{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:5199"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:5199","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Investigations on structural interaction of cold-formed steel roof purlin-sheet system","abstract":"When used as secondary roof purlins, cold-formed steel (CFS) sections are often attached to trapezoidal sheets through self-drilling screws to form a complete roofing system. The load application points are often eccentric to the shear centre, and thus inevitably generate a torsional moment that will induce twisting and/or warping deformations in addition to bending deflection. The connections between purlin and roof sheeting provide a restraining effect on purlin members by preventing such lateral and twisting movements, and hence have a beneficial effect on the load-carrying capacity. In this thesis the interactional behaviour of CFS purlin-sheeting system have been investigated through the following steps: (1) A F-test is carried out to measure the rotational stiffness at the connections, an engineering-orientated model is developed for quantifying the rotational stiffness regardless to purlin and sheet geometry and loading directions; (2) A set of loading tests on Z- and Σ- roof system are conducted to investigate the impact of rotational stiffness on the overall structural performance, load-carrying capacity and buckling behaviour of the system; (3) Finite element simulations of the existing tests are carried out and successfully validated; (4) Numerical parametric studies are established to study other factors that could affect the rotational stiffness.","abstract_html":"When used as secondary roof purlins, cold-formed steel (CFS) sections are often attached to trapezoidal sheets through self-drilling screws to form a complete roofing system. The load application points are often eccentric to the shear centre, and thus inevitably generate a torsional moment that will induce twisting and/or warping deformations in addition to bending deflection. The connections between purlin and roof sheeting provide a restraining effect on purlin members by preventing such lateral and twisting movements, and hence have a beneficial effect on the load-carrying capacity. In this thesis the interactional behaviour of CFS purlin-sheeting system have been investigated through the following steps: (1) A F-test is carried out to measure the rotational stiffness at the connections, an engineering-orientated model is developed for quantifying the rotational stiffness regardless to purlin and sheet geometry and loading directions; (2) A set of loading tests on Z- and Σ- roof system are conducted to investigate the impact of rotational stiffness on the overall structural performance, load-carrying capacity and buckling behaviour of the system; (3) Finite element simulations of the existing tests are carried out and successfully validated; (4) Numerical parametric studies are established to study other factors that could affect the rotational stiffness.","abstract_has_math":false,"creators":["Zhao, Congxiao"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-07","date_published":"2014-07","updated_at":"2026-11-19T09:28:14Z","subjects":["TA Engineering (General). Civil engineering (General)","TH Building construction"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/5199/2/Zhao14PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A5199","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["epsrc"]},{"key":"dc:creator","label":"Author","values":["Zhao, Congxiao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-07"]},{"key":"dc:date.issued","label":"Date","values":["2014-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/5199/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TA Engineering (General). Civil engineering (General)","TH Building construction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/5199/2/Zhao14PhD.pdf","http://etheses.bham.ac.uk//id/eprint/5199/1/Decl_IS_Zhao14PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["When used as secondary roof purlins, cold-formed steel (CFS) sections are often attached to trapezoidal sheets through self-drilling screws to form a complete roofing system. The load application points are often eccentric to the shear centre, and thus inevitably generate a torsional moment that will induce twisting and/or warping deformations in addition to bending deflection. The connections between purlin and roof sheeting provide a restraining effect on purlin members by preventing such lateral and twisting movements, and hence have a beneficial effect on the load-carrying capacity. In this thesis the interactional behaviour of CFS purlin-sheeting system have been investigated through the following steps: (1) A F-test is carried out to measure the rotational stiffness at the connections, an engineering-orientated model is developed for quantifying the rotational stiffness regardless to purlin and sheet geometry and loading directions; (2) A set of loading tests on Z- and Σ- roof system are conducted to investigate the impact of rotational stiffness on the overall structural performance, load-carrying capacity and buckling behaviour of the system; (3) Finite element simulations of the existing tests are carried out and successfully validated; (4) Numerical parametric studies are established to study other factors that could affect the rotational stiffness."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Investigations on structural interaction of cold-formed steel roof purlin-sheet system"]}]}],"canonical_facts":{"dc:contributor.sponsor":["epsrc"],"dc:creator":["Zhao, Congxiao"],"dc:date":["2014-07"],"dc:date.issued":["2014-07"],"dc:description.abstract":["When used as secondary roof purlins, cold-formed steel (CFS) sections are often attached to trapezoidal sheets through self-drilling screws to form a complete roofing system. The load application points are often eccentric to the shear centre, and thus inevitably generate a torsional moment that will induce twisting and/or warping deformations in addition to bending deflection. The connections between purlin and roof sheeting provide a restraining effect on purlin members by preventing such lateral and twisting movements, and hence have a beneficial effect on the load-carrying capacity. In this thesis the interactional behaviour of CFS purlin-sheeting system have been investigated through the following steps: (1) A F-test is carried out to measure the rotational stiffness at the connections, an engineering-orientated model is developed for quantifying the rotational stiffness regardless to purlin and sheet geometry and loading directions; (2) A set of loading tests on Z- and Σ- roof system are conducted to investigate the impact of rotational stiffness on the overall structural performance, load-carrying capacity and buckling behaviour of the system; (3) Finite element simulations of the existing tests are carried out and successfully validated; (4) Numerical parametric studies are established to study other factors that could affect the rotational stiffness."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/5199/2/Zhao14PhD.pdf","http://etheses.bham.ac.uk//id/eprint/5199/1/Decl_IS_Zhao14PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/5199/"],"dc:subject":["TA Engineering (General). Civil engineering (General)","TH Building construction"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Investigations on structural interaction of cold-formed steel roof purlin-sheet system"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:28:14Z"}