{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:5874"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:5874","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Corrosion of titanium for biomedical applications","abstract":"Ti has been widely used in biomedical fields since the 1950s because of biocompatibility, corrosion resistance and suitable mechanical properties. However, corrosion-related failures of Ti implants are observed. Ti corrosion products are reported to induce unfavourable biological responses, which may lead to failures of Ti implants. Corrosion of three grades of Ti (CP-Ti Grade2, CP-Ti Grade4 and Ti6Al4V) in simulated peri-implant environments was investigated by solution analysis, surface analysis and electrochemical tests. Lipopolysaccharide, a component of bacterial cell walls and a mediator of peri-implant inflammation, was observed to enhance Ti corrosion in slightly acidic and neutral conditions (pH 4-7) whilst it inhibited Ti dissolution in highly acidic environments (pH 2). Both albumin, an abundant protein, and H\\(_2\\)O\\(_2\\), an important inflammation product, influenced corrosion of Ti6Al4V and the co-existence of both species considerably enhanced Ti release than either species in isolation. The β phase of Ti6Al4V was preferentially attacked in H\\(_2\\)O\\(_2\\). The presence of an early coloniser of dental implants Streptococcus sanguinis and human neutrophils, abundant immune cells, promoted Ti release. Mechanically-assisted crevice corrosion simulation was demonstrated with development of aggressive crevice chemistry. Albumin decreased the abrasion charge of Ti6Al4V while LPS and H2O2 did not show a measurable change.","abstract_html":"Ti has been widely used in biomedical fields since the 1950s because of biocompatibility, corrosion resistance and suitable mechanical properties. However, corrosion-related failures of Ti implants are observed. Ti corrosion products are reported to induce unfavourable biological responses, which may lead to failures of Ti implants. Corrosion of three grades of Ti (CP-Ti Grade2, CP-Ti Grade4 and Ti6Al4V) in simulated peri-implant environments was investigated by solution analysis, surface analysis and electrochemical tests. Lipopolysaccharide, a component of bacterial cell walls and a mediator of peri-implant inflammation, was observed to enhance Ti corrosion in slightly acidic and neutral conditions (pH 4-7) whilst it inhibited Ti dissolution in highly acidic environments (pH 2). Both albumin, an abundant protein, and H<span class=\"etd-inline-math\"><sub>2</sub></span>O<span class=\"etd-inline-math\"><sub>2</sub></span>, an important inflammation product, influenced corrosion of Ti6Al4V and the co-existence of both species considerably enhanced Ti release than either species in isolation. The β phase of Ti6Al4V was preferentially attacked in H<span class=\"etd-inline-math\"><sub>2</sub></span>O<span class=\"etd-inline-math\"><sub>2</sub></span>. The presence of an early coloniser of dental implants Streptococcus sanguinis and human neutrophils, abundant immune cells, promoted Ti release. Mechanically-assisted crevice corrosion simulation was demonstrated with development of aggressive crevice chemistry. Albumin decreased the abrasion charge of Ti6Al4V while LPS and H2O2 did not show a measurable change.","abstract_has_math":true,"creators":["Yu, Fei"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-07","date_published":"2015-07","updated_at":"2026-11-19T09:28:38Z","subjects":["R Medicine (General)","TN Mining engineering. Metallurgy"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/5874/1/Yu15PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A5874","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["other"]},{"key":"dc:creator","label":"Author","values":["Yu, Fei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-07"]},{"key":"dc:date.issued","label":"Date","values":["2015-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/5874/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["R Medicine (General)","TN Mining engineering. Metallurgy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/5874/1/Yu15PhD.pdf","http://etheses.bham.ac.uk//id/eprint/5874/2/Decl_IS_Yu15PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Ti has been widely used in biomedical fields since the 1950s because of biocompatibility, corrosion resistance and suitable mechanical properties. However, corrosion-related failures of Ti implants are observed. Ti corrosion products are reported to induce unfavourable biological responses, which may lead to failures of Ti implants. Corrosion of three grades of Ti (CP-Ti Grade2, CP-Ti Grade4 and Ti6Al4V) in simulated peri-implant environments was investigated by solution analysis, surface analysis and electrochemical tests. Lipopolysaccharide, a component of bacterial cell walls and a mediator of peri-implant inflammation, was observed to enhance Ti corrosion in slightly acidic and neutral conditions (pH 4-7) whilst it inhibited Ti dissolution in highly acidic environments (pH 2). Both albumin, an abundant protein, and H\\(_2\\)O\\(_2\\), an important inflammation product, influenced corrosion of Ti6Al4V and the co-existence of both species considerably enhanced Ti release than either species in isolation. The β phase of Ti6Al4V was preferentially attacked in H\\(_2\\)O\\(_2\\). The presence of an early coloniser of dental implants Streptococcus sanguinis and human neutrophils, abundant immune cells, promoted Ti release. Mechanically-assisted crevice corrosion simulation was demonstrated with development of aggressive crevice chemistry. Albumin decreased the abrasion charge of Ti6Al4V while LPS and H2O2 did not show a measurable change."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Corrosion of titanium for biomedical applications"]}]}],"canonical_facts":{"dc:contributor.sponsor":["other"],"dc:creator":["Yu, Fei"],"dc:date":["2015-07"],"dc:date.issued":["2015-07"],"dc:description.abstract":["Ti has been widely used in biomedical fields since the 1950s because of biocompatibility, corrosion resistance and suitable mechanical properties. However, corrosion-related failures of Ti implants are observed. Ti corrosion products are reported to induce unfavourable biological responses, which may lead to failures of Ti implants. Corrosion of three grades of Ti (CP-Ti Grade2, CP-Ti Grade4 and Ti6Al4V) in simulated peri-implant environments was investigated by solution analysis, surface analysis and electrochemical tests. Lipopolysaccharide, a component of bacterial cell walls and a mediator of peri-implant inflammation, was observed to enhance Ti corrosion in slightly acidic and neutral conditions (pH 4-7) whilst it inhibited Ti dissolution in highly acidic environments (pH 2). Both albumin, an abundant protein, and H\\(_2\\)O\\(_2\\), an important inflammation product, influenced corrosion of Ti6Al4V and the co-existence of both species considerably enhanced Ti release than either species in isolation. The β phase of Ti6Al4V was preferentially attacked in H\\(_2\\)O\\(_2\\). The presence of an early coloniser of dental implants Streptococcus sanguinis and human neutrophils, abundant immune cells, promoted Ti release. Mechanically-assisted crevice corrosion simulation was demonstrated with development of aggressive crevice chemistry. Albumin decreased the abrasion charge of Ti6Al4V while LPS and H2O2 did not show a measurable change."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/5874/1/Yu15PhD.pdf","http://etheses.bham.ac.uk//id/eprint/5874/2/Decl_IS_Yu15PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/5874/"],"dc:subject":["R Medicine (General)","TN Mining engineering. Metallurgy"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Corrosion of titanium for biomedical applications"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:28:38Z"}