{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:4422"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:4422","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Ageing of integrated-planar Solid Oxide Fuel Cells","abstract":"The ageing of Solid Oxide Fuel Cells (SOFCs) is a key problem because of the requirement of 50,000 hours to their lifetime in many applications. At present, such performance is still not attainable because degradation occurs at more than 1% per thousand hours under practical test conditions. In this thesis, the ageing of the Rolls Royce Fuel Cell Systems (RRFCS)Integrated Planar Solid Oxide Fuel Cell (IP-SOFC) was studied under different operating conditions, especially by accelerated degradation testing (ADT), in order to investigate the fuel cell stability and degradation behaviour under non-steady operating conditions for further improvement of the systems. This work demonstrates that the long-term durability of the IP-SOFC is very good when pure hydrogen is used as fuel. However, the introducing of even a small amount of methane in fuel has demonstrated the capacity to damage the IP-SOFC through the formation of carbon deposits on the anode surface. Future work is therefore required to identify viable alternative materials and optimal operating conditions.","abstract_html":"The ageing of Solid Oxide Fuel Cells (SOFCs) is a key problem because of the requirement of 50,000 hours to their lifetime in many applications. At present, such performance is still not attainable because degradation occurs at more than 1% per thousand hours under practical test conditions. In this thesis, the ageing of the Rolls Royce Fuel Cell Systems (RRFCS)Integrated Planar Solid Oxide Fuel Cell (IP-SOFC) was studied under different operating conditions, especially by accelerated degradation testing (ADT), in order to investigate the fuel cell stability and degradation behaviour under non-steady operating conditions for further improvement of the systems. This work demonstrates that the long-term durability of the IP-SOFC is very good when pure hydrogen is used as fuel. However, the introducing of even a small amount of methane in fuel has demonstrated the capacity to damage the IP-SOFC through the formation of carbon deposits on the anode surface. Future work is therefore required to identify viable alternative materials and optimal operating conditions.","abstract_has_math":false,"creators":["Almutairi, Ghzzai"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-12","date_published":"2013-12","updated_at":"2026-11-19T09:27:43Z","subjects":["TJ Mechanical engineering and machinery","TP Chemical technology"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/4422/1/Almutairi13PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A4422","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Almutairi, Ghzzai"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-12-01"]},{"key":"dc:date.issued","label":"Date","values":["2013-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/4422/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TJ Mechanical engineering and machinery","TP Chemical technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/4422/1/Almutairi13PhD.pdf","http://etheses.bham.ac.uk//id/eprint/4422/2/Decl_IS_Almutairi13PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The ageing of Solid Oxide Fuel Cells (SOFCs) is a key problem because of the requirement of 50,000 hours to their lifetime in many applications. At present, such performance is still not attainable because degradation occurs at more than 1% per thousand hours under practical test conditions. In this thesis, the ageing of the Rolls Royce Fuel Cell Systems (RRFCS)Integrated Planar Solid Oxide Fuel Cell (IP-SOFC) was studied under different operating conditions, especially by accelerated degradation testing (ADT), in order to investigate the fuel cell stability and degradation behaviour under non-steady operating conditions for further improvement of the systems. This work demonstrates that the long-term durability of the IP-SOFC is very good when pure hydrogen is used as fuel. However, the introducing of even a small amount of methane in fuel has demonstrated the capacity to damage the IP-SOFC through the formation of carbon deposits on the anode surface. Future work is therefore required to identify viable alternative materials and optimal operating conditions."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Ageing of integrated-planar Solid Oxide Fuel Cells"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Almutairi, Ghzzai"],"dc:date":["2013-12-01"],"dc:date.issued":["2013-12"],"dc:description.abstract":["The ageing of Solid Oxide Fuel Cells (SOFCs) is a key problem because of the requirement of 50,000 hours to their lifetime in many applications. At present, such performance is still not attainable because degradation occurs at more than 1% per thousand hours under practical test conditions. In this thesis, the ageing of the Rolls Royce Fuel Cell Systems (RRFCS)Integrated Planar Solid Oxide Fuel Cell (IP-SOFC) was studied under different operating conditions, especially by accelerated degradation testing (ADT), in order to investigate the fuel cell stability and degradation behaviour under non-steady operating conditions for further improvement of the systems. This work demonstrates that the long-term durability of the IP-SOFC is very good when pure hydrogen is used as fuel. However, the introducing of even a small amount of methane in fuel has demonstrated the capacity to damage the IP-SOFC through the formation of carbon deposits on the anode surface. Future work is therefore required to identify viable alternative materials and optimal operating conditions."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/4422/1/Almutairi13PhD.pdf","http://etheses.bham.ac.uk//id/eprint/4422/2/Decl_IS_Almutairi13PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/4422/"],"dc:subject":["TJ Mechanical engineering and machinery","TP Chemical technology"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Ageing of integrated-planar Solid Oxide Fuel Cells"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:27:43Z"}