{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:5301"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:5301","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Microstructure and degradation behaviour of Mg-Zn(-Ca) alloys","abstract":"Magnesium alloys are promising candidates for biomedical applications because of their advantageous properties. However, a too high degradation rate can be a problem. It is not desirable for the material to degrade completely before tissue healing has taken place. In this study, the relationship between the microstructure and bio-corrosion behaviour of Mg-3Zn(-0.3Ca) were analysed. It was found that nano-scale precipitates formed during ageing of Mg-Zn decrease the corrosion resistance. The increase in bio-corrosion rate with ageing time appears to be monotonic. The parallel filament-like corrosion trenches mirror the growth direction of the precipitates. The grain size and volume fraction of second phases are both key factors for controlling the bio-corrosion rate of Mg-Zn-Ca. The minimum corrosion rate was observed in the Mg-Zn-Ca solution treated at 420 \\(^o\\)C for 24 hours which has a balanced second phase volume fraction and grain size. 3D FIB and MicroCT tomography were used to show the internal structure of as-cast Mg-Zn and Mg-Zn-Ca. 3D reconstructions of corroded as-cast MZ3 and MZX30 were also shown. An HA (Ca5(PO4)3\\(^.\\)(OH)) coating was formed on Mg alloys. It was found that the pitting corrosion on the HA-coated alloys occurs and HA coating cannot provide sufficient protection to the Mg substrate.","abstract_html":"Magnesium alloys are promising candidates for biomedical applications because of their advantageous properties. However, a too high degradation rate can be a problem. It is not desirable for the material to degrade completely before tissue healing has taken place. In this study, the relationship between the microstructure and bio-corrosion behaviour of Mg-3Zn(-0.3Ca) were analysed. It was found that nano-scale precipitates formed during ageing of Mg-Zn decrease the corrosion resistance. The increase in bio-corrosion rate with ageing time appears to be monotonic. The parallel filament-like corrosion trenches mirror the growth direction of the precipitates. The grain size and volume fraction of second phases are both key factors for controlling the bio-corrosion rate of Mg-Zn-Ca. The minimum corrosion rate was observed in the Mg-Zn-Ca solution treated at 420 <span class=\"etd-inline-math\"><sup>o</sup></span>C for 24 hours which has a balanced second phase volume fraction and grain size. 3D FIB and MicroCT tomography were used to show the internal structure of as-cast Mg-Zn and Mg-Zn-Ca. 3D reconstructions of corroded as-cast MZ3 and MZX30 were also shown. An HA (Ca5(PO4)3<span class=\"etd-inline-math\"><sup>.</sup></span>(OH)) coating was formed on Mg alloys. It was found that the pitting corrosion on the HA-coated alloys occurs and HA coating cannot provide sufficient protection to the Mg substrate.","abstract_has_math":true,"creators":["Lu, Yu"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-12","date_published":"2014-12","updated_at":"2026-11-19T09:28:20Z","subjects":["TN Mining engineering. Metallurgy"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/5301/2/Lu14PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A5301","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["other"]},{"key":"dc:creator","label":"Author","values":["Lu, Yu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-12"]},{"key":"dc:date.issued","label":"Date","values":["2014-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/5301/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TN Mining engineering. Metallurgy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/5301/2/Lu14PhD.pdf","http://etheses.bham.ac.uk//id/eprint/5301/1/Decl_IS_Lu14PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Magnesium alloys are promising candidates for biomedical applications because of their advantageous properties. However, a too high degradation rate can be a problem. It is not desirable for the material to degrade completely before tissue healing has taken place. In this study, the relationship between the microstructure and bio-corrosion behaviour of Mg-3Zn(-0.3Ca) were analysed. It was found that nano-scale precipitates formed during ageing of Mg-Zn decrease the corrosion resistance. The increase in bio-corrosion rate with ageing time appears to be monotonic. The parallel filament-like corrosion trenches mirror the growth direction of the precipitates. The grain size and volume fraction of second phases are both key factors for controlling the bio-corrosion rate of Mg-Zn-Ca. The minimum corrosion rate was observed in the Mg-Zn-Ca solution treated at 420 \\(^o\\)C for 24 hours which has a balanced second phase volume fraction and grain size. 3D FIB and MicroCT tomography were used to show the internal structure of as-cast Mg-Zn and Mg-Zn-Ca. 3D reconstructions of corroded as-cast MZ3 and MZX30 were also shown. An HA (Ca5(PO4)3\\(^.\\)(OH)) coating was formed on Mg alloys. It was found that the pitting corrosion on the HA-coated alloys occurs and HA coating cannot provide sufficient protection to the Mg substrate."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Microstructure and degradation behaviour of Mg-Zn(-Ca) alloys"]}]}],"canonical_facts":{"dc:contributor.sponsor":["other"],"dc:creator":["Lu, Yu"],"dc:date":["2014-12"],"dc:date.issued":["2014-12"],"dc:description.abstract":["Magnesium alloys are promising candidates for biomedical applications because of their advantageous properties. However, a too high degradation rate can be a problem. It is not desirable for the material to degrade completely before tissue healing has taken place. In this study, the relationship between the microstructure and bio-corrosion behaviour of Mg-3Zn(-0.3Ca) were analysed. It was found that nano-scale precipitates formed during ageing of Mg-Zn decrease the corrosion resistance. The increase in bio-corrosion rate with ageing time appears to be monotonic. The parallel filament-like corrosion trenches mirror the growth direction of the precipitates. The grain size and volume fraction of second phases are both key factors for controlling the bio-corrosion rate of Mg-Zn-Ca. The minimum corrosion rate was observed in the Mg-Zn-Ca solution treated at 420 \\(^o\\)C for 24 hours which has a balanced second phase volume fraction and grain size. 3D FIB and MicroCT tomography were used to show the internal structure of as-cast Mg-Zn and Mg-Zn-Ca. 3D reconstructions of corroded as-cast MZ3 and MZX30 were also shown. An HA (Ca5(PO4)3\\(^.\\)(OH)) coating was formed on Mg alloys. It was found that the pitting corrosion on the HA-coated alloys occurs and HA coating cannot provide sufficient protection to the Mg substrate."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/5301/2/Lu14PhD.pdf","http://etheses.bham.ac.uk//id/eprint/5301/1/Decl_IS_Lu14PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/5301/"],"dc:subject":["TN Mining engineering. Metallurgy"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Microstructure and degradation behaviour of Mg-Zn(-Ca) alloys"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:28:20Z"}