{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:4378"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:4378","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Evaluation of poly-ether-ether-ketone (PEEK) for cervical disc replacement devices","abstract":"Poly-ether-ether-ketone (PEEK) is a high performance aromatic thermoplastic with proven biocompatibility. Recently, it has been proposed as a promising bearing material for cervical total disc replacement (TDR). A new bearing combination of PEEK-on-PEEK based self-mating articulation has been used, which may overcome current bearing materials related complications. For ball-on-socket based cervical TDR designs, PEEK based bearing articulation is expected to operate under a boundary lubrication regime regardless of the radial clearance used. The contact stress encountered by the bearing surfaces is insufficient to result in either material yield or fatigue failure. High-cycle fatigue tests were performed on PEEK 450G specimens via three-point flexural bending. The obtained fatigue results (104.1 ± 5.8 MPa) show superiority over the historical polymeric bearing material UHMWPE (31 MPa). Moreover, it demonstrates a good resistance to sterilisation and thermal ageing. Laboratory wear simulation was also conducted, using spine simulators and following ISO 18192-1 standard. For PEEK-on-PEEK self-mating articulation, a steady state wear rate of 1.0 ± 0.9 mg/million cycles is obtained, which is comparable as the historical bearing combination (UHMWPE against CoCrMo). The results of this work suggest that PEEK-on-PEEK based articulation is a possible alternative for future cervical TDR designs.","abstract_html":"Poly-ether-ether-ketone (PEEK) is a high performance aromatic thermoplastic with proven biocompatibility. Recently, it has been proposed as a promising bearing material for cervical total disc replacement (TDR). A new bearing combination of PEEK-on-PEEK based self-mating articulation has been used, which may overcome current bearing materials related complications. For ball-on-socket based cervical TDR designs, PEEK based bearing articulation is expected to operate under a boundary lubrication regime regardless of the radial clearance used. The contact stress encountered by the bearing surfaces is insufficient to result in either material yield or fatigue failure. High-cycle fatigue tests were performed on PEEK 450G specimens via three-point flexural bending. The obtained fatigue results (104.1 ± 5.8 MPa) show superiority over the historical polymeric bearing material UHMWPE (31 MPa). Moreover, it demonstrates a good resistance to sterilisation and thermal ageing. Laboratory wear simulation was also conducted, using spine simulators and following ISO 18192-1 standard. For PEEK-on-PEEK self-mating articulation, a steady state wear rate of 1.0 ± 0.9 mg/million cycles is obtained, which is comparable as the historical bearing combination (UHMWPE against CoCrMo). The results of this work suggest that PEEK-on-PEEK based articulation is a possible alternative for future cervical TDR designs.","abstract_has_math":false,"creators":["Xin, Hua"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-07","date_published":"2014-07","updated_at":"2026-11-19T09:27:39Z","subjects":["RD Surgery","TJ Mechanical engineering and machinery","TP Chemical technology"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/4378/1/Xin14PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A4378","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Xin, Hua"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-07"]},{"key":"dc:date.issued","label":"Date","values":["2014-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Mechanical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/4378/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["RD Surgery","TJ Mechanical engineering and machinery","TP Chemical technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/4378/1/Xin14PhD.pdf","http://etheses.bham.ac.uk//id/eprint/4378/8/Decl_IS_Xin14PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Poly-ether-ether-ketone (PEEK) is a high performance aromatic thermoplastic with proven biocompatibility. Recently, it has been proposed as a promising bearing material for cervical total disc replacement (TDR). A new bearing combination of PEEK-on-PEEK based self-mating articulation has been used, which may overcome current bearing materials related complications. For ball-on-socket based cervical TDR designs, PEEK based bearing articulation is expected to operate under a boundary lubrication regime regardless of the radial clearance used. The contact stress encountered by the bearing surfaces is insufficient to result in either material yield or fatigue failure. High-cycle fatigue tests were performed on PEEK 450G specimens via three-point flexural bending. The obtained fatigue results (104.1 ± 5.8 MPa) show superiority over the historical polymeric bearing material UHMWPE (31 MPa). Moreover, it demonstrates a good resistance to sterilisation and thermal ageing. Laboratory wear simulation was also conducted, using spine simulators and following ISO 18192-1 standard. For PEEK-on-PEEK self-mating articulation, a steady state wear rate of 1.0 ± 0.9 mg/million cycles is obtained, which is comparable as the historical bearing combination (UHMWPE against CoCrMo). The results of this work suggest that PEEK-on-PEEK based articulation is a possible alternative for future cervical TDR designs."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Evaluation of poly-ether-ether-ketone (PEEK) for cervical disc replacement devices"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Xin, Hua"],"dc:date":["2014-07"],"dc:date.issued":["2014-07"],"dc:description.abstract":["Poly-ether-ether-ketone (PEEK) is a high performance aromatic thermoplastic with proven biocompatibility. Recently, it has been proposed as a promising bearing material for cervical total disc replacement (TDR). A new bearing combination of PEEK-on-PEEK based self-mating articulation has been used, which may overcome current bearing materials related complications. For ball-on-socket based cervical TDR designs, PEEK based bearing articulation is expected to operate under a boundary lubrication regime regardless of the radial clearance used. The contact stress encountered by the bearing surfaces is insufficient to result in either material yield or fatigue failure. High-cycle fatigue tests were performed on PEEK 450G specimens via three-point flexural bending. The obtained fatigue results (104.1 ± 5.8 MPa) show superiority over the historical polymeric bearing material UHMWPE (31 MPa). Moreover, it demonstrates a good resistance to sterilisation and thermal ageing. Laboratory wear simulation was also conducted, using spine simulators and following ISO 18192-1 standard. For PEEK-on-PEEK self-mating articulation, a steady state wear rate of 1.0 ± 0.9 mg/million cycles is obtained, which is comparable as the historical bearing combination (UHMWPE against CoCrMo). The results of this work suggest that PEEK-on-PEEK based articulation is a possible alternative for future cervical TDR designs."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/4378/1/Xin14PhD.pdf","http://etheses.bham.ac.uk//id/eprint/4378/8/Decl_IS_Xin14PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Mechanical Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/4378/"],"dc:subject":["RD Surgery","TJ Mechanical engineering and machinery","TP Chemical technology"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Evaluation of poly-ether-ether-ketone (PEEK) for cervical disc replacement devices"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:27:39Z"}