_en"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_en"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TN Mining engineering. Metallurgy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://etheses.bham.ac.uk/id/eprint/4361/1/Hill12EngD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis considers the fatigue and fracture behaviour of ultra-high strength steel, AerMet 100. Two variants of AerMet 100 were tested, which had different desulphurisation and deoxidation methods. The first was desulphurised and deoxidised using mischmetal, designated MMAerMet 100. The second was desulphurised using calcium and deoxidised using titanium, designated Ca-AerMet 100. Axial fatigue testing below the 0.2% proof stress was carried out between stress ranges of 900-1700 MPa. Fractography revealed that the fatigue initiation sites could be traced to non-metallic inclusions. Samples tested in the longitudinal orientation had better fatigue lives compared to samples tested in the transverse orientation. A stress intensity factor range at the cracked inclusion at the point of initial fatigue crack growth showed a good correlation with fatigue life. Ca-AerMet 100 consistently had a better fatigue life compared to MM-AerMet 100. Fracture toughness testing showed that both variants of AerMet 100 had similar fracture toughness values and fractured by micro-void coalescence. Fractography revealed that 90% of the fracture surface was made from voids formed from secondary particles with approximate diameters of 90 nm. The work suggests that changing the desulphurisation and deoxidation method for AerMet 100 has not significantly affected the fracture toughness."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Fatigue and fracture of the ultrahigh strength steel AerMet 100"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Hill, Paul Owen"],"dc:date":["2012-12"],"dc:date.issued":["2012-12"],"dc:description.abstract":["This thesis considers the fatigue and fracture behaviour of ultra-high strength steel, AerMet 100. Two variants of AerMet 100 were tested, which had different desulphurisation and deoxidation methods. The first was desulphurised and deoxidised using mischmetal, designated MMAerMet 100. The second was desulphurised using calcium and deoxidised using titanium, designated Ca-AerMet 100. Axial fatigue testing below the 0.2% proof stress was carried out between stress ranges of 900-1700 MPa. Fractography revealed that the fatigue initiation sites could be traced to non-metallic inclusions. Samples tested in the longitudinal orientation had better fatigue lives compared to samples tested in the transverse orientation. A stress intensity factor range at the cracked inclusion at the point of initial fatigue crack growth showed a good correlation with fatigue life. Ca-AerMet 100 consistently had a better fatigue life compared to MM-AerMet 100. Fracture toughness testing showed that both variants of AerMet 100 had similar fracture toughness values and fractured by micro-void coalescence. Fractography revealed that 90% of the fracture surface was made from voids formed from secondary particles with approximate diameters of 90 nm. The work suggests that changing the desulphurisation and deoxidation method for AerMet 100 has not significantly affected the fracture toughness."],"dc:format":["text"],"dc:identifier.uri":["https://etheses.bham.ac.uk/id/eprint/4361/1/Hill12EngD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["https://etheses.bham.ac.uk/id/eprint/4361/"],"dc:subject":["TN Mining engineering. Metallurgy"],"dcterms:accessrights":["public"],"dc:title":["Fatigue and fracture of the ultrahigh strength steel AerMet 100"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_en"],"dc:type.qualificationname":["d_en"]},"updated_at":"2026-11-23T09:55:43Z"}