{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:6321"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:6321","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Direct contact measurement of the dielectric properties of glass ionomer cements for MEMs design","abstract":"This investigation was aimed at measuring the changes in dielectric properties of glass ionomer cements during their setting reaction in order to observe if there is a correlation between these properties and the cement curing. Commercial glass ionomer cements were prepared and their setting process was monitored over a 24 hour period using FT-IR and direct contact impedance measurement. An impedance bridge with a dielectric test assembly, based on previous work by Braden et al, was used to measure the dielectric properties of a number of different glass ionomer cements using a simple design. Using the dielectric properties of the glass ionomer cements, it could be possible to develop a micro-electro-mechanical sensor (MEMS) based on this design, which could be implanted into a dental restoration and interrogated remotely. During the curing of the cements examined, the dielectric data collected from the co-planar assembly showed a change in impedance over the course of the setting of the cement, which when compared to FT-IR spectra over the same period, showed a correlation between the dielectric properties and the chemical changes within the cement.","abstract_html":"This investigation was aimed at measuring the changes in dielectric properties of glass ionomer cements during their setting reaction in order to observe if there is a correlation between these properties and the cement curing. Commercial glass ionomer cements were prepared and their setting process was monitored over a 24 hour period using FT-IR and direct contact impedance measurement. An impedance bridge with a dielectric test assembly, based on previous work by Braden et al, was used to measure the dielectric properties of a number of different glass ionomer cements using a simple design. Using the dielectric properties of the glass ionomer cements, it could be possible to develop a micro-electro-mechanical sensor (MEMS) based on this design, which could be implanted into a dental restoration and interrogated remotely. During the curing of the cements examined, the dielectric data collected from the co-planar assembly showed a change in impedance over the course of the setting of the cement, which when compared to FT-IR spectra over the same period, showed a correlation between the dielectric properties and the chemical changes within the cement.","abstract_has_math":false,"creators":["Boissonade, Jonathan James"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-12","date_published":"2015-12","updated_at":"2026-11-19T09:28:49Z","subjects":["QD Chemistry","RK Dentistry"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/6321/1/Boissonade15PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A6321","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["epsrc"]},{"key":"dc:creator","label":"Author","values":["Boissonade, Jonathan James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-12"]},{"key":"dc:date.issued","label":"Date","values":["2015-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/6321/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["QD Chemistry","RK Dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/6321/1/Boissonade15PhD.pdf","http://etheses.bham.ac.uk//id/eprint/6321/5/Decl_IS_Boissonade15PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This investigation was aimed at measuring the changes in dielectric properties of glass ionomer cements during their setting reaction in order to observe if there is a correlation between these properties and the cement curing. Commercial glass ionomer cements were prepared and their setting process was monitored over a 24 hour period using FT-IR and direct contact impedance measurement. An impedance bridge with a dielectric test assembly, based on previous work by Braden et al, was used to measure the dielectric properties of a number of different glass ionomer cements using a simple design. Using the dielectric properties of the glass ionomer cements, it could be possible to develop a micro-electro-mechanical sensor (MEMS) based on this design, which could be implanted into a dental restoration and interrogated remotely. During the curing of the cements examined, the dielectric data collected from the co-planar assembly showed a change in impedance over the course of the setting of the cement, which when compared to FT-IR spectra over the same period, showed a correlation between the dielectric properties and the chemical changes within the cement."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Direct contact measurement of the dielectric properties of glass ionomer cements for MEMs design"]}]}],"canonical_facts":{"dc:contributor.sponsor":["epsrc"],"dc:creator":["Boissonade, Jonathan James"],"dc:date":["2015-12"],"dc:date.issued":["2015-12"],"dc:description.abstract":["This investigation was aimed at measuring the changes in dielectric properties of glass ionomer cements during their setting reaction in order to observe if there is a correlation between these properties and the cement curing. Commercial glass ionomer cements were prepared and their setting process was monitored over a 24 hour period using FT-IR and direct contact impedance measurement. An impedance bridge with a dielectric test assembly, based on previous work by Braden et al, was used to measure the dielectric properties of a number of different glass ionomer cements using a simple design. Using the dielectric properties of the glass ionomer cements, it could be possible to develop a micro-electro-mechanical sensor (MEMS) based on this design, which could be implanted into a dental restoration and interrogated remotely. During the curing of the cements examined, the dielectric data collected from the co-planar assembly showed a change in impedance over the course of the setting of the cement, which when compared to FT-IR spectra over the same period, showed a correlation between the dielectric properties and the chemical changes within the cement."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/6321/1/Boissonade15PhD.pdf","http://etheses.bham.ac.uk//id/eprint/6321/5/Decl_IS_Boissonade15PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/6321/"],"dc:subject":["QD Chemistry","RK Dentistry"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Direct contact measurement of the dielectric properties of glass ionomer cements for MEMs design"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:28:49Z"}