{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:6285"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:6285","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Corrosion of bipolar plates in PEM fuel cells","abstract":"Laboratory and synchrotron X-ray fluorescence (XRF) have been used to investigate the microscopic and macroscopic distribution of metallic contaminants in membrane electrode assemblies (MEAs) which were used in proton exchange membrane fuel cell (PEM FC) stacks. The laboratory XRF results were consistent with the synchrotron XRF results. Higher levels of contaminants observed for the areas near to the coolant outlet than the areas near to the coolant inlet. The cathode side of MEAs showed higher levels of contamination than the anode side of the MEAs. Synchrotron XRF maps of MEAs generally showed higher levels of contaminants on the cathode side compared with the anode side. Fe was mainly observed in the cathode side microporous layers, whereas Ni, Cr and Cu were mostly accumulated in the cathode side or in the membrane. Synchrotron XRF maps of MEA plan views showed a crack-like distribution for Fe and Pt which were similar to cracks in the microporous layer of the MEAs. A novel electrochemical cell that simulated galvanic and crevice corrosion, temperature cycles for a PEM fuel cell, and pressure across the stacks was designed and used to discriminate between the corrosion behaviour of candidate coatings for bipolar plates.","abstract_html":"Laboratory and synchrotron X-ray fluorescence (XRF) have been used to investigate the microscopic and macroscopic distribution of metallic contaminants in membrane electrode assemblies (MEAs) which were used in proton exchange membrane fuel cell (PEM FC) stacks. The laboratory XRF results were consistent with the synchrotron XRF results. Higher levels of contaminants observed for the areas near to the coolant outlet than the areas near to the coolant inlet. The cathode side of MEAs showed higher levels of contamination than the anode side of the MEAs. Synchrotron XRF maps of MEAs generally showed higher levels of contaminants on the cathode side compared with the anode side. Fe was mainly observed in the cathode side microporous layers, whereas Ni, Cr and Cu were mostly accumulated in the cathode side or in the membrane. Synchrotron XRF maps of MEA plan views showed a crack-like distribution for Fe and Pt which were similar to cracks in the microporous layer of the MEAs. A novel electrochemical cell that simulated galvanic and crevice corrosion, temperature cycles for a PEM fuel cell, and pressure across the stacks was designed and used to discriminate between the corrosion behaviour of candidate coatings for bipolar plates.","abstract_has_math":false,"creators":["Azimifar, Seyed Ali"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-12","date_published":"2015-12","updated_at":"2026-11-19T09:28:49Z","subjects":["TN Mining engineering. Metallurgy"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/6285/1/Azimifar15PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A6285","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["other"]},{"key":"dc:creator","label":"Author","values":["Azimifar, Seyed Ali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-12"]},{"key":"dc:date.issued","label":"Date","values":["2015-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/6285/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TN Mining engineering. Metallurgy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/6285/1/Azimifar15PhD.pdf","http://etheses.bham.ac.uk//id/eprint/6285/5/Decl_IS_Azimifar15PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Laboratory and synchrotron X-ray fluorescence (XRF) have been used to investigate the microscopic and macroscopic distribution of metallic contaminants in membrane electrode assemblies (MEAs) which were used in proton exchange membrane fuel cell (PEM FC) stacks. The laboratory XRF results were consistent with the synchrotron XRF results. Higher levels of contaminants observed for the areas near to the coolant outlet than the areas near to the coolant inlet. The cathode side of MEAs showed higher levels of contamination than the anode side of the MEAs. Synchrotron XRF maps of MEAs generally showed higher levels of contaminants on the cathode side compared with the anode side. Fe was mainly observed in the cathode side microporous layers, whereas Ni, Cr and Cu were mostly accumulated in the cathode side or in the membrane. Synchrotron XRF maps of MEA plan views showed a crack-like distribution for Fe and Pt which were similar to cracks in the microporous layer of the MEAs. A novel electrochemical cell that simulated galvanic and crevice corrosion, temperature cycles for a PEM fuel cell, and pressure across the stacks was designed and used to discriminate between the corrosion behaviour of candidate coatings for bipolar plates."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Corrosion of bipolar plates in PEM fuel cells"]}]}],"canonical_facts":{"dc:contributor.sponsor":["other"],"dc:creator":["Azimifar, Seyed Ali"],"dc:date":["2015-12"],"dc:date.issued":["2015-12"],"dc:description.abstract":["Laboratory and synchrotron X-ray fluorescence (XRF) have been used to investigate the microscopic and macroscopic distribution of metallic contaminants in membrane electrode assemblies (MEAs) which were used in proton exchange membrane fuel cell (PEM FC) stacks. The laboratory XRF results were consistent with the synchrotron XRF results. Higher levels of contaminants observed for the areas near to the coolant outlet than the areas near to the coolant inlet. The cathode side of MEAs showed higher levels of contamination than the anode side of the MEAs. Synchrotron XRF maps of MEAs generally showed higher levels of contaminants on the cathode side compared with the anode side. Fe was mainly observed in the cathode side microporous layers, whereas Ni, Cr and Cu were mostly accumulated in the cathode side or in the membrane. Synchrotron XRF maps of MEA plan views showed a crack-like distribution for Fe and Pt which were similar to cracks in the microporous layer of the MEAs. A novel electrochemical cell that simulated galvanic and crevice corrosion, temperature cycles for a PEM fuel cell, and pressure across the stacks was designed and used to discriminate between the corrosion behaviour of candidate coatings for bipolar plates."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/6285/1/Azimifar15PhD.pdf","http://etheses.bham.ac.uk//id/eprint/6285/5/Decl_IS_Azimifar15PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/6285/"],"dc:subject":["TN Mining engineering. Metallurgy"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Corrosion of bipolar plates in PEM fuel cells"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:28:49Z"}