{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:6227"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:6227","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Improvement of the structural response of steel tubular wind turbine towers by means of stiffeners","abstract":"In the thesis the structural response of steel tubular wind turbine towers with various design configurations is analysed using FEM modelling. First, a structural response simulation model was validated by comparison with the existing experimental data. This was then followed with a mesh density sensitivity analysis to obtain the optimum element size. Based on this outcome, towers of various heights between 50-250m are considered and investigated with three different design options as follows: (i) thick walled tower with internal horizontal stiffening rings, (ii) thick walled tower without stiffening rings and (iii) thin walled tower with stiffening rings. Based on this analysis, weight reduction ratios are examined in relation to the horizontal sway and von Mises stress increase ratios in order to identify a more efficient design approach between reducing the wall thickness and adopting internal stiffeners. All studied design solutions satisfy the strength and serviceability requirements as specified by the design codes of practice.","abstract_html":"In the thesis the structural response of steel tubular wind turbine towers with various design configurations is analysed using FEM modelling. First, a structural response simulation model was validated by comparison with the existing experimental data. This was then followed with a mesh density sensitivity analysis to obtain the optimum element size. Based on this outcome, towers of various heights between 50-250m are considered and investigated with three different design options as follows: (i) thick walled tower with internal horizontal stiffening rings, (ii) thick walled tower without stiffening rings and (iii) thin walled tower with stiffening rings. Based on this analysis, weight reduction ratios are examined in relation to the horizontal sway and von Mises stress increase ratios in order to identify a more efficient design approach between reducing the wall thickness and adopting internal stiffeners. All studied design solutions satisfy the strength and serviceability requirements as specified by the design codes of practice.","abstract_has_math":false,"creators":["Hu, Yu"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-12","date_published":"2015-12","updated_at":"2026-11-19T09:28:46Z","subjects":["TA Engineering (General). Civil engineering (General)","TD Environmental technology. Sanitary engineering"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/6227/7/Hu15PhD1.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A6227","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Hu, Yu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-12"]},{"key":"dc:date.issued","label":"Date","values":["2015-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/6227/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TA Engineering (General). Civil engineering (General)","TD Environmental technology. Sanitary engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/6227/7/Hu15PhD1.pdf","http://etheses.bham.ac.uk//id/eprint/6227/2/Decl_IS_Hu15PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In the thesis the structural response of steel tubular wind turbine towers with various design configurations is analysed using FEM modelling. First, a structural response simulation model was validated by comparison with the existing experimental data. This was then followed with a mesh density sensitivity analysis to obtain the optimum element size. Based on this outcome, towers of various heights between 50-250m are considered and investigated with three different design options as follows: (i) thick walled tower with internal horizontal stiffening rings, (ii) thick walled tower without stiffening rings and (iii) thin walled tower with stiffening rings. Based on this analysis, weight reduction ratios are examined in relation to the horizontal sway and von Mises stress increase ratios in order to identify a more efficient design approach between reducing the wall thickness and adopting internal stiffeners. All studied design solutions satisfy the strength and serviceability requirements as specified by the design codes of practice."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Improvement of the structural response of steel tubular wind turbine towers by means of stiffeners"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Hu, Yu"],"dc:date":["2015-12"],"dc:date.issued":["2015-12"],"dc:description.abstract":["In the thesis the structural response of steel tubular wind turbine towers with various design configurations is analysed using FEM modelling. First, a structural response simulation model was validated by comparison with the existing experimental data. This was then followed with a mesh density sensitivity analysis to obtain the optimum element size. Based on this outcome, towers of various heights between 50-250m are considered and investigated with three different design options as follows: (i) thick walled tower with internal horizontal stiffening rings, (ii) thick walled tower without stiffening rings and (iii) thin walled tower with stiffening rings. Based on this analysis, weight reduction ratios are examined in relation to the horizontal sway and von Mises stress increase ratios in order to identify a more efficient design approach between reducing the wall thickness and adopting internal stiffeners. All studied design solutions satisfy the strength and serviceability requirements as specified by the design codes of practice."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/6227/7/Hu15PhD1.pdf","http://etheses.bham.ac.uk//id/eprint/6227/2/Decl_IS_Hu15PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/6227/"],"dc:subject":["TA Engineering (General). Civil engineering (General)","TD Environmental technology. Sanitary engineering"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Improvement of the structural response of steel tubular wind turbine towers by means of stiffeners"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:28:46Z"}