{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:5289"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:5289","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Structural and functional integrity of energy-efficiency glazing units","abstract":"Windows are the least insulated components in the modern buildings envelopes. The energy-efficiency glazing units have been developed and used to reduce the heat loss from windows. As a type of most common glass product, insulating glass units (IGUs) have been widely adopted in the residential and commercial buildings. A type of new design of glazing units, vacuum glazing units (VGUs), has also been developed to further enhance the insulation performance. Research on the structural/durability behaviours of such new insulating glazing units is relatively limited, although the structural behaviours and safety of monolithic or laminated glass panels have been abundantly studied. This thesis intends to fill in this gap by performing thorough assessments on the structural performance of IGUs and VGUs under various environmental actions.","abstract_html":"Windows are the least insulated components in the modern buildings envelopes. The energy-efficiency glazing units have been developed and used to reduce the heat loss from windows. As a type of most common glass product, insulating glass units (IGUs) have been widely adopted in the residential and commercial buildings. A type of new design of glazing units, vacuum glazing units (VGUs), has also been developed to further enhance the insulation performance. Research on the structural/durability behaviours of such new insulating glazing units is relatively limited, although the structural behaviours and safety of monolithic or laminated glass panels have been abundantly studied. This thesis intends to fill in this gap by performing thorough assessments on the structural performance of IGUs and VGUs under various environmental actions.","abstract_has_math":false,"creators":["Bao, Minxi"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-12","date_published":"2014-12","updated_at":"2026-11-19T09:28:20Z","subjects":["TA Engineering (General). Civil engineering (General)","TD Environmental technology. Sanitary engineering"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/5289/1/Bao14PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A5289","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Bao, Minxi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-12"]},{"key":"dc:date.issued","label":"Date","values":["2014-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/5289/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TA Engineering (General). Civil engineering (General)","TD Environmental technology. Sanitary engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/5289/1/Bao14PhD.pdf","http://etheses.bham.ac.uk//id/eprint/5289/2/Decl_IS_Bao14PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Windows are the least insulated components in the modern buildings envelopes. The energy-efficiency glazing units have been developed and used to reduce the heat loss from windows. As a type of most common glass product, insulating glass units (IGUs) have been widely adopted in the residential and commercial buildings. A type of new design of glazing units, vacuum glazing units (VGUs), has also been developed to further enhance the insulation performance. Research on the structural/durability behaviours of such new insulating glazing units is relatively limited, although the structural behaviours and safety of monolithic or laminated glass panels have been abundantly studied. This thesis intends to fill in this gap by performing thorough assessments on the structural performance of IGUs and VGUs under various environmental actions."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Structural and functional integrity of energy-efficiency glazing units"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Bao, Minxi"],"dc:date":["2014-12"],"dc:date.issued":["2014-12"],"dc:description.abstract":["Windows are the least insulated components in the modern buildings envelopes. The energy-efficiency glazing units have been developed and used to reduce the heat loss from windows. As a type of most common glass product, insulating glass units (IGUs) have been widely adopted in the residential and commercial buildings. A type of new design of glazing units, vacuum glazing units (VGUs), has also been developed to further enhance the insulation performance. Research on the structural/durability behaviours of such new insulating glazing units is relatively limited, although the structural behaviours and safety of monolithic or laminated glass panels have been abundantly studied. This thesis intends to fill in this gap by performing thorough assessments on the structural performance of IGUs and VGUs under various environmental actions."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/5289/1/Bao14PhD.pdf","http://etheses.bham.ac.uk//id/eprint/5289/2/Decl_IS_Bao14PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/5289/"],"dc:subject":["TA Engineering (General). Civil engineering (General)","TD Environmental technology. Sanitary engineering"],"dcterms:accessrights":["public"],"dc:title":["Structural and functional integrity of energy-efficiency glazing units"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:28:20Z"}